ViziT BVD-411A Operating instructions

Category
Door intercom systems
Type
Operating instructions

This manual is also suitable for

BVD-411x
BVD-411x VIZIT
A
B
L
BVD-411x
(R)
(R)
FEATURES
V
С
VIZIT-ML400(S) VIZIT-ML300
VIZIT-KTM600М
VIZIT-KTM602М
VIZIT®
VIZIT
SAFETY INSTRUCTIONS
25
Doorstation is intended for operation in video doorphones.
The following models are available:
Abbreviations used in the models’ names:
audio doorstation
colour camera
- Board lens
- IR illumination for camera
For door opening with RF-keys, e are to
or
.
.
.
.
IR illumination for the camera.
Image auto switching from colour to B/W in dark environment.
-
-
Doorstation operates together with electromagnetic locks , . The product is
compatible with similar electromagnetic locks with impedance no less than 20-Ohm and a built-in degaussing module.
Electromechanical locks with impedance no less than 10-Ohm can be used as well.
lectromagnetic locks be used together with Keys Controller
.
Subscriber devices are products :
- apartment handsets(UKPs);
- monitors of Series 400.
Calls to the subscriber by pressing the button.
Abeep at the doorstation and apartment handset / monitor when the button is pressed.
Duplex intercom
Door zone video monitoring
Door unlocking by pressing the button on the apartment handset / monitor
Abeep indicates door lock release
The product does not contain voltage above .
Do not make any connections or repair when the power is on.
Take care not to spill any liquids or chemically active substances on the product.
Switch the power off, before cleaning the doorstation. Clean by wiping with dry soft cloth. Do not use any liquid cleaners,
aerosol cleaners or abrasive agents.
·
·
·
·
·
·
·
·
1 -Figure Doorstation BVD-411x
1
2
3 4
5
5Speaker
4CALL button
3Microphone
1Camera
(BVD-411CBL)
2IR LEDs (6)
Model
BVD 11A-4
Colour camera
Board lens
Illumination
for camera
BVD 11CBL-4
INSTALLATION
Before mounting, examine carefully the operating instruction for the installation order and wiring diagrams.
The doorstation is mounted on a wall entrancenear the , using the bracket and screws supplied.
PARTS LIST
Screw М4х8
Screw 2 - 4х25 Concrete Insert 6х30
BVD-411x Operating Instruction
x1
x1
Mounting Parts
x2
x2 x2
Gag
x 4
Bracket
x1
Figure Doorstation mounting on a wall2-
35
2
70
107
12
22
55
Locate the doorstation to avoid:
- direct rays of the sun or other light sources
- direct hit of rain and snow
To reduce possibility of external noises influence on image, use 75-Ohm coaxial cable for video circuits.
Figure Terminals and their destination3 -
Coax cable
holder
L N
GND
IE
Ev
-
-
-
intercom line
ground
supply voltage for doorstation
- supply voltage for outdoor camera
(for BVD-411A)
VO
Еc
LC
-
-
-
video out (for BVD-411CBL)
supply voltage for built-in camera
lock control
Terminals:
Figure Recommended doorstation position
and camera field of view
4 -
150 cm
50 cm
50 cm
68°
WIRING DIAGRAMS
Figure Doorstation with Apartment
Handset
5 - BVD-411A
UKP-12(M)
25 50 100
0.2 0.4 0.8
0.8 1.5
Cross-section, mm2
Cable
0.4
A
C+D
Length, m
0.2 0.4 0.8B
UKP-12(M)
Power Supply
BPD18/12-1-1
-18
+18
+12
-12
1
2
1
2
2
1
1
2
12
A
B
C
D
1
2
+
-
1
2
2
1
V
1A
50
ELECTROMECHANICAL
LOCK R 10 O )(hm
LINE
GND
+E
Ev
Ec
LC
Doorstation
BVD 411A-
Figure 6 Doorstation with Outdoor Camera,
Monitor and
Electromechanical Lock
-BVD-411A
VIZIT-M430C (VIZIT-M456C)
Outdoor camera (current consumption 100 mA max.)
-18
+18
+12
-12
LN-
GND
LN+
VI1
+E
DATA
Ec1
Ec2
GND
VI2
3
4
1
2
2
1
1
2
12
A
B
C
D
1
3
4
12
2
1
2
VO
Ec
VG
1
2
E
1
2
2
1
V
1A
50
25 50 100
0.2 0.4 0.8
0.8 1.50.4
A+B+E
C+D
Cross-section, mm2
Cable Length, m
LINE
GND
+E
Ev
Ec
LC
Power Supply
BPD18/12-1-1
Doorstation
BVD 411A-
ELECTROMECHANICAL
LOCK R 10 O )(hm
- 430
Monitor
VIZIT M C
(VIZIT-M456C)
-18
+18
+12
-12
LN-
GND
LN+
VI1
+E
DATA
Ec1
Ec2
GND
VI2
25 50 100
0.2 0.4 0.8
0.8 1.5
1
2
3
4
5
1
2
2
1
1
2
12
2
1
A
B
C
D
0.4
A+B
C+D
1
2
3
4
5
12
Power Supply
BPD18/12-1-1
Cross-section, mm2
Cable Length, m
50V
1A
LINE
GND
+E
VO
Ec
LC
Doorstation
BVD 411CBL-
Figure 7 Doorstation with Monitor
and
Electromechanical Lock
-BVD-411CBL
VIZIT-M430C (VIZIT-M456C)
ELECTROMECHANICAL
LOCK R 10 O )(hm
- 430
Monitor
VIZIT M C
(VIZIT-M456C)
Figure 8 Doorstation with Control Unit
Reader , Monitor
Electromagnetic Lock and Button
-
,
BVD-411CBL KTM602M
RD-3 VIZIT-M4
VIZIT-ML400 EXIT 300
30С (VIZIT-M456C)
-DL
+DL
BIP
ELC
RD
GND
OP
LN-
GND
LN+
VI1
+E
DATA
Ec1
Ec2
GND
VI2
1
2
3
4
22
2
2
1
1
5
1
B
1
2
3
4
5
1
2
A
D
C
5
1
2
4
4
3
3
1
12
2
E
21
2
1
5
LINE
GND
+E
VO
Ec
LC
Reader
RD-3
Black
White
Blue
Red
Electromagnetic
lock VIZIT-ML400
Green
Button
EXIT 300
Black
White
Blue
Red
- 430
Monitor
VIZIT M C
(VIZIT-M456C)
Control Unit
KTM602М
25
0.2 0.4
0.80.4
A+B
C
50
0.2 0.4D+E
Cross-section, mm
Cable Length, m
2
Doorstation
BVD 411CBL-
1
FUNCTIONAL CHECK AND OPERATIN ORDER
Note:
(60 ± 5)
16...25
3
0103
0.
OPERATING CONDITIONS
- 40°C 45°C
- 30°C 45°C
98% 25°C
G
SPECIFICATIONS
VDC
Wmax
mm 745
kg 3
+
+
Before switching the power on, verify all electric connections.
Turn the Power Supply on.
Press the button on the doorstation. A beep sounds both at the doorstation and monitor / apartment handset while the
button remains pressed, image appears on the monitor’s screen.
Pick up the handset and check duplex intercom. Check image on the screen. Adjust brightness, contrast and
saturation, if needed.
Press the button on the monitor / apartment handset to release the door lock. The doorstation produces a eep and
the lock stays released while the button remains pressed. Release the button to return to intercom mode.
Hang up the handset. The system goes to stand-by mode.
When called, subscriber can press the button without picking up the handset to release the door
lock.The system returns to stand-by mode when the button is released.
ntercom is availabl within seconds after picking up the handset. If the handset is not picked up in 60 seconds,
the system returns to stand-by mode automatically
subscriber can activate door zone video monitoring at any time (
. The built-in camera or outdoor one provide video signal for the monitor.
During video monitoring subscriber can also activate duplex intercom by picking up the handset. The system returns
o stand-by mode hanging up the handset automatically in 60 seconds.
Dimensions (W)x(H)x(D)
amera parameters are given below:
Ambient temperature rang :
- -41
- -411
Relative humidity of ai
unit
monitor’s
b
the
the
the monitor’s
the
Ie
the .
The for details, please refer to the operating instruction
on your monitor)
the
t with , or
Operating voltage,
Power consumption,
,xx
Weight,
The built-in c
e
BVD to
BVD CBL to
r: up to at
Camera parameters
Lens
Angle of view (diagonal)°
Colour system
Scanning system
Resolution, TVL
Output voltage,
at 75 OhmVp-p
Doorstation BVD 1 CBL-4 1
PAL
СCIR
0.1
1 ± 0.15
Board
Minim illumination of an
object at 50 cm distance from
the camera,
al
Lux
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

ViziT BVD-411A Operating instructions

Category
Door intercom systems
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI