GeneralInstallationInstructions
Donotunpackthewaveguideassemblyuntilyouarereadytoinstallit.Thiswillpreventdamagetotheexternalthreadsonthebushing.
1. Preparetheshieldroomwallorthegroundplanebyboringmountingholes1‐5/32”(1.156”)diameterinthedesiredlocation.Any
adjacentholesshouldbenocloserthan2”.
2. Cleanandde‐burrtheareaaroundthemountingholestoinsuresuitableelectricalcontactandatightsealwiththewaveguide
mountingnuts.
3. Unpackthewaveguideassemblytakingcarenottodamagethethreadedbushing.
4. Loosenthe1/4”capscrewwhichretainsthepluginthebushing(approximately2turns).
5. Taptheendofthecapscrewuntiltheplugseparatesfromthebushing.
6. Removethecapscrewandthewasherandstoreinasafeplaceforfutureuse.
7. Removetheplugfromthebushing.Theplugisfastenedtooneofthemountingnutsbyashortcabletopreventdamagetoits
surfaceafterinstallationandalsotopreventinjuryduringsubsequentremoval.Itisnotnecessarytodisconnectthecablefrom
eitherthemountingnutortheplug.
8. Removethefreemountingnutfromthebushing.
9. Placethebushingthroughthemountingholessothatthecableisfacingawayfromthemountingsurface.
10. Replacethemountingnutontheoppositesideofthemountingsurface.Centerthebushingbyholdingthenutandrotatingthe
bushinguntilthereareequalthreadsonbothends.
11. Atthispointthewaveguideisinplacewiththeplughangingbyitscableononeside.Iftheinstallationappearstobeacceptable,
tightenthemountingnutoppositefromtheplugendwitha1‐1/2”socketwrenchtoamaximumtorqueof85foot‐poundsorthe
maximumtorquethatthewallcanwithstandwithoutcrushing.
12. Installthefiberopticcablesbyinsertingtheconnectorsoneatatimethroughthecenterboreofthebushing,andthenpushthe
cablesintothegroovesaroundtheedges.
13. Afterallofthefiberopticcableshavebeeninstalled(donotoverfillthewaveguidebores),inserttheplugintothecenterbore
takingcarenottodamagethecables.
14. Presstheplugfirmlytolockitintoplace.
15. Installthecapscrewandwasherintotheplugcarefullysoastonotpushtheplugouttheotherside.
16. Torquethecapscrewto6foot‐pounds.
17. Plugmayberemovedfortheadditionorremovaloffiberopticcablesandthenreinstalledasrequired.
DONOTHEATORWELDTHISFILTER.DAMAGEMAYRESULT.
Warranty,ServiceandTermsandConditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsofSale’.Thisdocumentisavailable
on
fiberplex.comorcanbeobtainedbyrequestingitfrom[email protected]orcalling301.604.0100.Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterialcanberecycled.Recycling
packingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedtodisposeofthetransportpackingmaterials,recyclingis
encouraged.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellassubstancesthatmustbedisposedofprofessionally.Pleasedisposeofused
equipmentviaanauthorizedspecialistdealerorviathepublicwastedisposalsystem,ensuringanymaterialthatcanberecycledhasbeen.
Pleasetakecarethatyourusedequipmentcannotbeabused.Afterhavingdisconnectedyourusedequipmentfromthemainssupply,make
surethatthemainsconnectorandthemainscablearemadeuseless.
Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeofpublication.However,noliabilityis
assumedbyFiberPlexforinaccuracies,errors,oromissions,norforlossordamageresultingeitherdirectlyorindirectlyfromuseofthe
informationcontainedherein.
USERMANUA
WaveguideWGF‐6