Fiberplex RMC-3101, RMC-2101 User manual

  • Hello! I have read the user manual for the Fiberplex RMC-2101, RMC-3101, and RMC-3102 rack mount chassis. This document provides information on installation, power requirements, and module insertion. I understand it covers chassis features, specifications, and fuse replacement procedures. I am ready to answer your questions about these chassis and their functionality.
  • How many slots are available for fiber optic isolators?
    What power supply module is included with the chassis?
    Where is the cable bay located?
    Can the power supplies be replaced while in operation?

USERMANUAL
RackMountChassis
RMC2101/RMC3101/RMC3102
WarningforYourProtection
1.Readtheseinstructions.
2.Keeptheseinstructions.
3.Heedallwarnings.
4.Followallinstructions.
5.Donotusethisapparatusnearwater.
6.Cleanonlywithadrycloth.
7.Donotblockanyoftheventilationopenings.Installinaccordancewiththemanufacturer’sinstructions.
8.Donotinstallnearanyheatsourcessuchasradiators,heatregisters,stoves,orotherapparatus(includingamplifiers)thatproduceheat.
9.Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
10.Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
11.Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushasbeendamagedinanyway,suchaspowersupply
cordorplugisdamaged,liquidhasbeenspilledorobjectshavefallenintotheapparatus,theapparatushasbeenexposedtorainormoisture,does
notoperatenormally,orhasbeendropped.
Theapparatusshallnotbeexposedtodrippingorsplashing.Noobjectsfilledwithliquids,suchasvases,shallbeplacedontheapparatus.
“WARNING:Toreducetheriskoffireorelectricshock,donotexposethisapparatustorainormoisture.”
GeneralInstallationInstructions
Pleaseconsiderthesegeneralinstructionsinadditiontoanyproductspecificinstructionsinthe“Installation”chapterofthismanual.
Unpacking
Checktheequipmentforanytransportdamage.Iftheunitismechanicallydamaged,ifliquidshavebeenspilledorifobjectshavefallenintothe
unit,itmustnotbeconnectedtotheACpoweroutlet,oritmustbeimmediatelydisconnectedbyunpluggingthepowercable.Repairmustonlybe
performedbytrainedpersonnelinaccordancewiththeapplicableregulations.
InstallationSite
Installtheunitinaplacewherethefollowingconditionsaremet:
Thetemperatureandtherelativehumidityoftheoperatingenvironmentmustbewithinthespecifiedlimitsduringoperationofthe
unit.Valuesspecifiedareapplicabletotheairinletsoftheunit.
Condensationmaynotbepresentduringoperation.Iftheunitisinstalledinalocationsubjecttolargevariationsofambient
temperature(e.g.inanOBvan),appropriateprecautionsmustbetaken.
Unobstructedairflowisessentialforproperoperation.Ventilationopeningsoftheunitareafunctionalpartofthedesignandmust
notbeobstructedinanywayduringoperation(e.g.‐byobjectsplaceduponthem,placementoftheunitonasoftsurface,or
improperinstallationoftheunitwithinarackorpieceoffurniture).
Theunitmustnotbeundulyexposedtoexternalheatsources(directsunlight,spotlights).
AmbientTemperature
UnitsandsystemsbyFiberPlexaregenerallydesignedforanambienttemperaturerange(i.e.temperatureoftheincomingair)of+5...+40°C.
Whenrackmountingtheunits,thefollowingfactsmustbeconsidered:
Thepermissibleambienttemperaturerangeforoperationofthesemiconductorcomponentsis0°Cto+70°C(commercial
temperaturerangeforoperation).
Theairflowthroughtheinstallationmustallowexhaustairtoremaincoolerthan70°Catalltimes.
Averagetemperatureincreaseofthecoolingairshallbeabout20C°,allowingforanadditionalmaximum10increaseatthe
hottestcomponents.
Ifthecoolingfunctionoftheinstallationmustbemonitored(e.g.forfanfailureorilluminationwithspotlamps),theexhaustairtemperaturemust
bemeasureddirectlyabovethemodulesatseveralplaceswithintheenclosure.
GroundingandPowerSupply
Groundingofunitswithmainssupply(classIequipment)isperformedviatheprotectiveearth(PE)conductorintegratedinthemainscable.Units
withbatteryoperation(<60V,classIIIequipment)mustbeearthedseparately.Groundingtheunitisoneofthemeasuresforprotectionagainst
electricalshockhazard(dangerousbodycurrents).Hazardousvoltagemaynotonlybecausedbydefectivepowersupplyinsulation,butmayalso
beintroducedbytheconnectedaudioorcontrolcables.
Thisequipmentmayrequiretheuseofadifferentlinecord,attachmentplug,orboth,dependingontheavailablepowersourceatinstallation.If
theattachmentplugneedstobechanged,referservicingtoqualifiedpersonnel.
ClassIEquipment(MainsOperation)
Shouldtheequipmentbedeliveredwithoutamatchingmainscable,thelatterhastobepreparedbyatrainedpersonusingtheattachedfemale
plug(IEC320/C13orIEC320/C19)withrespecttotheapplicableregulationsinyourcountry.
BeforeconnectingtheequipmenttotheACpoweroutlet,checkthatthelocallinevoltagematchestheequipmentrating(voltage,frequency)
withintheadmissibletolerance.Theequipmentfusesmustberatedinaccordancewiththespecificationsontheequipment.
Equipmentsuppliedwitha3poleapplianceinlet(protectionconformingtoclassIequipment)mustbeconnectedtoa3poleACpoweroutletso
thattheequipmentcabinetisconnectedtotheprotectiveearth.
WARNING:
Ifthegroundisdefeated,certainfaultconditionsintheunitorinthesystemtowhichitisconnected
canresultinfulllinevoltagebetweenchassisandearthground.Severeinjuryordeathcanthenresult
ifthechassisandearthgroundaretouchedsimultaneously.
Warranty,ServiceandTermsandConditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsof
Sale’.Thisdocumentisavailableonfiberplex.comorcanbeobtainedbyrequestingitfrom
[email protected]orcalling301.604.0100.
Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterial
canberecycled.Recyclingpackingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedto
disposeofthetransportpackingmaterials,recyclingisencouraged.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellassubstancesthatmustbedisposedof
professionally.Pleasedisposeofusedequipmentviaanauthorizedspecialistdealerorviathepublicwaste
disposalsystem,ensuringanymaterialthatcanberecycledhasbeen.Pleasetakecarethatyourused
equipmentcannotbeabused.Afterhavingdisconnectedyourusedequipmentfromthemainssupply,make
surethatthemainsconnectorandthemainscablearemadeuseless.
Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeof
publication.However,noliabilityisassumedbyFiberPlexforinaccuracies,errors,oromissions,norforlossor
damageresultingeitherdirectlyorindirectlyfromuseoftheinformationcontainedherein.
Introduction
TheFiberPlexTechnologiesRMC2101/RMC3101/RMC3102chassisarestandard19”rackmountable
chassis.Eachchassisprovidesuptonine(9)availableslotsforanyFiberPlexfiberopticisolator(FOI)or
telephonedisconnectunit.Notethatthesize3andTDUunitswillnotfitintheRMC2101chassis.
Thetenthavailableslotmustbeoccupiedbyapowersupplymodule.Eachchassiswillbeshippedwithone
powersupplymodule(PSM).Asecondpowersupplymodulemayalsobeaddedforsystempower
redundancy,leavingeight(8)availableslotsfortheinstallationvariouscombinationsofFOIunits.Ifthefirst
powersupplymodulefails,thesecondwillassumetheentiresystemloadandcarryonnormally.Thefailed
powersupplymodulemaybehotswappedwithanewonewithoutinterruptionofFOIoperation.
EachFOImustbematedtoachassismountadapter(CMA),whichinterfacestheFOIwiththeslotandassures
correctalignmentoftheisolatorpowerconnectorandthechassispowerbus.
KeyFeatures
Uptoninefiberopticisolatorsmaybemountedperchassis.
EachfiberopticisolatorisaccessibleandremovablethroughthefrontofthechassisintheRMC
3101andontherearintheRMC2101.
OnePSM2010or‐3010powersupplyandpowercordisincludedwithchassis.
Powerredundancyisavailablethroughanoptionalsecondpowersupplymodule.
AcablebayisprovidedbelowthemodulebayforcableroutingontheRMC3101andRMC3102.
Enhancedairflowthroughtwoexhaustfansandaventedpanel.
ChassisModelOverview
Thefollowingtableisasummaryofthevariouschassismodelsandfeatures.
ModelNumber
RFISuppressed
Power
RackHeight
STOpticalPatch
Panel
Accommodate
Size2&4FOI
Models
Accommodate
Size3FOIand
TDUModels
PowerSupply
Model
(1included)
ChassisMount
Adapter
(soldseparately)
RMC21012U XPSM2010CMA2001
RMC2101RX2U XPSM2010CMA2001
RMC31013U XXPSM3010CMA3002
RMC3101RX3U XXPSM3010CMA3002
RMC31023UXXXPSM3010CMA3002
RMC3102RX3UXXXPSM3010CMA3002
GettingStarted
InitialInspection
Immediatelyuponreceipt,inspecttheshippingcontainerfordamage.Thecontainershouldberetaineduntil
theshipmenthasbeencheckedforcompletenessandtheequipmenthasbeencheckedmechanicallyand
electrically.Iftheshipmentisincomplete,ifthereismechanicaldamage,oriftheunitfailstooperatenotify
FiberPlexandmaketheshippingmaterialsavailableforthecarrier'sinspection.
ChassisMounting
Mounttheemptychassisusingfastenersappropriatetoyourstandard19”rackenclosure.Allfour(4)
mountingpointsMUSTbeutilized.Ensurethatthereexistsadequateclearanceforfrontandrearventilation.
Thechassisshouldbelocatedinanenvironmentwhereanambienttemperaturebetweenand50°Ccanbe
maintained.
Atypical78inchequipmentrackshouldbelimitedtoamaximumof17RMC2101chassis.Whenthemodel
RMC3101ispreferred,theninstallationofamaximumof12unitsisadvised.Theworstcaseheatdissipation
for17unitsis2.3kWtotal;forcedairrackventilationisrecommended.
PowerRequirements&PSMMounting
Thepowersupplymodules(PSM2010/PSM3010)acceptvoltagesfrom100240VAC,50/60Hz.Maximum
powerconsumptionis125Wpermodule.Althoughthepowersupplymodulesaredesignedtobehot
swappable,itisoptimalpracticetoinsertamoduleintothechassispriortotheapplicationofACpower.The
powersuppliesmustbeinstalledintheslotleftmostslotwhenviewingtheinsertionendoftherespective
modelchassis.Asecondaryredundantpowersupplymaybeinstalledinthenextslottotheright.
Toaccessthefuses,disconnectpowercord,andremovethepowersupplyunitfromthechassis.Replacement
fusesmusthavetherequiredcurrentratingandmustbeofthespecifiedtype.Useofrepairedfusesand/or
bypassofthefuseholdersisnotrecommendedandwillvoidthewarranty.
Thesystempowerrequirementfora17unit(maximum)rackconfigurationis115VAC@20Amps;ifsupplied
with230VAC,10Ampsisrequired.
Figure1PSM2010installintotheRMC2101fromtherear
Figure2PSM3010installintotheRMC3101fromthefront
PowerSupplyModuleFuseReplacement
Thepowersupplymodulesareeachprotectedbyasingle2Atimedelayfuse(Littlefusemodel218.002Slo
Blo).Replacementofthefuserequiresthepowercordtobedisconnectedfromthepowersupplypowerinlet.
Slideopentheintegralfuseholder,removetheblownfuseandreplace.Asparefuseisstoredontheouter
positionofthefuseholder.
Replaceonlywithidenticalorequivalenttimedelayfuse.
Figure3FusereplacementinboththePSM2010andPSM3010
InsertingFOIModules
Whenchassismountingisdesired,theisolatormustfirstbeattachedtoaChassisMountingAdapter(CMA).
TwoCMAmodelsareavailable.ModelCMA2001providesforFOIinstallationwithintheRMC2101chassis
andthemodelCMA3002providesinstallationwithintheRMC3101andRMC3102chassis.BothCMAmodels
attachtotheisolatormoduleinanidenticalmanner.TwomountingholesontheCMAbaseplateflangealign
withcorrespondingthreadedholeslocatedontheisolatormoduleabovethepowerjack.One(1)threaded
bananaplugandone(1)632threadPhillipspanheadscrewaresuppliedtomatetheFOItotheadapter.
TheFOIunitmaynowbeinsertedintoanyavailableslot.TheCMAwillinsureperfectalignmentoftheFOIand
thechassisbackplaneconnector.

Figure4
A
ttachFOItoappropriateCMAusingbananaplugandPhilipsscre
w
Figure5FOIinstallsintotheRMC2101fromtherear
Figure6FOIinstallsintotheRMC3101fromthefront

Features
RMC2101FrontFeatures
Figure7RMC2101FrontFace
ChassisVentilationFans(x2)Thesefansprovideforcedaircoolingtothemountedcomponents.
RMC2101RearFeatures
Figure8RMC2101RearFace
PowerSupplyInstallationPositions(x2)Thefirsttwochassispositionsarespacedappropriatelyfor
theinstallationofredundantPSM2010powersupplies,whicharehotswappable.FOImodulescanbe
placedinthispositionifonlyasinglepowersupplyisusedallowingforatotalof9FOImodules.
FOIModuleInstallationPositions(x8)Theremainingpositionsarespacedappropriatelyforthe
installationofupto8FOImodulesontheirCMA2001adapterplates.
CardGuides,UpperandLowerPowersupplyandFOImodulesarealignedwiththeguidesfor
properinsertionwiththematingconnectorsinthechassiswall.
ModuleGroundingandRetentionFittingAllmodulesareequippedwithagroundinglugwhich
engagesblindintothisjackuponinstallation.Thisalsoaidsretentionofeachmodulewithinthe
chassis.
PowerConnectorJackDCpoweristappedfromthepowersuppliesanddistributedtotheFOIunits
viatheseconnectorsonasinglebus.Designedfortheblindmatingapplication,theinterfaceprovides
retentionoftheunitsaswell.
1
2
3
4
5
6
RMC3101FrontFeatureswithCover
Figure9RMC3101FrontFacewithCoverInstalled
FrontCoverRetentionThumbscrews(x2)Apairofknurledthumbscrewsallowaccesstothemodule
mountingcavitywithouttheuseoftools.Toremove,turnCCWtoloosen,thencontinuetorotatethe
innerretentionleverstodisengagethemountingblocks.Installationofthefrontcoverrequiresalignmentof
theretentionleverstocleartheinnerblockspriortoreplacementofthecover.
FrontVentilationOpeningsTheseshallbekeptclearofdebris,papers,labels,etc.toallowcooling
airflowrequiredbythechassiscomponents.
RMC3101RearFace
Figure10RMC3101RearFace
ChassisVentilationFans(x2)Thesefansprovideforcedaircoolingtothemountedcomponents.

GroundingLugs(x2)Provisionedforafunctionalchassisgroundfromeitherside,thegrounding
pointsareeitherleftorright.Theunitshipswithhardwareontherightside.
CableRoutingTrayCableandopticalfiberrunsmaybelaidheretoclearthecoolingfanassembly.
Allowsforcleanrearexitofallcables.
1
2
8
9
10
RMC3101FrontwithoutCover
Figure11RMC3101FrontFace,CoverRemoved
PowerSupplyInstallationPositions(x2)Thefirsttwochassispositionsarespacedappropriatelyfor
theinstallationofredundantPSM3010powersupplies,whicharehotswappable.FOImodulescanbe
placedinthispositionifonlyasinglepowersupplyisusedallowingforatotalof9FOImodules.
FOIModuleInstallationPositions(x8)Theremainingpositionsarespacedappropriatelyforthe
installationofupto8FOImodulesontheirCMA3002adapterplates.
CardGuides,UpperandLowerPowersupplyandFOImodulesarealignedwiththeguidesfor
properinsertionwiththematingconnectorsinthechassiswall.
ModuleGroundingandRetentionFittingAllmodulesareequippedwithagroundinglugwhich
engagesblindintothisjackuponinstallation.Thisalsoaidsretentionofeachmodulewithinthe
chassis.
PowerConnectorJackDCpoweristappedfromthepowersuppliesanddistributedtotheFOIunits
viatheseconnectorsonasinglebus.Designedfortheblindmatingapplication,theinterfaceprovides
retentionoftheunitsaswell.

3
4
5
6
7
PSM2010/3010FrontFace
Figure12PSM2010FrontFace
PowerStatusLEDIndicatesDCoutputforthepowersupply.AgreenLEDindicatespowergood.An
audiblealarmwillsoundifonesupplyinaredundantsystemhasfailed.
FuseAccessPanelAllowsaccesstothe5x20mmfuse.TheACpowerpathisinterruptedwheninthe
openposition.
ACMainsPowerInletConformingtoIEC320,standardpowercordsareattachedhere.
PSM2010/3010RearFace
Figure13PSM2010RearFace
PowerSupplyGroundingPlugPomonatypeplugprovidesafunctionalgroundandaidsretentionof
themodulewithinthechassis.
PowerConnectorPlugDCoutputtothechassisbus;thisalsoprovidesretentionofthepowersupply
intheinstalledposition.

1
2
3
4
5
Specifications
RMC2101
Figure14RMC2101Dimensions

FANSPECIFICATIONS
MinTypMaxUnit
FanSpeed‐2500‐RPM
AirPressure‐ ‐ 3.5mmH2O
‐ ‐ 0.14inH2O
AirFlow‐ 50.5‐CFM
‐ 1.43‐m3/min
Noise‐34‐dBA@1m
PHYSICALSPECIFICATIONS
CaseDimensionsRackSpacesLengthWidthHeightWeight
RMC21012U11.35in(288mm)19in(483mm)3.5in(89mm)16lb(7.25kg)
RMC3101
Figure15RMC3101Dimensions
FANSPECIFICATIONS
MinTypMaxUnit
FanSpeed‐2500‐RPM
AirPressure‐ ‐ 3.5mmH2O
‐ ‐ 0.14inH2O
AirFlow‐ 50.5‐CFM
‐ 1.43‐m3/min
Noise‐34‐dBA@1m
PHYSICALSPECIFICATIONS
CaseDimensionsRackSpacesLengthWidthHeightWeight
RMC31013U12.75in(234mm)19in(483mm)5.25in(133mm)22lb(10kg)
PSM2010
Figure16PSM2010OverallDimensions

PSM3010
Figure17PSM3010OverallDimensions

ELECTRICALSPECIFICATIONS
MinTypMaxUnit
Input
Voltage100‐240VAC
Frequency50‐60Hz
Power‐125W
Output
Voltage‐9‐VDC
SupplyCurrent‐8.3A
Power‐76.5W
ENVIRONMENTALSPECIFICATIONS
MinTypMaxUnit
StorageTemperature‐40‐85°C
OperatingTemperature0‐50°C
PHYSICALSPECIFICATIONS
CaseDimensionsLengthWidthHeightWeight
PSM20106.375in(162mm)1.57in(40mm)2.84in(72mm)1.6lb(0.7kg)
PSM30109.56in(243mm)1.57in(40mm)3.49in(88mm)1.6lb(0.7kg)
18040-412 Guilford Rd. • Annapolis Junction, MD 20701
fiberplex.com • [email protected]
• 301.604.0100
UMRMC3010
150303
/