SAFETY INSTRUCTIONS
18 VDC
INSTALLATION
ATTENTION!
1
23
4 5 6
EXIT
Attention! 10 Ohms
20 Ohms
4 - 6
The doorstation does not contain voltage above .
Connect the grounding wire of the doorstation to the protective ground.
To avoid damage do not make any connections or repair when the power is on.
To maximize the reliability of this product, do not expose it to rain, snow and direct sun rays!
Before mounting, examine carefully the operating instruction for installation order and wiring diagrams.
Doorstation mounting dimensions are given on Figure .
Fix the doorstation on a door (Figure ) or on a wall (Figure ) using the screws supplied.
Drive the gags from the mounting kit into mounting holes.
Perform all connections according to the examples of wiring diagrams on Figures , and .
Recommended cross-sections of wires are given in Control Unit operating instruction.
To ensure door opening from the inside, the button is to be installed inside the building near the door. Dispose
commutators at building floors in wall recesses near a ceiling, if it's possible. Handsets and monitors should be
installed in apartments.
Electromechanical lock impedance should be min. .
Electromagnetic lock impedance should be min. .
If an electromechanical lock is used, a damper diode (50V/1A, not supplied) is to be connected to the lock
terminals.
Abbreviations used on Figures :
VO VIDEO OUT
VG VIDEO GROUND
CUD Control Unit Data
DSD Doorstation Data
+Е Doorstation Power
MIC Microphone
SP Speaker
ТМ TM-reader signal
GND GROUND
OP OPEN
+DL + Door Lock
-DL - Door Lock
LN Intercom line
Еk Code and power for commutators
SEL (SELECT)