Fiberplex CMP-530 User manual

Category
Chassis components
Type
User manual

USERMANUAL
TIA‐530/MIL‐188‐114OscilloscopeMonitorPanel
CMP‐530
WarningforYourProtection
1.Readtheseinstructions.
2.Keeptheseinstructions.
3.Heedallwarnings.
4.Followallinstructions.
5.Donotusethisapparatusnearwater.
6.Cleanonlywithadrycloth.
7.Donotblockanyoftheventilationopenings.Installinaccordancewiththemanufacturer’sinstructions.
8.Donotinstallnearanyheatsourcessuchasradiators,heatregisters,stoves,orotherapparatus(includingamplifiers)thatproduceheat.
9.Donotdefeatthesafetypurposeofthepolarizedorgrounding‐typeplug.Apolarizedplughastwobladeswithonewiderthantheother.A
groundingtypeplughastwobladesandathirdgroundingprong.Thewidebladeorthethirdprongisprovidedforyoursafety.Iftheprovidedplug
doesnotfitintoyouroutlet,consultanelectricianforreplacementoftheobsoleteoutlet.
10.Protectthepowercordfrombeingwalkedonorpinched,particularlyatplugs,conveniencereceptacles,andthepointwheretheyexitfromthe
apparatus.
11.Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
12.Useonlywiththecart,stand,tripod,bracket,ortablespecifiedbythemanufacturer,orsoldwiththeapparatus.Whenacartisused,use
cautionwhenmovingthecart/apparatuscombinationtoavoidinjuryfromtip‐over.
13.Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
14.Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushasbeendamagedinanyway,suchaspower‐supply
cordorplugisdamaged,liquidhasbeenspilledorobjectshavefallenintotheapparatus,theapparatushasbeenexposedtorainormoisture,does
notoperatenormally,orhasbeendropped.
Theapparatusshallnotbeexposedtodrippingorsplashing.Noobjectsfilledwithliquids,suchasvasesordrinkcups,shallbeplacedonthe
apparatus.
“WARNING:Toreducetheriskoffireorelectricshock,donotexposethisapparatustorainormoisture.”
GeneralInstallationInstructions
Pleaseconsiderthesegeneralinstructionsinadditiontoanyproduct‐specificinstructionsinthe“Installation”chapterofthismanual.
Unpacking
Checktheequipmentforanytransportdamage.Iftheunitismechanicallydamaged,ifliquidshavebeenspilledorifobjectshavefallenintothe
unit,itmustnotbeconnectedtotheACpoweroutlet,oritmustbeimmediatelydisconnectedbyunpluggingthepowercable.Repairmustonlybe
performedbytrainedpersonnelinaccordancewiththeapplicableregulations.
InstallationSite
Installtheunitinaplacewherethefollowingconditionsaremet:
Thetemperatureandtherelativehumidityoftheoperatingenvironmentmustbewithinthespecifiedlimitsduringoperationofthe
unit.Valuesspecifiedareapplicabletotheairinletsoftheunit.
Condensationmaynotbepresentduringoperation.Iftheunitisinstalledinalocationsubjecttolargevariationsofambient
temperature(e.g.inanOB‐van),appropriateprecautionsmustbetaken.
Unobstructedairflowisessentialforproperoperation.Ventilationopeningsoftheunitareafunctionalpartofthedesignandmust
notbeobstructedinanywayduringoperation(e.g.‐byobjectsplaceduponthem,placementoftheunitonasoftsurface,or
improperinstallationoftheunitwithinarackorpieceoffurniture).
Theunitmustnotbeundulyexposedtoexternalheatsources(directsunlight,spotlights).
AmbientTemperature
UnitsandsystemsbyFiberPlexaregenerallydesignedforanambienttemperaturerange(i.e.temperatureoftheincomingair)of+5...+40°C.
Whenrackmountingtheunits,thefollowingfactsmustbeconsidered:
Thepermissibleambienttemperaturerangeforoperationofthesemiconductorcomponentsis0°Cto+70°C(commercial
temperaturerangeforoperation).
Theairflowthroughtheinstallationmustallowexhaustairtoremaincoolerthan70°Catalltimes.
Averagetemperatureincreaseofthecoolingairshallbeabout20C°,allowingforanadditionalmaximum10C°increaseatthe
hottestcomponents.
Ifthecoolingfunctionoftheinstallationmustbemonitored(e.g.forfanfailureorilluminationwithspotlamps),theexhaustairtemperaturemust
bemeasureddirectlyabovethemodulesatseveralplaceswithintheenclosure.
GroundingandPowerSupply
Groundingofunitswithmainssupply(classIequipment)isperformedviatheprotectiveearth(PE)conductorintegratedinthreepinPhoenix™
connector.Unitswithbatteryoperation(<60V,classIIIequipment)mustbeearthedseparately.Groundingtheunitisoneofthemeasuresfor
protectionagainstelectricalshockhazard(dangerousbodycurrents).Hazardousvoltagemaynotonlybecausedbydefectivepowersupply
insulation,butmayalsobeintroducedbytheconnectedaudioorcontrolcables.
Thisequipmentmayrequiretheuseofadifferentlinecord,attachmentplug,orboth,dependingontheavailablepowersourceatinstallation.If
theattachmentplugneedstobechanged,referservicingtoqualifiedpersonnel.
Warranty,ServiceandTermsandConditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsof
Sale’.Thisdocumentisavailableonfiberplex.comorcanbeobtainedbyrequestingitfrom
[email protected]orcalling301.604.0100.
Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterial
canberecycled.Recyclingpackingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedto
disposeofthetransportpackingmaterials,recyclingisencouraged.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellassubstancesthatmustbedisposedof
professionally.Pleasedisposeofusedequipmentviaanauthorizedspecialistdealerorviathepublicwaste
disposalsystem,ensuringanymaterialthatcanberecycledhasbeen.Pleasetakecarethatyourused
equipmentcannotbeabused.Afterhavingdisconnectedyourusedequipmentfromthemainssupply,make
surethatthemainsconnectorandthemainscablearemadeuseless.
Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeof
publication.However,noliabilityisassumedbyFiberPlexforinaccuracies,errors,oromissions,norforlossor
damageresultingeitherdirectlyorindirectlyfromuseoftheinformationcontainedherein.

Introduction
TheCMP‐530connectsbetweentheDCEandDTEofTIA‐530orMIL‐188‐114balancedserialinterfaces,
allowingconnectionoflowimpedancetestequipmentsuchasoscilloscopesforanalogsignalanalysisofthe
digitalsignalinterfaceswithoutloadingtheinterfaces.AthirdDB‐25interfaceallowsconnectionofotheruser
equipmentdirectlytotheinterfaceconnections.
All25pinsbetweentheDCEandDTEinterfacesarepassedthroughthedevicepassively,sotheconnected
communicationinterfaceoperatesevenwithnopowerappliedtotheCMP‐530.Highimpedancebuffers
recreatethesignalslevelsonfour50ohmBNCoutputjacksallowingtheusertomonitorandtroubleshootthe
ReceiveData(RD)andReceiveTiming(RT)linesfromtheDCE,theTransmitData(TD)fromtheDTEaswellas
eithertheSendTiming(ST)fromtheDCEorTerminalTiming(TT)fromtheDTE(switchselectable),supporting
allsynchronoustimingconfigurations.
FrontpanelswitchesassociatedwitheachBNCselectadifferentialanalysis(A+B)ortheindividualAorBleads
ofeachsignal.
LoadingonTD,RD,RT,TT,andSTsignalsforlevelsbetween‐12and+12voltsisgreaterthan100kohms.For
signalsoutsideoftheselimits,diodeprotectiondeviceswillloadwith1kohmstotherespectiveexceeded
voltageontheparticularline.AllothersignalsontheinterfacearenotusedbytheCMP‐530andhaveno
loading.
ThefrontpanelDB‐25monitorporthasnobufferingorprotectiondevicesandisdirectlyconnectedtotheTD,
TT,RD,RTandSTlinesbetweentheDCEandDTEconnectors.Theusermustensureanyconnecteddevicesdo
notadverselyaffecttheequipmentconnectedtotheDCEorDTEinterfaces,oranyexpectedmeasurementat
theBNCoutputs.Noothersignalsareavailableonthefrontpanelmonitorport.
KeyFeatures
CompliantwithEIA‐530interfacespecifications.
Monitoredsignals;SendData,SendTiming,ReceiveData,ReceiveTiming.Bothlinesof
eachbalancedcircuitareavailableformonitoringsignalquality.
AselectorswitchallowsoscilloscopemonitoringofeithertheSendTiming,orthe
TerminalTimingsignalpath.
AnotherselectorswitchallowsviewingoftheAlead,theBlead,ortheA+Bsignals.
GettingStarted
InitialInspection
Immediatelyuponreceipt,inspecttheshippingcontainerfordamage.Thecontainershouldberetaineduntil
theshipmenthasbeencheckedforcompletenessandtheequipmenthasbeencheckedmechanicallyand
electrically.Iftheshipmentisincomplete,ifthereismechanicaldamage,oriftheunitfailstooperatenotify
FiberPlexandmaketheshippingmaterialsavailableforthecarrier'sinspection.
Features
Figure1:CMP‐530FrontPanel
ExternalMonitorPort–DB‐25connectorforconnectionofotheruserequipmentformonitoring.See
pinoutsbelow.
TT/STSelectorSwitch–Two(2)positiontoggleswitch.SelectsbetweenTerminalTimingandSend
TimingtobepresentedonadjacentBNC.
SignalSelectionSwitch–Three(3)positiontoggleswitch.Usedtoselectadifferential
analysis(A+B)ortheindividualAorBleadsofeachsignal.
TT/STSignalConnector–BNCconnector,50ohm.
ReceiveTimingSignalConnector–BNCconnector,50ohm.
SendDataSignalConnector–BNCconnector,50ohm.
ReceiveDataSignalConnector–BNCconnector,50ohm.
PowerIndicator–LEDilluminateswhentheunitisenergized.
Figure2:CMP‐530RearPanel
DCEConnector–DB‐25connector.Seepinoutsbelow.
DTEConnector–DB‐25connector.Seepinoutsbelow.
PowerConnector–3ProngACconnector,typeIEC‐320C‐14.
12345678910 11
12 13 13
2
3
6
12
5
13
14
7
4
8
9
10
11
1
PINOUTS
Pin ToDCE ToDTE ExternalMonitor EIA‐530Designation
1  ChassisGround
7  SignalGround
2 Out In Out SendDataA(SD)
14 SendDataB(SD\)
3 In Out Out ReceiveDataA(RD)
16 ReceiveDataB(RD\)
4 Out In N/C RequestToSendA(RTS)
19 N/C RequestToSendB(RTS\)
5 In Out N/C ClearToSendA(CTS)
13 N/C ClearToSendB(CTS\)
20 Out In N/C TerminalReadyA(TR)
23 N/C TerminalReadyB(TR\)
6 In Out N/C DataSetReadyA(DSR)
22 N/C DataSetReadyB(DSR\)
24 Out In Out TerminalTimingA(TT)
11 TerminalTimingB(TT\)
17 In Out Out ReceiveTimingA(RT)
9 ReceiveTimingB(RT\)
15 In Out Out SendTimingA(ST)
12 SendTimingB(ST\)
8 In Out N/C ReceiverReadyA(RR)
10 N/C ReceiverReadyB(RR\)
18 Out In N/C LocalLoopback(LL)
25 In Out N/C TestMode(TM)
21 Out In  RemoteLoopback(RL)
FunctionalDiagram
SD SD
+
-+
-
RD RD
+
-+
-
TT TT
+
-+
-
ST ST
+
-+
-
RT RT
+
-+
-
SD RD TT/ST RT
External Monitor
To DTE
To DCE
SD
+
-
-
+
RD
+
-
-
+
TT
+
-
-
+
ST
+
-
-
+
RT
+
-
-
+
A-(A+B)-B
TT/ST
Specifications
Figure3CMP‐530Dimensions
PHYSICALSPECIFICATIONS
Length Width Height Weight
CaseDimensions(Unloaded) 11.3in
(286mm)
19.0in
(483mm)
1.72in
(43.7mm)
10.5lb
(4.8kg)
ELECTRICALSPECIFICATIONS
Min Typ Max Units
PowerRequirement VoltageRange 100 115/230 240 VAC
PowerLineFrequency 47 60/50 63 Hz
PowerConsumption ‐ ‐ 10 W
SignalSpecifications BNCOutputLevels ‐12 ‐ 12 V
MaximumDigitalRate ‐ 5 ‐ MHz
AnalogBandwidth 10MHz,‐3dBmaxfromactualDCEorDTEsignal
PowerConnectorType IEC‐320C‐14
Fuse 1A250VSLO‐BLO,5x20mm
18.33
[465.5]
18.33
[465.5]
19.00
[482.6]
19.00
[482.6]
1.25
[31.8]
1.25
[31.8]
1.72
[43.7]
1.72
[43.7]
10.01
[254.1]
10.01
[254.1]
11.27
[286.3]
11.27
[286.3]
17.33
[440.3]
17.33
[440.3]
0.61
[15.4]
0.61
[15.4]
18040-412 Guilford Rd. • Annapolis Junction, MD 20701
fiberplex.com • [email protected]
• 301.604.0100
UMCMP530