Fiberplex VIS-4832 User manual

Category
Musical Equipment
Type
User manual
USERMANUALFOR
VIS4832
1
WarningforYourProtection
1.Readtheseinstructions
2.Keeptheseinstructions
3.Heedallwarnings
4.Followallinstructions
5.Donotusethisapparatusnearwater.
6.Cleanonlywithadrycloth.
7.Donotblockanyoftheventilationopenings.Installinaccordancewiththemanufacturer’sinstructions.
8.Donotinstallnearanyheatsourcessuchasradiators,heatregisters,stoves,orotherapparatus(includingamplifiers)thatproduceheat.
9.Donotdefeatthesafetypurposeofthepolarizedorgroundingtypeplug.Apolarizedplughastwobladeswithonewiderthantheother.
Agroundingtypeplughastwobladesandathirdgroundingprong.Thewidebladeorthethirdprongareprovidedforyoursafety.Ifthe
providedplugdoesnotfitintoyouroutlet,consultanelectricianforreplacementoftheobsoleteoutlet.
10.Protectthepowercordfrombeingwalkedonorpinched,particularlyatplugs,conveniencereceptacles,andthepointwheretheyexit
fromtheapparatus.
11.Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
12.Useonlywiththecart,stand,tripod,bracket,ortablespecifiedbythemanufacturer,orsoldwiththeapparatus.
Whenacartisused,usecautionwhenmovingthecart/apparatuscombinationtoavoidinjuryfromtipover.
13.Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
14.Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushasbeendamaged
inanyway,suchaspowersupplycordorplugisdamaged,liquidhasbeenspilledorobjectshavefallenintothe
apparatus,theapparatushasbeenexposedtorainormoisture,doesnotoperatenormally,orhasbeendropped.
Theapparatusshallnotbeexposedtodrippingorsplashing.Noobjectsfilledwithliquids,suchasvases,shallbeplacedontheapparatus.
“WARNINGToreducetheriskoffireorelectricshock,donotexposethisapparatustorainormoisture.”
GeneralInstallationInstructions
Pleaseconsiderbesidesthesegeneralinstructionsalsoanyproductspecificinstructionsinthe“Installation”chapterofthismanual.
Unpacking
Checktheequipmentforanytransportdamage.Iftheunitismechanicallydamaged,ifliquidshavebeenspilledorifobjectshavefalleninto
theunit,itmustnotbeconnectedtotheACpoweroutlet,oritmustbeimmediatelydisconnectedbyunpluggingthepowercable.Repair
mustonlybeperformedbytrainedpersonnelinaccordancewiththeapplicableregulations.
InstallationSite
Installtheunitinaplacewherethefollowingconditionsaremet:
Thetemperatureandtherelativehumidityoftheenvironmentmustbewithinthespecifiedlimitsduring
operationoftheunit.Relevantvaluesaretheonesattheairinletsoftheunit.
Condensationmustbeavoided.Iftheunitisinstalledinalocationwithlargevariationofambienttemperature
(e.g.inanOBvan),appropriateprecautionsmustbetakenbeforeandafteroperation.
Unobstructedairflowisessentialforproperoperation.Airventsoftheunitareafunctionalpartofthedesign
andmustnotbeblockedinanywayduringoperation(e.g.byobjectsplaceduponthem,placementoftheuniton
asoftsurface,orinstallationoftheunitwithinarackorpieceoffurniture).
Theunitmustnotbeheatedupbyexternalsourcesofheatradiation(sunlight,spotlights).
2
AmbientTemperature
UnitsandsystemsbyLightViperaregenerallydesignedforanambienttemperaturerange(i.e.temperatureoftheincomingair)of+5...+40
°C.Whenrackmountingtheunits,thefollowingfactsmustbeconsidered:
Theadmissibleambienttemperaturerangeforoperationofthesemiconductorcomponentsis0°Cto+70°C
(commercialtemperaturerangeforoperation).
Theairflowthroughtheinstallationmustprovidethattheoutgoingairisalwayscoolerthan70°C.
Averageheatincreaseofthecoolingairshallbeabout20K,allowingforanadditionalmaximum10Kincreaseat
thehotcomponents.
Inordertodissipate1kWwiththisadmissibleaverageheatincrease,anairflowof2.65m³/minisrequired.
Example:ArackdissipatingP=800Wrequiresanairflowof0.8*2.65m³/minwhichcorrespondsto2.12
m³/min.
Ifthecoolingfunctionoftheinstallationmustbemonitored(e.g.forfanfailureorilluminationwithspotlamps),
theoutgoingairtemperaturemustbemeasureddirectlyabovethemodulesatseveralplaceswithin
EarthingandPowerSupply
Earthingofunitswithmainssupply(classIequipment)isperformedviatheprotectiveearth(PE)conductorintegratedinthemainscable.
Unitswithbatteryoperation(<60V,classIIIequipment)mustbeearthedseparately.Earthingtheunitisoneofthemeasuresforprotection
againstelectricalshockhazard(dangerousbodycurrents).Hazardousvoltagemaynotonlybecausedbydefectivepowersupplyinsulation,
butmayalsobeintroducedbytheconnectedaudioorcontrolcables.
Thisequipmentmayrequiretheuseofadifferentlinecord,attachmentplug,orboth,dependingontheavailablepowersourceat
installation.Iftheattachmentplugneedstobechanged,referservicingtoqualifiedservicepersonnel
IfyourunitmainssupplyisprovidedviaaNeutrikPowerCon™connectorthefollowingprecautionsmustbefollowed:
ThePowerConmustbeinstalledandfullyengagedbeforeACpowerisappliedtotheunit.
TheunitmustbedisconnectedfromthemainssupplybeforedisengagingthePowerConconnector.
ClassIEquipment(MainsOperation)
Shouldtheequipmentbedeliveredwithoutamatchingmainscable,thelatterhastobepreparedbyatrainedpersonusingtheattached
femaleplug(IEC320/C13orIEC320/C19)withrespecttotheapplicableregulationsinyourcountry.
BeforeconnectingtheequipmenttotheACpoweroutlet,checkthatthelocallinevoltagematchestheequipmentrating(voltage,
frequency)withintheadmissibletolerance.Theequipmentfusesmustberatedinaccordancewiththespecificationsontheequipment.
Equipmentsuppliedwitha3poleapplianceinlet(protectionconformingtoclassIequipment)mustbeconnectedtoa3poleACpower
outletsothattheequipmentcabinetisconnectedtotheprotectiveearth.
WARNING
Ifthegroundisdefeated,certainfaultconditionsintheunitorinthesystemtowhichitisconnectedcan
resultinfulllinevoltagebetweenchassisandearthground.Severeinjuryordeathcanthenresultifthe
chassisandearthgroundaretouchedsimultaneously.
3
Registration
BesuretoregisteryourLightViperproduct,eitherbyfillingintheenclosedRegistrationCardorbycompletingtheonlineregistrationform
atourWebsite:
http://lightviper.com/register.aspx
Ifyoudoso,FiberPlexcancontactyouwithanyupdateinformation.Asenhancementsandupgradesaredeveloped,youwillbecontactedat
theregistrationaddress.Pleasereadthismanual‐ifyoucallfortechnicalsupport,we’llassumethatyouhave.
PleaseaddressanyinquiriestoyourdealerordirectlytoFiberPlexat:
FiberPlexInc.
10840412GuilfordRd.
AnnapolisJunction,MD20701
301.604.0100Fax:301.604.0773
Warranty,ServiceandTermsandConditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsofSale’.Thisdocumentisavailable
onfiberplex.comorcanbeobtainedbyrequestingitfrom[email protected]orcalling301.604.0100.
4
Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterialcanberecycled.Recycling
packingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedtodisposeofthetransportpackingmaterials,pleasetrytouse
recyclablemeans.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellasmaterialsthatmustbedisposedofprofessionally.Pleasereturnyourused
equipmentviaanauthorizedspecialistdealerorviathepublicwastedisposalsystem,ensuringanymaterialthatcanberecycledis.Please
takecarethatyourusedequipmentcannotbeabused.Afterhavingdisconnectedyourusedequipmentfromthemainssupply,makesure
thatthemainsconnectorandthemainscablearemadeuseless.
DeclarationsofConformity
ClassAEquipment‐FCCNotice
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttoPart15oftheFCCRules.These
limitsaredesignedtoprovideareasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedinacommercial
environment.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe
instructionmanual,maycauseharmfulinterferencetoradiocommunications.Operationofthisequipmentinaresidentialareaislikelyto
causeharmfulinterference,inwhichcasetheuserwillberequiredtocorrecttheinterferenceattheirownexpense.

Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeofpublication.However,no
responsibilityistakenbyusforinaccuracies,errors,oromissions,norisanyliabilityassumedforanylossordamageresultingeitherdirectly
orindirectlyfromuseoftheinformationcontainedwithinit.
5
Introduction
CongratulationsonyourpurchaseofaLightViper4832fiberopticaudiosnakealightweight,flexiblebreakthroughforprofessionalsound
production.
LightViperproductsaredesigned,engineeredandmanufacturedbyFiberPlex,expertsinfiberopticswithdecadesofexperience.Ourwork
inaudioanddatacommunicationsproductsisknowninUSgovernmentapplicationsworldwide.LightViperproductscombineourfiber
optictechnologywiththehigheststandardsinaudioengineering.
TheVIS4832
YouhavepurchasedtheLightViper4832system,a32x8AESdigitalinputfiberoptictransportsystems(snake).Insteadoftraditionalheavy
multiconductorcoppercable,theLightVipersnakefeaturesalightweight,flexible,militarytacticalgradefiberopticcable.
TheFiberAdvantage
Fiberopticsoffermanyadvantagesovercopper:
Transmitslightratherthanelectrons
Transmissionovergreaterdistances(morethan2Km[1.25mile])
Completeelectricalisolation
ImmunitytoRFIandEMI
Eliminatesgroundloopproblems
Canberoutedoverhead,throughwalls,orunderground
Avoidsfoottrafficwhilemaintainingaesthetics
FunctionalConsiderations
TheLightViper4832isanactivedevice.Becauseofthis,therearesomeaspectsofthisnewtechnologythatrequiresomeslightlydifferent
thinking:
LightViper4832systemrequiresACPoweratboththeStage(VIS4832)andtheconsole(VIM1832)
The4832systemcontains(32)AESdigitalinputsonly.Therearenomicrophonepreamplifiersaswiththe1832
system
Allinputsexitthesnake(attheMixerBox)atLineLevel
InputandOutputflexibilitymayeliminatetheneedforsomeofyouroutboardgear
TheLightViperVIM4832isanactivedevice,thereforedonotattempttoconnectintercomintothereturns
ThereturnsintheVIS4832cannotbe“turnedaround”toprovide40sendsonewayaswithatraditionalcopper
snake,astheelectronicsforthereturnsarecontainedintheVIM1832.
6
StandardComponents
Initsstandardconfiguration,theLightViper4832systemiscomprisedofthefollowingprimarycomponents.
TheStageBox(VIS4832)Thisistheboxplacedclosetoalltheinputsonstage.Itisa1Urackmountdevice
thataccepts(32)AESdigitalinputs(sends)and(8)AESdigitalplus(8)analoglineleveloutputs(returns).
TheMixerBox(VIM1832)Thisunitcontains(32)simultaneousAESdigitalandanaloglineleveloutputs
(sends)and(8)AESdigitalor(8)analoglinelevelinputs(returns).Theunitshouldbemountedinarackcloseto
theprimary(FOH)mixingconsole
TheFiberCable(TFC000004)Thelightweight“tacticalgrade”fiber‘cable’thatcarriesthedigitalsignal
betweenthestageandmixerboxes.Forinstallationuse,eitherPVCorPlenumratedfiberisrecommended(VFC
0000D,VFC0000DP).
TAC4ConnectorPanels(VPL11,VPL12,VPL13)These1Urackpanelscontain(1),(2),or(3)panelmount
TAC4connectorsmountedrespectivelyandallowconnectionbetweentacticalgradefibertotheSTconnectors
ontheVIMunits.
Send/ReturnCables(VCBADXM,VCBADXF)ThesecablesconnecttheMixerBoxtotheanalog
inputs/outputsofyourmixer.IfyouareconnectingtoaYamahadigitalconsolethroughtheYamaha“Y”cards,
youwoulduseVCBDDMYandVCBDDMYIOcables.Avarietyofcablestoconnecttootherdigitalconsolesand
devicesarealsoavailable.
OptionalComponents
AdditionalcomponentscanbeaddedtotheLightViper4832forincreasedfunctionality.
VIMMY32CardsTheVIMMY32canreplacetheVIM1832primaryconnectionoraVIM1032onasplit
connection.TheVIMMY32cardsetisdesignedtobeinstalleddirectlyintoaYamahaconsolecapableof
acceptingYGDAIcards.
AdditionalSendBox(es)(VIM1032)TheVIM1032issimilartotheVIM1832mixerboxinthatitprovidesa
parallelsetofthesnake’s32inputchannels,viaanadditionalFiberCable,inapplicationswhereyouneedsplits
forrecording,broadcast,ormonitormixing.TheVIS4832StageBoxcanbefitwithtwo“split”connectorsfora
totalofthree(1VIM1832(Primary)+2VIM1032(splits)outputs.
AdditionalAnalogFanOutCable(s)(VCBADXM/VCBADXF)Thesefanoutcablesarenecessaryforconnecting
additionalmixerboxes(VIM1832andVIM1032)toyouranalogequipment.Youneed(4)VCBADXMforeach
VIM1832orVIM1032mixerboxesinthesystem.TheVIM1832alsorequires(1)VCBADXF(female)fanoutto
accessthereturns.
AdditionalDigitalCablesToconnectAESdigitaldirectlyintoaYamahaPM5D,DM2000,DM1000orM7,you
need(2)optionalcablesforeach32x8system.(1)DDMYand(1)DDMYIOwillallowa32x8connectionintothe
YamahaMY16AEcards.OptionalcablesareavailabletointerfacewithProToolsandothertypesofdevicesand
variousconnectorconfigurations.
EthernetControlAddtheoptionalETH1832(pair)optiontoanyStage/FOHpath,andcontrolavarietyof
EthernetbasedgearonstagefromtheFOHposition.
AdditionalFiberCable(s)Forliveproduction,TFC000004tacticalgradefiberwithTAC4Connector
terminationsisrequiredbetweenthestagebox(VIS1832)andallmixerboxes.Forinstallationswherethefiber
willbepulledthroughconduit,eitherVFC0000D(PVCfiber)orVFC0000DP(Plenumratedfiber)withST
connectorterminationsisrecommended.Thereisalsoanoptionfora“PullingEye”whichcanbespecifiedby
addingan“PE”tothepartnumbersabove.Thisoptionincludesastrainreliefandpullingeyeononeendofthe
fiberopticcable.
TAC4andOpticalConconnectorscanalsobefitdirectlyonthechassisoftheVIS4832,VIM1832andVIM1032,
inapplicationssuchasthese,rackearsandVPLpanelsarenotrequired.
*Pleaserefertopage12foracompletelistandphotosoffiberopticcabletypesaswellascopperinterfacecables.
7
GettingStarted
SettingupandusingyourLightViper4832isaquickandsimpleprocess.Justfollowthesesteps:
1. PlacetheVIS4832inarackwithyourdigitalmicpre’sorothersource.PlacetheVIM1832MixerBoxclosetothemixersothat
thesendcablescanreachtheconsole’sinputs.connectACpower.
2. ConnectandruntheFiberbetweenthetwoboxes,powerupandchecktheSynclightonbothunits
3. Connecttheinputsandreturnstothestagebox.
4. Connecttheanalogfanoutordigitalcablestotheconsoleorrecordingdevice.
5. IfremotecontrollingYamahaAD8HRorAphexmicpre’sviaaYamahaconsole,attheconsoleendconnecttheDGL422fromthe
Yamaha9pincontrolconnectortotheVIM1832RJ45“control”connector.Atthestageend,connecttheDGL422cablefromthe
RJ45“control”connectorontheVIS4832tothe9pinremotecontrolconnectorontheAD8HRmicpre’s.
6. Startmixing.
NOTE:thesignaloutputoftheVIS4832ontheanalogoutputsislinelevel.Whenconnectingthissysteminto
aconsoleorotherdevice,uselinelevelinputsorengageinputpadstoachieveoptimalsignaltonoiseratio.
ThemoreadvancedfunctionsoftheLightViperVIS4832(control,clocks,etc.)areaddressedlaterinthis
manual.
8
TheStageBoxVIS4832
AnalogReturns(outputs)The(8)returnsareconnectedvia
asingleDB25connector.Returnsarelinelevel.
DigitalReturns(outputs)The(8)digitalreturnsare
connectedviaasingleDB25connector.ReturnsareallAES
digital.
Sends(inputs)The(32)AESdigitalinputsontheVIS4832
areconnectedvia(2)DB25connectors,(16)channelsperDB25
connector.
FiberConnectionsTheVIS4832hasaprimaryfiber
connectorstandard.Thefiberconnectormarked“primary”needs
tobeconnectedtoaVIM1832atalltimesastheVIM1832
providesthesystemclock.Therearealso(2)additional(optional)
fiberoutputsfromtheVIS4832thatwouldconnectviafiberto
VIM1032mixerboxes.Alwaysbecertaintouseappropriatefiber
andconnectors.LightVipersystemsusemultimodefiber.Single
modeopticsareavailableonacustombasisforsituationswhere
singlemodefibermayalreadyexist.
ControlCircuitsConnectorThisRJ45connectorprovides
(3)bidirectionalCMOSorTTLdatalines(upto38.4KHzfrom
StagetoFOHand2MHzfromFOHtostage)plusvoltageand
GND.ThisconnectorisusedinconjunctionwithDGL422cables
fortransportingYamahacontrol,orwithMD3unitstotransport
RS422,RS232orMIDI.THISISNOTANETHERNETCONNECTOR
CONNECTINGANETHERNETDEVICETOTHISCONNECTOR
COULDDAMAGETHEDEVICE.Thepinoutsforthisconnectorare
detailedintheappendix.MostCMOSorTTLfunctions/
equipmentcanbeadaptedtomakeuseofthisconnector.
SyncLEDThisLEDindicatesthestatusofthefiberoptic
linkbetweenthestagebox(VIS4832)andmixerbox(VIM1832).
Ithasthreestates;SOLIDREDindicatesthereisnosyncpresent;
ALTERNATINGRED&GREENindicatestheunitissearchingfor
sync;SOLIDGREENindicatessyncispresent(opticallink)andOFF
indicatesnopower.
PowerConnector/FuseTheACpowerconnectiontothe
VIS4832ismadeviaasuppliedIECpowercord.Theinternal
powersupplycanaccept90260Vateither50or60Hz>The
powerfuseisa5x20mm,1ASloBlo.Onlyreplacethefusewith
anexactmatch.Ifafterreplacementthefuseblowsagain,
contactFiberplexforservice.
WordClock/SuperClockoutput
Optional(ETH1832)Ethernetconnector
9
8
7
6
5
4
3
2
1
1 2
3
4
5 6
7
8 9
9
TheMixerBoxVIM1832
AnalogSends(outputs)‐ExitingtheMixerBox,thesendsfrom
theStageBoxaregroupedin4groupsof8.Eachgroupisaccessed
viaDB25toXLR“fanout”cables.DB25TO1/4”cablesarealso
availableforusewithmixersthatonlyallowlinelevelconnection
through1/4”jacks.EachsendexitstheMixerBoxatLineLevel,
maximizingheadroomontheconsole.
AnalogReturns(inputs)‐TheanalogreturnstotheStagebox
aremadeviaasingleDB25toXLR“fanout”cable.TheDB25
connectorsonboththeAnalogSendsandReturnsutilizestandard
DA88,TASCAMbalancedpinoutconfiguration.Connectorpinouts
areillustratedintheAppendix.
ReturnSelectSwitch‐The8returnchannelsareswitch
selectableasEITHERanalogORdigital.Thisselectionismadeviathe
recessedswitchinthecenteroftheMixerBoxadjacenttotheclock
connections.
DigitalReturns(inputs)‐ThedigitalreturnstotheStagebox
aremadeviaasingleDB25toXLRFcable.TheseinputsMUSTbe
usedinconjunctionwiththeClockI/Odescribedbelowineither
masterorslavemode.TheDB25connectorsonboththeDigital
SendsandReturnsutilizeastandardAES3balancedpinout
configuration.Cableandconnectorpinoutsareillustratedinthe
Appendix.NOTE:TheAnalogDA88cablesarenotpincompatible
withthedigitalcables.
DigitalSends(outputs)‐Thesendsfromthestageboxare
simultaneouslyavailableasAES3digitalsignals.Connectionsare
madevia2DB25connectors,with16channelsoneach.Accessto
thedigitalsignalallowsforconnectiontodigitalrecordersor
consoles,bypassingtheironboardconvertersandeliminatingthe
needforoutboardconverters.Fordigitalconnectionstraightintoa
YamahaPM5D,DM2000,DM1000orM7CL,theoptionalVCBDDMY
andVCBDDMYIOcablesconnectdirectlytotheYamahaMY16AE
cards.CablesareavailabletoconnecttoProTools,orotherdevices.
ClockI/O‐Byitself,theentireLightVipersystemisinternally
frequencycoherent.TheVIM1832MixerBoxcontainstheclock
masterforthesystem,andtheStageBoxandanyothersendunits
thatareconnectedviatheopticalsplitsallsynctotheclock
providedbythemaster.TheLightViper1832systemrunsnativelyat
24bit/96k,butcanalsorunat24bit/48kwitha48kclockinputto
the“clockin”connectorontheVIM1832.
TheclockI/Oisusedwhenyouneedtosynchronizewithexternal
equipmentmakingtheentiresystemfrequencycoherent.When
usingthedigitalreturnstheVIMMUSTBEineithermasterorslave
modewiththeequipmentprovidingthedigitalinput.
TheClockinputwillaccepteither“WordClock”(96KHz/48kHz)or
“SuperClock”(24.576MHz/12.288MHz).Outputsareprovidedfor
bothclocktypes.
ThesystemcanoperateinSlaveMode—Inthismodeclockis
suppliedviathe“clockin”connectoroverridingtheinternalclock.
The“clockoutputs”arepassthroughsfortheclockconnectedto
theinput.
InMasterModethereisnothingconnectedtotheinputand
externalequipmentisconnectedtotheClockOut,makingthe
internalclockthemasterinthesystem.
TheLEDnexttotheClockInconnectorhasthreestatestoindicate
Status.
Off—NosignalpresentontheClockInput
Red—SignalispresentontheClockInputbutitisneitheravalid
WordClocknorSuperClock
Green—ThereiseitheravalidWordClockorSuperClocksignalon
theClockIn
FiberConnector‐TheMixerBoxcanbefitwithSTconnectors,
asingletacticalgradeTAC4connector,oraNeutrikOpticalCon
connector.Inliveproductionuse,itisrecommendedtofittheVIM
1832andVIM1032unitswithSTconnectors,andutilizetheVPL11,
12or13panelscontaining1,2,and3,TAC4panelmount
connectorsrespectively.TheseconnectorshaveSTpigtailswhich
connectwiththemixerboxSTconnectors.Alwaysbesuretouse
appropriatefiberandcompatibleconnectors.
ControlCircuitsConnector‐ThisRJ45jackprovides(3)bi
direction(mixerboxtostagebox)CMOSorTTLdatalines(upto
38.4KHzfromStagetoFOHand2MHzfromFOHtoStage)plus
voltageandGND.THISISNOTANETHERNETCONNECTOR
CONNECTINGANETHERNETDEVICETOTHISCONNECTORCOULD
DAMAGETHEDEVICE.ThePinOutsforthisconnectoraredetailed
intheAppendix.MostCMOSorTTLfunctions/equipmentcanbe
adaptedtomakeuseofthisconnector.
SyncLEDThisLEDindicatesthestatusofthefiberopticlink
betweentheVIM1808andVIM0808.Ithasthreestates;SOLID
REDindicatesthereisnosyncpresent;ALTERNATINGRED&GREEN
indicatestheunitissearchingforsync;SOLIDGREENindicatessync
ispresent(opticallink)andOFFindicatesnopower.
PowerConnector/Fuse‐PowertotheMixerBoxisprovided
withthesupplied3ProngIECPowerCord.Theinternalpower
supplycanacceptanyvoltagefrom90260ateither50or60Hz.The
powerfuseisa5x20mm,1ASloBlo.Onlyreplacethefusewithan
exactmatch.Ifafterreplacementthefuseblowsagain,returnthe
unitforservice.
10
9
8
7
6
5
4
3
2
1
1 2
3
4
5
6
7 8 9
10
10
FunctionalBlockDiagramwithOneOpticalSplit
VIS-4832
TTL CTL
PTx
PRx
S1Tx
S2Tx
AOut 1
AOut 2
AOut 3
AOut 4
AOut 5
AOut 6
AOut 7
AOut 8
DOut 1/2
DOut 3/4
DOut 5/6
DOut 7/8
DIn 1/2
DIn 3/4
DIn 5/6
DIn 7/8
DIn 9/10
DIn 11/12
DIn 13/14
DIn 15/16
DIn 17/18
DIn 19/20
DIn 21/22
DIn 23/24
DIn 25/26
DIn 27/28
DIn 29/30
DIn 31/32
WCLK Out
VIM-1832
TTL CTL
PTx
PRx
AOut 1
AOut 2
AOut 3
AOut 4
AOut 5
AOut 6
AOut 7
AOut 8
AOut 9
AOut 10
AOut 11
AOut 12
AOut 13
AOut 14
AOut 15
AOut 16
AOut 17
AOut 18
AOut 19
AOut 20
AOut 21
AOut 22
AOut 23
AOut 24
AOut 25
AOut 26
AOut 27
AOut 28
AOut 29
AOut 30
AOut 31
AOut 32
AIn 1
AIn 2
AIn 3
AIn 4
AIn 5
AIn 6
AIn 7
AIn 8
DIn 1/2
DIn 3/4
DIn 5/6
DIn 7/8
DOut 1/2
DOut 3/4
DOut 5/6
DOut 7/8
DOut 9/10
DOut 11/12
DOut 13/14
DOut 15/16
DOut 17/18
DOut 19/20
DOut 21/22
DOut 23/24
DOut 25/26
DOut 27/28
DOut 29/30
DOut 31/32
WCLK In
WCLK Out
VIM-1032
PRx
AOut 1
AOut 2
AOut 3
AOut 4
AOut 5
AOut 6
AOut 7
AOut 8
AOut 9
AOut 10
AOut 11
AOut 12
AOut 13
AOut 14
AOut 15
AOut 16
AOut 17
AOut 18
AOut 19
AOut 20
AOut 21
AOut 22
AOut 23
AOut 24
AOut 25
AOut 26
AOut 27
AOut 28
AOut 29
AOut 30
AOut 31
AOut 32
DOut 1/2
DOut 3/4
DOut 5/6
DOut 7/8
DOut 9/10
DOut 11/12
DOut 13/14
DOut 15/16
DOut 17/18
DOut 19/20
DOut 21/22
DOut 23/24
DOut 25/26
DOut 27/28
DOut 29/30
DOut 31/32
WCLK Out
11
StandardYamahaConfiguration
W
CLK
OUT
S
CLK
OUT
Return s R1-R8
ANALOG
Returns R1-R8 Sends S1-S16
Sends S17-S32
DIGITAL AES3
Ethernet
Control
SYNC
PrimarySplit Split 90-260 VAC 50-60 Hz
5x20mm 1 Amp Slo-Blo
VIS-4832 (Stage)
96kHz
88.2kHz
48kHz
44.1kHz
WORD CL OCK IN
DIGITAL OUT A
+48V
HPF
dB
POWER
+48V
MASTER
OFF ON
10
1EVEN
-6
-12
-48
-30
-18
+48V
HPF
2EVEN
-6
-12
-48
-30
-18
+48V
HPF
3EVEN
-6
-12
-48
-30
-18
+48V
HPF
4EVEN
-6
-12
-48
-30
-18
+48V
HPF
5EVEN
-6
-12
-48
-30
-18
+48V
HPF
6EVEN
-6
-12
-48
-30
-18
+48V
HPF
8EVEN
-6
-12
-48
-30
-18
+48V
HPF
7EVEN
-6
-12
-48
-30
-18
+48V
HPF
96kHz
88.2kHz
48kHz
44.1kHz
WORD CL OCK IN
DIGITAL OUT A
+48V
HPF
dB
POWER
+48V
MASTER
OFF ON
10
1EVEN
-6
-12
-48
-30
-18
+48V
HPF
2EVEN
-6
-12
-48
-30
-18
+48V
HPF
3EVEN
-6
-12
-48
-30
-18
+48V
HPF
4EVEN
-6
-12
-48
-30
-18
+48V
HPF
5EVEN
-6
-12
-48
-30
-18
+48V
HPF
6EVEN
-6
-12
-48
-30
-18
+48V
HPF
8EVEN
-6
-12
-48
-30
-18
+48V
HPF
7EVEN
-6
-12
-48
-30
-18
+48V
HPF
96kHz
88.2kHz
48kHz
44.1kHz
WORD CL OCK IN
DIGITAL OUT A
+48V
HPF
dB
POWER
+48V
MASTER
OFF ON
10
1EVEN
-6
-12
-48
-30
-18
+48V
HPF
2EVEN
-6
-12
-48
-30
-18
+48V
HPF
3EVEN
-6
-12
-48
-30
-18
+48V
HPF
4EVEN
-6
-12
-48
-30
-18
+48V
HPF
5EVEN
-6
-12
-48
-30
-18
+48V
HPF
6EVEN
-6
-12
-48
-30
-18
+48V
HPF
8EVEN
-6
-12
-48
-30
-18
+48V
HPF
7EVEN
-6
-12
-48
-30
-18
+48V
HPF
96kHz
88.2kHz
48kHz
44.1kHz
WORD CL OCK IN
DIGITAL OUT A
+48V
HPF
dB
POWER
+48V
MASTER
OFF ON
10
1EVEN
-6
-12
-48
-30
-18
+48V
HPF
2EVEN
-6
-12
-48
-30
-18
+48V
HPF
3EVEN
-6
-12
-48
-30
-18
+48V
HPF
4EVEN
-6
-12
-48
-30
-18
+48V
HPF
5EVEN
-6
-12
-48
-30
-18
+48V
HPF
6EVEN
-6
-12
-48
-30
-18
+48V
HPF
8EVEN
-6
-12
-48
-30
-18
+48V
HPF
7EVEN
-6
-12
-48
-30
-18
+48V
HPF
AES Ch 1-8 (Audio 1-16)
VCB-DDAD8HR
AES Ch 9-16 (Audio 17-32)
VCB-DDAD8HR
48K Word
Clock
To Analog
Amps
To Digital
Amps
AD8HR (x4)
VIM-1032 (Split)
W
CLK
OUT
S
CLK
OUT
SYNC
90-260 VAC 50-60 Hz
5x20mm 1 Amp Slo-Blo
Sends S1-S16
Sends S17-S32
DIGITAL AES3
Sends S1-S8
Sends S9-S16
Sends S17-S24
Sends S25-S32
ANALOG
RS-422 Control
DGL-422
PM5D / M7CL / DM2000 / LS9 / etc
VIM-MY32
Fiber Cable
Primary Fiber Cable
12
FiberOptions
Tacticalgrademilitaryfiber‐(TAC4)isusedforliveproductionapplications(P/NTFC000004).Weighing8.4
lbs.(12.6kg)for(300)feet,thiscablecontains(4)fibersandthereforeitiscapableofcarryingthesignalsof(2)
systemsonasinglecable.TheTAC4connectorsarehermaphroditicandcanbeconnectedtooneanother.
Multimodefibercantransportsignalsupto2km(1.25miles).
NeutrikOpticalCon®Fiberthisfibercablecontains(2)fibersandisalsoatacticalgradefiber
(P/NTFC000002OC).
PVCfiberPVCduplexfibercontains(2)fibers.Plenumratedfiberisalsoavailable.Theinstallercan
terminatethefiberthemselves,orFiberplexcansupplyitpreterminated.Thisfiberisalsoavailablewitha
strainreliefand“pullingeye”whichreducesonsitelabor.

Neutrik OpticalCon
Fiber Cable & Panel
Mount Connecto
r
Plenum Install Fiber
TAC-4
13
LightViperVIS4832Specification
32 x 8 digital input fiber optic transport
Cable runs over 1.25 miles with no loss
Rugged fiber cable smaller in diameter than standard mic
cable
24 bit / 96kHz sampling (native), 24 bit / 48kHz (external)
Heavy gauge steel construction
Optional lossless 3 way split of all 32 channels on
stage end
Simultaneous analog / AES3 digital outputs on all 32
Channels
Extended range and flexibility means limitless
routing options
1. General Specifications
Total Harmonic Distortion
*1
Less than 0.01% 1 KHz @ +4 dBu
Frequency Response ± 0.5 dB 20-20kHz @ +16 dBu
Dynamic Range 102 dB
Crosstalk 5 dB above noise floor
Sampling Rate 24 bit / 96kHz or 24 bit / 48 kHz
Latency 20 s one way, digital input to digital output
Operating Temp 0 to +50°C ambient temperature.
Sync LED LED (green) indicates optical link OK, LED (red) indicates problem with optical link, LED (off) indicates no power.
AC Power Universal 90-250 VAC, 50/60 Hz, IEC connector with fuse (VIS-4832, VIM-1832 & VIM-1032)
Max Current Rating VIS-4832 / VIM-1832 / VIM-1032 0.473 mA @ 90V
On / Off Control Date + RJ-45 connector for logic level control, CMOS or TTL at 2 MHz max per channel.
Dimensions VIM-4832 / VIM-1832 / VIM-1032 1 Rack Unit X 6.5" Deep
Weight VIM-4832 / VIM-1832 / VIM-1032
300 ft Fiber Cable
6.5 lbs
6 lbs
*1-Hum & Noise are measured with an AES17 compliant filter at 20 kHz. Temperature condition @+10 - +25° C.
2.1 Input Characteristics
Connection Gain Setting Voltage Gain*2 Sensitivity*3
S/N ref +0dBu
Overload
Clipping
Input Impedance
Digital Sends
1-32*4
(VIS-4832) AES Digital
Analog
Returns 1-8
(VIS-4832) n/a 0(0 dB)
1.65 mVrms -83 dBu +16 dBu +19 dBu 2 K
Digital Returns
1-8
(Mixer End)
AES3 Digital
*1–Hum & Noise are measured with an AES17 compliant filter at 20 kHz. Temperature condition @+10 - +25° C. *2–0dBu is referenced to 0.775Vrms. *3–Sensitivity is the lowest level that will
produce an output of +4dBu (1.23V).
2.2 Output Characteristics
Connection Actual Source
Impedance For Use With Nominal Output Level
Nominal Connector
Analog Returns 1-8 (Stage
*1
150  600
Lines +4 dBu (1.23 +19 dBu (7 V) DB-25, 8 channels per connector
Digital Returns 1-8 AES Digital DB-25, 8 channels per vonnector
Digital Sends 1-32 (Mixer AES3 Digital DB-25, 16 channels per connector
2.3 Optical Characteristics
Connector*1 Installation Tension Operating Tension Min Bend Radius Crush Resistance Weight
Fiber-Optic Cable*2 400 lbs 130 lbs 3.7" 228 lb/in2 19 lbs / 1000'
Optical Fiber*3 Attenuation Bandwidth Numerical Aperture System Optical Data Rate System Operating Distance
1 dB/Km @1300 nm 500 MHz/Km @ 1300 0.275 122 Mbs 2 Km (1.25 mi)
*1–TAC-4 4 channel SMPTE compliant, *2–Four Channel Tactical Break Out Cable, 0.30"(7.5mm) Outer Diameter, Kevlar™ Strength Member *3–Graded Index, Multimode, Dual Window
(850/1300nm)
14
ANALOG – DB25 Cable Pin Outs
1. Ch. 8 +
2. Ch. 8 G
3. Ch. 7 -
4. Ch. 6 +
5. Ch. 6 G
6. Ch. 5 -
7. Ch. 4 +
8. Ch. 4 G
9. Ch. 3 -
10. Ch. 2 +
11. Ch. 2 G
12. Ch. 1 -
13. Unused
14. Ch. 8 -
15. Ch. 7 +
16. Ch. 7 G
17. Ch. 6 -
18. Ch. 5 +
19. Ch. 5 G
20. Ch. 4 -
21. Ch. 3 +
22. Ch. 3 G
23. Ch. 2 -
24. Ch. 1 +
25. Ch. 1 G
ANALOG Connector Pin Outs
1. Ch. 8 +
2. Ch. 8 G
3. Ch. 7 -
4. Ch. 6 +
5. Ch. 6 G
6. Ch. 5 -
7. Ch. 4 +
8. Ch. 4 G
9. Ch. 3 -
10. Ch. 2 +
11. Ch. 2 G
12. Ch. 1 -
13. Unused
14. Ch. 8 -
15. Ch. 7 +
16. Ch. 7 G
17. Ch. 6 -
18. Ch. 5 +
19. Ch. 5 G
20. Ch. 4 -
21. Ch. 3 +
22. Ch. 3 G
23. Ch. 2 -
24. Ch. 1 +
25. Ch. 1 G
Digital Connector Pin Outs
1. Ch 1&2 +
2. Ch. 3&4 +
3. Ch 5&6 +
4. Ch. 7&8 +
5. Ch. 9&10 +
6. Ch. 11&12 +
7. Ch. 13&14 +
8. Ch 15 & 16 +
9. Unused
10. Gnd.
11. Unused
12. Gnd.
13. Gnd.
14. Ch 1&2 -
15. Ch. 3&4 -
16. Ch. 5&6 -
17. Ch. 7&8 -
18. Ch. 9&10 -
19. Ch. 11&12 -
20. Ch. 13&14 -
21. Ch. 15&16 -
22. Gnd.
23. Unused
24. Gnd.
25. Gnd.
Digital Connector Pin Outs
1. Ch 1&2 +
2. Ch. 3&4 +
3. Ch 5&6 +
4. Ch. 7&8 +
5. Ch. 9&10 +
6. Ch. 11&12 +
7. Ch. 13&14 +
8. Ch 15 & 16 +
9. Unused
10. Gnd.
11. Unused
12. Gnd.
13. Gnd.
14. Ch 1&2 -
15. Ch. 3&4 -
16. Ch. 5&6 -
17. Ch. 7&8 -
18. Ch. 9&10 -
19. Ch. 11&12 -
20. Ch. 13&14 -
21. Ch. 15&16 -
22. Gnd.
23. Unused
24. Gnd.
25. Gnd.
Control Circuits RJ-45 Pin Outs
1. GND
2. TX1
3. TX2
4. TX3
5. RX1
6. RX2
7. RX3
8. VCC +5VDC
15
FiberConnectionPlates
EachfiberconnectiononLightVipercomponentscanbeconfiguredwith
anyoftheplatesinthediagram.Theplatesaccommodatedifferentfiber
connectortypeseithersingly.FourdifferentSTplatesaccommodate1,2,
3,or4STconnections.Ablankplateshouldalwaysbeinstalledinan
unusedconnectionbay.
TAC4InstallationInstructions
WhenusingTAC4panelmountconnectors:
DuetothehermaphroditicnatureoftheTAC4connector,channels1&4and
2&3arecrossedbynecessity.Therefore,pins1&2shouldalwaysbe
connectedtoconnectorsmarkedTXandpins3&4shouldalwaysbe
connectedtopinsmarkedRX.Pins1&4arealwayspairedtogetherandpins2
&3willalwaysbepairedtogether.
ImportantNote:AsingleTAC4connectorandcablecontains(4)fibersand
cantransportbothpairsoffiberinputs/outputsoftheEF2onasingle
connector/cable.IfusingNeutrikOpticalCon,twocables/connectorsare
required,oneforeachpair,astheOpticalConcableandconnectorscontain
(2)fibers.WhenusingSTfiberconnectorsonthechassisoftheEF2,theST
connectorsmaybemountedontherearoftheunit,oralternativelyonthe
frontpaneloftheunit.
17

Thispageintentionallyleftblank
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Fiberplex VIS-4832 User manual

Category
Musical Equipment
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI