Fiberplex WGF-461 User manual

  • Hello! I've reviewed the user manual for the FiberPlex Waveguide WGF-461. This document provides detailed instructions for the installation process, including how to mount the device, connect the fiber optic cables, and handle the components safely. I am ready to answer your questions about the installation process, and other details described in the manual.
  • What size mounting holes are required?
    What is the maximum torque for the mounting nut?
    What is the torque for the cap screw?
USERMANUA
L
WaveguideWGF‐461
GeneralInstallationInstructions
Donotunpackthewaveguideassemblyuntilyouarereadytoinstallit.Thiswillpreventdamagetotheexternalthreadsonthebushing.
1. Preparetheshieldroomwallorthegroundplanebyboringmountingholes1‐5/32”(1.156”)diameterinthedesiredlocation.Any
adjacentholesshouldbenocloserthan2”.
2. Cleanandde‐burrtheareaaroundthemountingholestoinsuresuitableelectricalcontactandatightsealwiththewaveguide
mountingnuts.
3. Unpackthewaveguideassemblytakingcarenottodamagethethreadedbushing.
4. Loosenthe1/4”capscrewwhichretainsthepluginthebushing(approximately2turns).
5. Taptheendofthecapscrewuntiltheplugseparatesfromthebushing.
6. Removethecapscrewandthewasherandstoreinasafeplaceforfutureuse.
7. Removetheplugfromthebushing.Theplugisfastenedtooneofthemountingnutsbyashortcabletopreventdamagetoits
surfaceafterinstallationandalsotopreventinjuryduringsubsequentremoval.Itisnotnecessarytodisconnectthecablefrom
eitherthemountingnutortheplug.
8. Removethefreemountingnutfromthebushing.
9. Placethebushingthroughthemountingholessothatthecableisfacingawayfromthemountingsurface.
10. Replacethemountingnutontheoppositesideofthemountingsurface.Centerthebushingbyholdingthenutandrotatingthe
bushinguntilthereareequalthreadsonbothends.
11. Atthispointthewaveguideisinplacewiththeplughangingbyitscableononeside.Iftheinstallationappearstobeacceptable,
tightenthemountingnutoppositefromtheplugendwitha1‐1/2”socketwrenchtoamaximumtorqueof85foot‐poundsorthe
maximumtorquethatthewallcanwithstandwithoutcrushing.
12. Installthefiberopticcablesbyinsertingtheconnectorsoneatatimethroughthecenterboreofthebushing,andthenpushthe
cablesintothegroovesaroundtheedges.
13. Afterallofthefiberopticcableshavebeeninstalled(donotoverfillthewaveguidebores),inserttheplugintothecenterbore
takingcarenottodamagethecables.
14. Presstheplugfirmlytolockitintoplace.
15. Installthecapscrewandwasherintotheplugcarefullysoastonotpushtheplugouttheotherside.
16. Torquethecapscrewto6foot‐pounds.
17. Plugmayberemovedfortheadditionorremovaloffiberopticcablesandthenreinstalledasrequired.
DONOTHEATORWELDTHISFILTER.DAMAGEMAYRESULT.
Warranty,ServiceandTermsandConditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsofSale’.Thisdocumentisavailable
onfiberplex.comorcanbeobtainedbyrequestingitfrom[email protected]orcalling301.604.0100.
Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterialcanberecycled.Recycling
packingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedtodisposeofthetransportpackingmaterials,recyclingis
encouraged.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellassubstancesthatmustbedisposedofprofessionally.Pleasedisposeofused
equipmentviaanauthorizedspecialistdealerorviathepublicwastedisposalsystem,ensuringanymaterialthatcanberecycledhasbeen.
Pleasetakecarethatyourusedequipmentcannotbeabused.Afterhavingdisconnectedyourusedequipmentfromthemainssupply,make
surethatthemainsconnectorandthemainscablearemadeuseless.
Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeofpublication.However,noliabilityis
assumedbyFiberPlexforinaccuracies,errors,oromissions,norforlossordamageresultingeitherdirectlyorindirectlyfromuseofthe
informationcontainedherein.
Dimensions in inches
Tolerances:
Fraction +/- 1/64
x.xx +/- 0.01
x.xxx +/- 0.005
Unless otherwise specified
Material:
Finish:
C
SIZE:
Rev:
Scale: Sheet 1 of 1
-
2:1
WGF-461
2.27
.96 MAX
[24.3]
1-1/8 - 18
THD
R.079
[2.0]
1.50
THIS DRAWING CONTAINS PROPRIETARY AND CONFIDENTIAL INFORMATION OF FIBERPLEX TECHNOLOGIES, LLC
AND SHALL NOT BE USED, DISCLOSED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN
CONSENT OF FIBERPLEX TECHNOLOGIES. TITLE IN AND TO THIS DOCUMENT AND ALL INFORMATION
CONTAINED
HEREIN REMAINS AT ALL TIMES IN FIBERPLEX TECHNOLOGIES.
1.73
A
DETAIL A
SCALE 4 : 1
1.125 MIN HOLEn
[28.6]
1.75 RECOMMENDED CLRNCn
[44.4]
.60
0.184
0.157
[4.0]
TECHNOLOGIES LLC,
[38.1]
[57.3]
[44.0]
[4.67]
[15.24]

WGF461UM‐1611
18040-412 Guilford Rd. • Annapolis Junction, MD 20701
fiberplex.com • [email protected]