Specifications
Operating Voltage:12~24VDC
Current Draw: Pull in 40mA/12VDC; Holding 30mA/12VDC
Sensor Range: 1”~6” (3~15cm) (±10%)
Relay Rating: 1A/30VDC maximum
Operating Temperature: -10~+70ºC
Ambient Humidity: 5~95%
Dual LED, illuminated sensor indicates status:
Standby (Red), Active (Green)
Output Time: 0.5~20 seconds, toggle
*Toggle: turn all the way clockwise
Faceplate Finish: Stainless steel
Pull in 50mA/24VDC; Holding 25mA/24VDC
Adjusting Sensor Range & Trigger Time
5 PIN
Trigger time
(door opening time)
adjustment
Note: Adjusting door opening time to maximum
(turning all the way to the right) will set the switch
to toggle mode.
Sensor range
adjustment
FarNear Short Long
RTS Series Wave Sense Infrared Exit Devices
Installation Instructions
RTS-700
RTS-800
RTS-8585
3.37”
(85.5mm)
2.36”
(60mm)
3.37”
(85.5mm)
2.74”
(69.5mm)
3.29”
(83.5mm)
4.49”
(114mm)
3.46”
(88mm)
3.46”
(88mm)
Side View
11.81”
(300mm)
1.38”
(Ø35mm)
0.83”
(21mm)
0.16”
(4mm)
Black
Red
Yellow
Green
Blue
(-)
(+)
(N.C.)
(COM.)
(N.O.)
0.73”
(18.5mm)
Side View
0.08”
(2mm)
11.81”
(300mm)
1.38”
(Ø35mm)
Black
Red
Yellow
Green
Blue
(-)
(+)
(N.C.)
(COM.)
(N.O.)
0.24”
(6mm)
0.1”
(2.5mm)
Side View
Black
Red
Yellow
Green
Blue
(-)
(+)
(N.C.)
(COM.)
(N.O.)
11.81”
(300mm)
0.87”
(Ø22mm)
RTS-700/800/8585
Wiring Diagrams
The RTS series wave sense infrared exit device includes one set of output contacts NC/NO/COM. It can directly control
electrical devices (e.g. electrified locks) or works with digital keypads or proximity readers. Please refer to the wiring
instructions below.
In Figure A, the RTS series
connects to the Request-to-Exit
input terminal of the access
control system. Relay output time
can be reduced to a minimum of
0.5 seconds.
In Figure B, the RTS series
controls a fail-safe locking device.
If it controls a fail-secure lock,
connect to the NO contact. Relay
output time is door opening time.
Caution:
Figure A
Keypad
Proximity Reader
Power Supply
12VDC
Electrified Lock
(Fail-safe)
N.O.
COM.
N.C.
PB
Side View
Black(-)
Red(+)
Yellow (N.C.)
Green(COM.)
Blue(N.O.)
Power Supply
12VDC
Electrified Lock
(Fail-safe)
Side View
Black(-)
Red(+)
Yellow(N.C.)
Green(COM.)
Blue(N.O.)
Figure B
To avoid wire burning, do not
exceed maximum relay
rating: 1A/30VDC.
Copyright
©
All Rights Reserved. P-MU-RTS-700-800 Published: 2020.06.05
  • Page 1 1
  • Page 2 2

Gianni Industries RTS-8585 Installation guide

Category
Security device components
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI