  • Hello! I'm your chat assistant, and I've thoroughly reviewed the installation instructions for the HK Instruments CDT2000 Duct series carbon dioxide transmitters, including models like the CDT2000-DC Duct. This document provides details on installation, wiring, and configuration, covering features like NDIR CO2 measurement, temperature monitoring, and automatic self-calibration. I'm here to help answer any questions you have about this device.
  • What does the CDT2000 Duct series measure?
    What is the automatic calibration method used by the CDT2000 Duct series?
    Where are CDT2000 Duct series devices commonly used?
    What is the CO2 measurement range of the CDT2000 Duct series?
Copyright HK Instruments 2022 www.hkinstruments. Installaon version 8.0 2022
INSTALLATION
INSTRUCTIONS
CARBON DIOXIDE TRANSMITTERS
CDT2000 Duct Series
READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS
DEVICE.
• Failuretoobservesafetyinformaonandcomplywith
instruconscanresultinPERSONALINJURY,DEATHAND/OR
PROPERTY DAMAGE.
• Toavoidelectricalshockordamagetoequipment,disconnect
powerbeforeinstallingorservicinganduseonlywiringwith
insulaonratedforfulldeviceoperangvoltage.
• Toavoidpotenalreand/orexplosiondonotuseinpotenally
ammableorexplosiveatmospheres.
• Retaintheseinstruconsforfuturereference.
• Thisproduct,wheninstalled,willbepartofanengineered
systemwhosespecicaonsandperformancecharacteriscs
arenotdesignedorcontrolledbyHKInstruments.Review
applicaonsandnaonalandlocalcodestoassurethatthe
installaonwillbefunconalandsafe.Useonlyexperiencedand
knowledgeabletechnicianstoinstallthisdevice.
SPECIFICATIONS
Thank you for choosinganHKInstruments CDT2000 Ductseries
carbon dioxide transmier. The CDT2000 Duct series is intended
foruseincommercialenvironmentsinHVAC/Rapplicaons.
TheCDT2000Ductseriesmeasurescarbondioxide(CO2),ulizing
theindustrystandardNDIRmeasurementprinciple,andtempera-
ture(T).Illuminateddisplayensureseasyreadabilityalsofromadis-
tance.TheCDT2000Ducthasascrewlesslidandaneasilyadjust-
ablemounngangethatmaketheinstallaonofthedeviceeasy.
TheCDT2000 Duct series transmierscalibratethemselves auto-
macallyusingABCTMlogic.TheABCTMlogicrequiresthatthespace
inwhichthetransmierisusedneedstotobeunoccupiedforfour
hours per day so that the indoor CO2 concentraon drops to the
outside level. CDT2000-DC Duct is a dual channel model with a
measuringchannelandareferencechannelthatmakesaconnuous
comparisonandthenecessaryadjustmentaccordingly.CDT2000-
DCDuctisalsosuitableforbuildingsthatareconnuouslyoccupied.
CDT2000Ductseriesdevicesarecommonlyusedtomonitor:
CO2levelsofincomingandreturnairinvenlaonsystem
•CDT2000-DCDuctseriesdevicescanalsobeusedinapplicaons
wherethereisaconstantsourceofcarbondioxidepresent(for
examplehospitalsandgreenhouses)
SPECIFICATIONS
Performance
Measurement ranges:
CO2:400–2000ppm
Temperature:0...50°C
Accuracy:
CO2:±40ppm+3%ofreading,DCmodel:75ppmor
10%ofreading(whicheverisgreater)
Temperature:<0.5ºC
Technical Specicaons
Media compability:
Dryairornon-aggressivegases
Measuring units:
ppmand°C
Measuring element:
CO2:Non-dispersiveinfrared(NDIR)
Temperature:NTC10k
Calibraon:
Automacself-calibraonABCLogicTMorconnuous
comparison(DC)
Environment:
Operangtemperature:0...50°C
Storagetemperature:-20...70°C
Humidity:0to95%rH,noncondensing
Physical
Dimensions:
Case:119x95.5x45mm
Probe:L=186mm,d=12mm
Mounng:
Withange,adjustable40...155mm
Weight:
150g
Materials:
Case:ABS
Cover:PC
Probe:ABS
Protecon standard:
IP54
Electrical connecons:
4springloadedterminals
(24V,GND,CO2, T)
0.2–1.5mm2(16–24AWG)
A-model:
6springloadedterminals
(24V,GND,Voltage_CO2,Voltage_T,
mA_CO2,mA_T)
0.2-1.5mm2(16-24AWG)
Electrical
Supplyvoltage:24VACorVDC±10%
Currentconsumpon:max230mA(at24V)+35mA
foreachvoltageoutput
Outputsignals
0/2...5/10VDC,LoadRminimum1kΩ
OnlyA-model:
4...20mA,LoadRmaximum500Ω,minimum20Ω
Outputcalibratedwithin±0.08mA
Conformance
Meetsrequirementsfor:
CE:  UKCA:
EMC:  2014/30/EU S.I.2016/1091
RoHS:  2011/65/EU S.I.2012/3032
WEEE:  2012/19/EU S.I.2013/3113
INTRODUCTION
APPLICATIONS
WARNING
RoHS
COMPLIANT
Copyright HK Instruments 2022 www.hkinstruments. Installaon version 8.0 2022
Schematics
dimensional drawings
INSTALLATION
STEP 1: MOUNTING THE DEVICE
1)Mountthedeviceinthedesiredlocaon(seestep1).
2)Routethecablesandconnectthewires(seestep2).
3)Thedeviceisnowreadyforconguraon.
WARNING!Applypoweronlyaerthedeviceisproperlywired.
1)Selectthemounnglocaon(onaduct).
2)Usethemounngangeofthedeviceasatemplateandmarkthe
screwholes.
3)Mounttheangeontheductwithscrews(notincluded).(Figure1a)
4)Adjusttheprobetothedesireddepth.Ensurethattheendofthe
probereachesthemiddleoftheduct.(Figure1b)
5)Tightenthescrewontheangetoholdtheprobeinposion.
119.0
95.5
119.0
45.0
88.5
186.0
Figure 1a - Mounng a ange
Figure 1b - Mounng the probe in a ange
Air flow direcon Air flow direcon
Air flow direcon Air flow direcon Air flow direcon
Strain relief facing down
Figure 1c - Mounng orientaon
Display connecon
TE
24 V
GND
Joysck 1
Joysck 2
Joysck 3
Select
Up
Down
Menu buons CO2/RH
mA Out (oponal)
CO2/RH
TE
Tighten the
screw
Copyright HK Instruments 2022 www.hkinstruments. Installaon version 8.0 2022
STEP 3: CONFIGURATION
ConguraonoftheCDT2000Ductseriesdeviceconsistsof:
Conguraonmenuopons.(Displayversionsonly.)
Presstheselectbuontoacceptchanges.Movetothenextset-
ngbypressingthedownbuon.
1)AcvatethedeviceMenubypushingtheselectbuonfor2
seconds.
ForCEcomplianceaproperlygroundedshieldingcableis
required.
1)Unscrewthestrainreliefandroutethecable(s).
2)Connectthewiresasshowningure2a.
3)Tightenthestrainrelief.
CO2
T
24 V
GND
+ Power Supply
24VDC / 24VAC
Output 0/2...5/10 V
Output 0/2...5/10 V
CO2
T
Output 4...20 mA
Output 4...20 mA Oponal mA output
3)SelecttheCO2highlimitforoutputband:500...2000ppm.
CO2 OUT MAX
2000 CO
2 ppm
SELECT
UP
DOWN
4)Selectthetemperaturelowlimitforoutputband:0...45.0°Cor
32...112°F.
TE OUT MIN
0.0 °C
SELECT
UP
DOWN
5)Selectthetemperaturehighlimitforoutputband:5...50.0°C
or42...122°F.
6)Selecttheoutputmaximumvoltage:5V/10V.
NOTE!WhenusingmAoutputs,10Vmustbeselected.
TE OUT MAX
50.0 °C
SELECT
UP
DOWN
MAX OUTPUT V
10 V
SELECT
UP
DOWN
7)Selecttheoutputminimumvoltage:0V/2V.
NOTE!WhenusingmAoutputs,0Vmustbeselected.
MIN OUTPUT V
0 V
SELECT
UP
DOWN
STEP 2: WIRING DIAGRAMS
NOTE!Whenusinglongconneconwiresitmaybenecessarytousea
separateGNDwireforvoltageoutputcurrenttopreventmeasurement
distoron.TheneedforanextraGNDwiredependsonthecrosssec-
onandlengthoftheusedconneconwires.Iflongand/orsmallcross
seconwiresareused,supplycurrentandwireresistancemaygener-
ate avoltage drop in the common GND wire resulng ina distorted
outputmeasurement.
CO2
T
24 V
GND
+Power Supply
24VDC / 24VAC
Output 0/2...5/10 V
Output 0/2...5/10 V
V
V
Figure 2a - Wiring diagram
Figure 2b - Wiring diagram: Extra GND wire
CONFIGURATION CONTINUED
10)Pushtheselectbuontoexitmenu.
SELECT
EXIT MENU SELECT
8)SelectCO2oset:±200CO2ppm,Osetfeatureenables
eldcalibraon.Thisisnecessaryindemandingapplicaons
requiringannualcalibraon.
CO2 OFFSET
0 CO
2ppm
SELECT
UP
DOWN
9)Selecttemperatureoset:±5°Cor±9°F
TE OFFSET
0.0 °C
SELECT
UP
DOWN
CO2 OUT MIN
400 CO
2 ppm
SELECT
UP
DOWN
2)SelecttheCO2lowlimitforoutputband:0...1900ppm.
Copyright HK Instruments 2022 www.hkinstruments. Installaon version 8.0 2022
WARRANTY POLICY
Thesellerisobligatedtoprovideawarrantyofveyearsforthedeliv-
eredgoodsregardingmaterialandmanufacturing.Thewarrantyperiod
isconsideredtostartonthedeliverydateoftheproduct.Ifadefect
inrawmaterialsoraproduconawisfound,thesellerisobligated,
whentheproductissenttothesellerwithoutdelayorbeforeexpira-
onofthewarranty,toamendthemistakeathis/herdiscreoneither
by repairing the defecve product or by delivering free of charge to
thebuyeranewawlessproductandsendingittothebuyer.Delivery
costsfortherepairunderwarrantywillbepaidbythebuyerandthe
return costs by the seller. The warranty does not comprise damages
causedbyaccident,lightning,oodorothernaturalphenomenon,nor-
malwearandtear,improperorcarelesshandling,abnormaluse,over-
loading,improperstorage,incorrectcareorreconstrucon,orchanges
and installaonworknotdoneby theseller.Theseleconofmateri-
alsfordevicespronetocorrosionisthebuyer’sresponsibility,unless
otherwise is legally agreed upon. Should the manufacturer alter the
structureofthedevice,thesellerisnotobligatedtomakecomparable
changestodevicesalreadypurchased.Appealingforwarrantyrequires
thatthebuyerhascorrectlyfullledhis/herduesarisenfromthede-
liveryandstatedinthecontract.Thesellerwillgiveanewwarrantyfor
goodsthathavebeenreplacedorrepairedwithinthewarranty,how-
everonlytotheexpiraonoftheoriginalproduct’swarrantyme.The
warrantyincludestherepairofadefecvepartordevice,orifneeded,
anewpartordevice,butnotinstallaonorexchangecosts.Underno
circumstanceisthesellerliablefordamagescompensaonforindirect
damage.
RECYCLING/DISPOSAL
The parts le over from installaon should be
recycled according to your local instrucons.
Decommissioned devices should be taken to a
recyclingsitethatspecializesinelectronicwaste.
/