FOM‐9010Figure5DetectionModeDIPSwitches
Switch Parameter
SW1 DetectionModeSelectChannel1
TheseselectVoltageSenseModeorContactClosure/Open
CollectorModeforcorrespondingchannel.
DOWN(OFF)‐ChannelisinVoltageSenseMode.SeeS1/S2
settingsforfurthercontrolinthismode.
UP(ON)‐ChannelisinContactClosure/OpenCollectorMode.
SW2 DetectionModeSelectChannel2
SW3 DetectionModeSelectChannel3
SW4 DetectionModeSelectChannel4
SW5 DetectionModeSelectChannel5
SW6 DetectionModeSelectChannel6
SW7 DetectionModeSelectChannel7
SW8 DetectionModeSelectChannel8
SW9 DetectionModeSelectChannel9
SW10 DetectionModeSelectChannel10
SW11 DetectionModeSelectChannel11
SW12 DetectionModeSelectChannel12
FOM‐9010Figure6PolarityModeDIPSwitches
Switch Parameter
S1.1 PolaritySenseMode,Channel1
Theseselectwhethertheinputispolaritysensitiveornot.This
onlyappliesiftheDetectionModeswitchfortherespective
channelissetfor‘Voltage’.IftheDetectionModeswitchissetfor
‘dryContacts/OpenCollector’thenthisswitchhasnofunction.
DOWN(OFF)‐Voltagedetectionisnotpolaritysensitive.
UP(ON)‐Voltagedetectionispolaritysensitive.‘B’leadmustbe
positivewithrespectto‘A’leadfor‘on’.
S1.2 PolaritySenseMode,Channel2
S1.3 PolaritySenseMode,Channel3
S1.4 PolaritySenseMode,Channel4
S1.5 PolaritySenseMode,Channel5
S1.6 PolaritySenseMode,Channel6
S1.7 PolaritySenseMode,Channel7
S1.8 PolaritySenseMode,Channel8
S2.1 PolaritySenseMode,Channel9
S2.2 PolaritySenseMode,Channel10
S2.3 PolaritySenseMode,Channel11
S2.4 PolaritySenseMode,Channel12
S2.5
Reserved
S2.6
S2.7
S2.8
S3.1
Reserved
S3.2
S3.3
S3.4
S3.5 RemoteConfiguration DOWN(OFF)‐Allowremoteconfiguration
UP(ON)–Inhibitremoteconfiguration
S3.6 OpticalTXOnly EnablesordisablesthelocalRXopticsoperation.Powermustbe
cycledafterchangingthissetting.
DOWN(OFF)‐RXopticsareactiveinbidirectionalopticallink
allowingtheFOM‐9010todisplaythestatusoftheFOM‐9011or
FOM‐9012localRXopticalsignal.
UP(ON)‐UnitisTXonly.TheOPTICSledwillnotlight,asthereis
noexpectedsignalatthelocalRXopticalconnector.Ifthereisa
signalpresenttheOPTICSledwillflashred,indicatingthatthereis
asignalattachedtotheFOM‐9010whenonewasnotexpected.
Whenthelinkisinthismode,thereisnoreportingofthesignal
statusfromthefarend.
S3.7 Reserved
S3.8
LEDoperationMode
NormalLEDoperationsettingwillcausethefrontpaneldisplayto
flasheachoftheindicatorsanalternatingredandgreenfor
verificationpurposes.Theunitcontinuestofunctionnormally‐
onlythedisplayisaffected.
DOWN(OFF)‐Normalindicatoroperationselected.
UP(ON)‐Allindicatorsalternatelyflashredorgreen.