Fiberplex RMC-3101 User manual

Type
User manual

This manual is also suitable for


USERMANUAL
RackMountChassis
RMC2101/RMC3101/RMC3102
WarningforYourProtection
1.Readtheseinstructions.
2.Keeptheseinstructions.
3.Heedallwarnings.
4.Followallinstructions.
5.Donotusethisapparatusnearwater.
6.Cleanonlywithadrycloth.
7.Donotblockanyoftheventilationopenings.Installinaccordancewiththemanufacturer’sinstructions.
8.Donotinstallnearanyheatsourcessuchasradiators,heatregisters,stoves,orotherapparatus(includingamplifiers)thatproduceheat.
9.Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
10.Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
11.Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushasbeendamagedinanyway,suchaspowersupply
cordorplugisdamaged,liquidhasbeenspilledorobjectshavefallenintotheapparatus,theapparatushasbeenexposedtorainormoisture,does
notoperatenormally,orhasbeendropped.
Theapparatusshallnotbeexposedtodrippingorsplashing.Noobjectsfilledwithliquids,suchasvases,shallbeplacedontheapparatus.
“WARNING:Toreducetheriskoffireorelectricshock,donotexposethisapparatustorainormoisture.”
GeneralInstallationInstructions
Pleaseconsiderthesegeneralinstructionsinadditiontoanyproductspecificinstructionsinthe“Installation”chapterofthismanual.
Unpacking
Checktheequipmentforanytransportdamage.Iftheunitismechanicallydamaged,ifliquidshavebeenspilledorifobjectshavefallenintothe
unit,itmustnotbeconnectedtotheACpoweroutlet,oritmustbeimmediatelydisconnectedbyunpluggingthepowercable.Repairmustonlybe
performedbytrainedpersonnelinaccordancewiththeapplicableregulations.
InstallationSite
Installtheunitinaplacewherethefollowingconditionsaremet:
Thetemperatureandtherelativehumidityoftheoperatingenvironmentmustbewithinthespecifiedlimitsduringoperationofthe
unit.Valuesspecifiedareapplicabletotheairinletsoftheunit.
Condensationmaynotbepresentduringoperation.Iftheunitisinstalledinalocationsubjecttolargevariationsofambient
temperature(e.g.inanOBvan),appropriateprecautionsmustbetaken.
Unobstructedairflowisessentialforproperoperation.Ventilationopeningsoftheunitareafunctionalpartofthedesignandmust
notbeobstructedinanywayduringoperation(e.g.‐byobjectsplaceduponthem,placementoftheunitonasoftsurface,or
improperinstallationoftheunitwithinarackorpieceoffurniture).
Theunitmustnotbeundulyexposedtoexternalheatsources(directsunlight,spotlights).
AmbientTemperature
UnitsandsystemsbyFiberPlexaregenerallydesignedforanambienttemperaturerange(i.e.temperatureoftheincomingair)of+5...+40°C.
Whenrackmountingtheunits,thefollowingfactsmustbeconsidered:
Thepermissibleambienttemperaturerangeforoperationofthesemiconductorcomponentsis0°Cto+70°C(commercial
temperaturerangeforoperation).
Theairflowthroughtheinstallationmustallowexhaustairtoremaincoolerthan70°Catalltimes.
Averagetemperatureincreaseofthecoolingairshallbeabout20C°,allowingforanadditionalmaximum10increaseatthe
hottestcomponents.
Ifthecoolingfunctionoftheinstallationmustbemonitored(e.g.forfanfailureorilluminationwithspotlamps),theexhaustairtemperaturemust
bemeasureddirectlyabovethemodulesatseveralplaceswithintheenclosure.
GroundingandPowerSupply
Groundingofunitswithmainssupply(classIequipment)isperformedviatheprotectiveearth(PE)conductorintegratedinthemainscable.Units
withbatteryoperation(<60V,classIIIequipment)mustbeearthedseparately.Groundingtheunitisoneofthemeasuresforprotectionagainst
electricalshockhazard(dangerousbodycurrents).Hazardousvoltagemaynotonlybecausedbydefectivepowersupplyinsulation,butmayalso
beintroducedbytheconnectedaudioorcontrolcables.
Thisequipmentmayrequiretheuseofadifferentlinecord,attachmentplug,orboth,dependingontheavailablepowersourceatinstallation.If
theattachmentplugneedstobechanged,referservicingtoqualifiedpersonnel.
ClassIEquipment(MainsOperation)
Shouldtheequipmentbedeliveredwithoutamatchingmainscable,thelatterhastobepreparedbyatrainedpersonusingtheattachedfemale
plug(IEC320/C13orIEC320/C19)withrespecttotheapplicableregulationsinyourcountry.
BeforeconnectingtheequipmenttotheACpoweroutlet,checkthatthelocallinevoltagematchestheequipmentrating(voltage,frequency)
withintheadmissibletolerance.Theequipmentfusesmustberatedinaccordancewiththespecificationsontheequipment.
Equipmentsuppliedwitha3poleapplianceinlet(protectionconformingtoclassIequipment)mustbeconnectedtoa3poleACpoweroutletso
thattheequipmentcabinetisconnectedtotheprotectiveearth.
WARNING:
Ifthegroundisdefeated,certainfaultconditionsintheunitorinthesystemtowhichitisconnected
canresultinfulllinevoltagebetweenchassisandearthground.Severeinjuryordeathcanthenresult
ifthechassisandearthgroundaretouchedsimultaneously.
Warranty,ServiceandTermsandConditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsof
Sale’.Thisdocumentisavailableonfiberplex.comorcanbeobtainedbyrequestingitfrom
[email protected]orcalling301.604.0100.
Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterial
canberecycled.Recyclingpackingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedto
disposeofthetransportpackingmaterials,recyclingisencouraged.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellassubstancesthatmustbedisposedof
professionally.Pleasedisposeofusedequipmentviaanauthorizedspecialistdealerorviathepublicwaste
disposalsystem,ensuringanymaterialthatcanberecycledhasbeen.Pleasetakecarethatyourused
equipmentcannotbeabused.Afterhavingdisconnectedyourusedequipmentfromthemainssupply,make
surethatthemainsconnectorandthemainscablearemadeuseless.
Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeof
publication.However,noliabilityisassumedbyFiberPlexforinaccuracies,errors,oromissions,norforlossor
damageresultingeitherdirectlyorindirectlyfromuseoftheinformationcontainedherein.
Introduction
TheFiberPlexTechnologiesRMC2101/RMC3101/RMC3102chassisarestandard19”rackmountable
chassis.Eachchassisprovidesuptonine(9)availableslotsforanyFiberPlexfiberopticisolator(FOI)or
telephonedisconnectunit.Notethatthesize3andTDUunitswillnotfitintheRMC2101chassis.
Thetenthavailableslotmustbeoccupiedbyapowersupplymodule.Eachchassiswillbeshippedwithone
powersupplymodule(PSM).Asecondpowersupplymodulemayalsobeaddedforsystempower
redundancy,leavingeight(8)availableslotsfortheinstallationvariouscombinationsofFOIunits.Ifthefirst
powersupplymodulefails,thesecondwillassumetheentiresystemloadandcarryonnormally.Thefailed
powersupplymodulemaybehotswappedwithanewonewithoutinterruptionofFOIoperation.
EachFOImustbematedtoachassismountadapter(CMA),whichinterfacestheFOIwiththeslotandassures
correctalignmentoftheisolatorpowerconnectorandthechassispowerbus.
KeyFeatures
Uptoninefiberopticisolatorsmaybemountedperchassis.
EachfiberopticisolatorisaccessibleandremovablethroughthefrontofthechassisintheRMC
3101andontherearintheRMC2101.
OnePSM2010or‐3010powersupplyandpowercordisincludedwithchassis.
Powerredundancyisavailablethroughanoptionalsecondpowersupplymodule.
AcablebayisprovidedbelowthemodulebayforcableroutingontheRMC3101andRMC3102.
Enhancedairflowthroughtwoexhaustfansandaventedpanel.
ChassisModelOverview
Thefollowingtableisasummaryofthevariouschassismodelsandfeatures.
ModelNumber
RFISuppressed
Power
RackHeight
STOpticalPatch
Panel
Accommodate
Size2&4FOI
Models
Accommodate
Size3FOIand
TDUModels
PowerSupply
Model
(1included)
ChassisMount
Adapter
(soldseparately)
RMC21012U XPSM2010CMA2001
RMC2101RX2U XPSM2010CMA2001
RMC31013U XXPSM3010CMA3002
RMC3101RX3U XXPSM3010CMA3002
RMC31023UXXXPSM3010CMA3002
RMC3102RX3UXXXPSM3010CMA3002
GettingStarted
InitialInspection
Immediatelyuponreceipt,inspecttheshippingcontainerfordamage.Thecontainershouldberetaineduntil
theshipmenthasbeencheckedforcompletenessandtheequipmenthasbeencheckedmechanicallyand
electrically.Iftheshipmentisincomplete,ifthereismechanicaldamage,oriftheunitfailstooperatenotify
FiberPlexandmaketheshippingmaterialsavailableforthecarrier'sinspection.
ChassisMounting
Mounttheemptychassisusingfastenersappropriatetoyourstandard19”rackenclosure.Allfour(4)
mountingpointsMUSTbeutilized.Ensurethatthereexistsadequateclearanceforfrontandrearventilation.
Thechassisshouldbelocatedinanenvironmentwhereanambienttemperaturebetweenand50°Ccanbe
maintained.
Atypical78inchequipmentrackshouldbelimitedtoamaximumof17RMC2101chassis.Whenthemodel
RMC3101ispreferred,theninstallationofamaximumof12unitsisadvised.Theworstcaseheatdissipation
for17unitsis2.3kWtotal;forcedairrackventilationisrecommended.
PowerRequirements&PSMMounting
Thepowersupplymodules(PSM2010/PSM3010)acceptvoltagesfrom100240VAC,50/60Hz.Maximum
powerconsumptionis125Wpermodule.Althoughthepowersupplymodulesaredesignedtobehot
swappable,itisoptimalpracticetoinsertamoduleintothechassispriortotheapplicationofACpower.The
powersuppliesmustbeinstalledintheslotleftmostslotwhenviewingtheinsertionendoftherespective
modelchassis.Asecondaryredundantpowersupplymaybeinstalledinthenextslottotheright.
Toaccessthefuses,disconnectpowercord,andremovethepowersupplyunitfromthechassis.Replacement
fusesmusthavetherequiredcurrentratingandmustbeofthespecifiedtype.Useofrepairedfusesand/or
bypassofthefuseholdersisnotrecommendedandwillvoidthewarranty.
Thesystempowerrequirementfora17unit(maximum)rackconfigurationis115VAC@20Amps;ifsupplied
with230VAC,10Ampsisrequired.
Figure1PSM2010installintotheRMC2101fromtherear
Figure2PSM3010installintotheRMC3101fromthefront
PowerSupplyModuleFuseReplacement
Thepowersupplymodulesareeachprotectedbyasingle2Atimedelayfuse(Littlefusemodel218.002Slo
Blo).Replacementofthefuserequiresthepowercordtobedisconnectedfromthepowersupplypowerinlet.
Slideopentheintegralfuseholder,removetheblownfuseandreplace.Asparefuseisstoredontheouter
positionofthefuseholder.
Replaceonlywithidenticalorequivalenttimedelayfuse.
Figure3FusereplacementinboththePSM2010andPSM3010
InsertingFOIModules
Whenchassismountingisdesired,theisolatormustfirstbeattachedtoaChassisMountingAdapter(CMA).
TwoCMAmodelsareavailable.ModelCMA2001providesforFOIinstallationwithintheRMC2101chassis
andthemodelCMA3002providesinstallationwithintheRMC3101andRMC3102chassis.BothCMAmodels
attachtotheisolatormoduleinanidenticalmanner.TwomountingholesontheCMAbaseplateflangealign
withcorrespondingthreadedholeslocatedontheisolatormoduleabovethepowerjack.One(1)threaded
bananaplugandone(1)632threadPhillipspanheadscrewaresuppliedtomatetheFOItotheadapter.
TheFOIunitmaynowbeinsertedintoanyavailableslot.TheCMAwillinsureperfectalignmentoftheFOIand
thechassisbackplaneconnector.

Figure4
A
ttachFOItoappropriateCMAusingbananaplugandPhilipsscre
w
Figure5FOIinstallsintotheRMC2101fromtherear
Figure6FOIinstallsintotheRMC3101fromthefront

Features
RMC2101FrontFeatures
Figure7RMC2101FrontFace
ChassisVentilationFans(x2)Thesefansprovideforcedaircoolingtothemountedcomponents.
RMC2101RearFeatures
Figure8RMC2101RearFace
PowerSupplyInstallationPositions(x2)Thefirsttwochassispositionsarespacedappropriatelyfor
theinstallationofredundantPSM2010powersupplies,whicharehotswappable.FOImodulescanbe
placedinthispositionifonlyasinglepowersupplyisusedallowingforatotalof9FOImodules.
FOIModuleInstallationPositions(x8)Theremainingpositionsarespacedappropriatelyforthe
installationofupto8FOImodulesontheirCMA2001adapterplates.
CardGuides,UpperandLowerPowersupplyandFOImodulesarealignedwiththeguidesfor
properinsertionwiththematingconnectorsinthechassiswall.
ModuleGroundingandRetentionFittingAllmodulesareequippedwithagroundinglugwhich
engagesblindintothisjackuponinstallation.Thisalsoaidsretentionofeachmodulewithinthe
chassis.
PowerConnectorJackDCpoweristappedfromthepowersuppliesanddistributedtotheFOIunits
viatheseconnectorsonasinglebus.Designedfortheblindmatingapplication,theinterfaceprovides
retentionoftheunitsaswell.
1
2
3
4
5
6
RMC3101FrontFeatureswithCover
Figure9RMC3101FrontFacewithCoverInstalled
FrontCoverRetentionThumbscrews(x2)Apairofknurledthumbscrewsallowaccesstothemodule
mountingcavitywithouttheuseoftools.Toremove,turnCCWtoloosen,thencontinuetorotatethe
innerretentionleverstodisengagethemountingblocks.Installationofthefrontcoverrequiresalignmentof
theretentionleverstocleartheinnerblockspriortoreplacementofthecover.
FrontVentilationOpeningsTheseshallbekeptclearofdebris,papers,labels,etc.toallowcooling
airflowrequiredbythechassiscomponents.
RMC3101RearFace
Figure10RMC3101RearFace
ChassisVentilationFans(x2)Thesefansprovideforcedaircoolingtothemountedcomponents.

GroundingLugs(x2)Provisionedforafunctionalchassisgroundfromeitherside,thegrounding
pointsareeitherleftorright.Theunitshipswithhardwareontherightside.
CableRoutingTrayCableandopticalfiberrunsmaybelaidheretoclearthecoolingfanassembly.
Allowsforcleanrearexitofallcables.
1
2
8
9
10
RMC3101FrontwithoutCover
Figure11RMC3101FrontFace,CoverRemoved
PowerSupplyInstallationPositions(x2)Thefirsttwochassispositionsarespacedappropriatelyfor
theinstallationofredundantPSM3010powersupplies,whicharehotswappable.FOImodulescanbe
placedinthispositionifonlyasinglepowersupplyisusedallowingforatotalof9FOImodules.
FOIModuleInstallationPositions(x8)Theremainingpositionsarespacedappropriatelyforthe
installationofupto8FOImodulesontheirCMA3002adapterplates.
CardGuides,UpperandLowerPowersupplyandFOImodulesarealignedwiththeguidesfor
properinsertionwiththematingconnectorsinthechassiswall.
ModuleGroundingandRetentionFittingAllmodulesareequippedwithagroundinglugwhich
engagesblindintothisjackuponinstallation.Thisalsoaidsretentionofeachmodulewithinthe
chassis.
PowerConnectorJackDCpoweristappedfromthepowersuppliesanddistributedtotheFOIunits
viatheseconnectorsonasinglebus.Designedfortheblindmatingapplication,theinterfaceprovides
retentionoftheunitsaswell.

3
4
5
6
7
PSM2010/3010FrontFace
Figure12PSM2010FrontFace
PowerStatusLEDIndicatesDCoutputforthepowersupply.AgreenLEDindicatespowergood.An
audiblealarmwillsoundifonesupplyinaredundantsystemhasfailed.
FuseAccessPanelAllowsaccesstothe5x20mmfuse.TheACpowerpathisinterruptedwheninthe
openposition.
ACMainsPowerInletConformingtoIEC320,standardpowercordsareattachedhere.
PSM2010/3010RearFace
Figure13PSM2010RearFace
PowerSupplyGroundingPlugPomonatypeplugprovidesafunctionalgroundandaidsretentionof
themodulewithinthechassis.
PowerConnectorPlugDCoutputtothechassisbus;thisalsoprovidesretentionofthepowersupply
intheinstalledposition.

1
2
3
4
5
Specifications
RMC2101
Figure14RMC2101Dimensions

FANSPECIFICATIONS
MinTypMaxUnit
FanSpeed‐2500‐RPM
AirPressure‐ ‐ 3.5mmH2O
‐ ‐ 0.14inH2O
AirFlow‐ 50.5‐CFM
‐ 1.43‐m3/min
Noise‐34‐dBA@1m
PHYSICALSPECIFICATIONS
CaseDimensionsRackSpacesLengthWidthHeightWeight
RMC21012U11.35in(288mm)19in(483mm)3.5in(89mm)16lb(7.25kg)
RMC3101
Figure15RMC3101Dimensions
FANSPECIFICATIONS
MinTypMaxUnit
FanSpeed‐2500‐RPM
AirPressure‐ ‐ 3.5mmH2O
‐ ‐ 0.14inH2O
AirFlow‐ 50.5‐CFM
‐ 1.43‐m3/min
Noise‐34‐dBA@1m
PHYSICALSPECIFICATIONS
CaseDimensionsRackSpacesLengthWidthHeightWeight
RMC31013U12.75in(234mm)19in(483mm)5.25in(133mm)22lb(10kg)
PSM2010
Figure16PSM2010OverallDimensions

PSM3010
Figure17PSM3010OverallDimensions

ELECTRICALSPECIFICATIONS
MinTypMaxUnit
Input
Voltage100‐240VAC
Frequency50‐60Hz
Power‐125W
Output
Voltage‐9‐VDC
SupplyCurrent‐8.3A
Power‐76.5W
ENVIRONMENTALSPECIFICATIONS
MinTypMaxUnit
StorageTemperature‐40‐85°C
OperatingTemperature0‐50°C
PHYSICALSPECIFICATIONS
CaseDimensionsLengthWidthHeightWeight
PSM20106.375in(162mm)1.57in(40mm)2.84in(72mm)1.6lb(0.7kg)
PSM30109.56in(243mm)1.57in(40mm)3.49in(88mm)1.6lb(0.7kg)
18040-412 Guilford Rd. • Annapolis Junction, MD 20701
fiberplex.com • [email protected]
• 301.604.0100
UMRMC3010
150303
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Fiberplex RMC-3101 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI