Fiberplex TD-5401, FOI-5401 User manual

  • Hello, I've reviewed the user manual for the FiberPlex Fiber Transceiver FOI-5401 and TD-5401. This document details the features, installation, and operational guidelines for these fiber optic communication devices. Notably, the manual highlights the difference in build between the FOI-5401 for military use and the TD-5401 for commercial settings. I am ready to help you with any questions you have about these devices.
  • What is the difference between the FOI-5401 and TD-5401?
    What data rates are supported?
    Can these devices be used in high electrical noise environments?

USERMANUAL
T1FiberTransceiver
FOI‐5401/TD‐5401
WarningforYourProtection
1.Readtheseinstructions.
2.Keeptheseinstructions.
3.Heedallwarnings.
4.Followallinstructions.
5.Donotusethisapparatusnearwater.
6.Cleanonlywithadrycloth.
7.Donotblockanyoftheventilationopenings.Installinaccordancewiththemanufacturer’sinstructions.
8.Donotinstallnearanyheatsourcessuchasradiators,heatregisters,stoves,orotherapparatus(includingamplifiers)thatproduceheat.
9.Donotdefeatthesafetypurposeofthepolarizedorgrounding‐typeplug.Apolarizedplughastwobladeswithonewiderthantheother.A
groundingtypeplughastwobladesandathirdgroundingprong.Thewidebladeorthethirdprongisprovidedforyoursafety.Iftheprovidedplug
doesnotfitintoyouroutlet,consultanelectricianforreplacementoftheobsoleteoutlet.
10.Protectthepowercordfrombeingwalkedonorpinched,particularlyatplugs,conveniencereceptacles,andthepointwheretheyexitfromthe
apparatus.
11.Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
12.Useonlywiththecart,stand,tripod,bracket,ortablespecifiedbythemanufacturer,orsoldwiththeapparatus.Whenacartisused,use
cautionwhenmovingthecart/apparatuscombinationtoavoidinjuryfromtip‐over.
13.Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
14.Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushasbeendamagedinanyway,suchaspower‐supply
cordorplugisdamaged,liquidhasbeenspilledorobjectshavefallenintotheapparatus,theapparatushasbeenexposedtorainormoisture,does
notoperatenormally,orhasbeendropped.
Theapparatusshallnotbeexposedtodrippingorsplashing.Noobjectsfilledwithliquids,suchasvases,shallbeplacedontheapparatus.
“WARNING:Toreducetheriskoffireorelectricshock,donotexposethisapparatustorainormoisture.”
GeneralInstallationInstructions
Pleaseconsiderthesegeneralinstructionsinadditiontoanyproduct‐specificinstructionsinthe“Installation”chapterofthismanual.
Unpacking
Checktheequipmentforanytransportdamage.Iftheunitismechanicallydamaged,ifliquidshavebeenspilledorifobjectshavefallenintothe
unit,itmustnotbeconnectedtotheACpoweroutlet,oritmustbeimmediatelydisconnectedbyunpluggingthepowercable.Repairmustonlybe
performedbytrainedpersonnelinaccordancewiththeapplicableregulations.
InstallationSite
Installtheunitinaplacewherethefollowingconditionsaremet:
Thetemperatureandtherelativehumidityoftheoperatingenvironmentmustbewithinthespecifiedlimitsduringoperationofthe
unit.Valuesspecifiedareapplicabletotheairinletsoftheunit.
Condensationmaynotbepresentduringoperation.Iftheunitisinstalledinalocationsubjecttolargevariationsofambient
temperature(e.g.inanOB‐van),appropriateprecautionsmustbetaken.
Unobstructedairflowisessentialforproperoperation.Ventilationopeningsoftheunitareafunctionalpartofthedesignandmust
notbeobstructedinanywayduringoperation(e.g.‐byobjectsplaceduponthem,placementoftheunitonasoftsurface,or
improperinstallationoftheunitwithinarackorpieceoffurniture).
Theunitmustnotbeundulyexposedtoexternalheatsources(directsunlight,spotlights).
AmbientTemperature
UnitsandsystemsbyFiberPlexaregenerallydesignedforanambienttemperaturerange(i.e.temperatureoftheincomingair)of5°Cto40°C(41
°Fto104°F).Whenrackmountingtheunits,thefollowingfactsmustbeconsidered:
Thepermissibleambienttemperaturerangeforoperationofthesemiconductorcomponentsis0°Cto+70°C(32°Fto158°F)
(commercialtemperaturerangeforoperation).
Theairflowthroughtheinstallationmustallowexhaustairtoremaincoolerthan70°C(158°F)atalltimes.
Averagetemperatureincreaseofthecoolingairshallbeabout20°C(68°F),allowingforanadditionalmaximum10°Cincreaseat
thehottestcomponents.
Ifthecoolingfunctionoftheinstallationmustbemonitored(e.g.forfanfailureorilluminationwithspotlamps),theexhaustairtemperaturemust
bemeasureddirectlyabovethemodulesatseveralplaceswithintheenclosure.
GroundingandPowerSupply
Groundingofunitswithmainssupply(ClassIequipment)isperformedviatheprotectiveearth(PE)conductorintegratedinthree‐pinPhoenix™
connector.Unitswithbatteryoperation(<60V,ClassIIIequipment)mustbeearthedseparately.Groundingtheunitisoneofthemeasuresfor
protectionagainstelectricalshockhazard(dangerousbodycurrents).Hazardousvoltagemaynotonlybecausedbydefectivepowersupply
insulation,butmayalsobeintroducedbytheconnectedaudioorcontrolcables.
Thisequipmentmayrequiretheuseofadifferentlinecord,attachmentplug,orboth,dependingontheavailablepowersourceatinstallation.If
theattachmentplugneedstobechanged,referservicingtoqualifiedpersonnel.
Warranty,ServiceandTermsandConditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsof
Sale’.Thisdocumentisavailableonfiberplex.comorcanbeobtainedbyrequestingitfrom
[email protected]orcalling301.604.0100.
Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterial
canberecycled.Recyclingpackingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedto
disposeofthetransportpackingmaterials,recyclingisencouraged.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellassubstancesthatmustbedisposedof
professionally.Pleasedisposeofusedequipmentviaanauthorizedspecialistdealerorviathepublicwaste
disposalsystem,ensuringanymaterialthatcanberecycledhasbeen.Pleasetakecarethatyourused
equipmentcannotbeabused.Afterhavingdisconnectedyourusedequipmentfromthemainssupply,make
surethatthemainsconnectorandthemainscablearemadeuseless.
Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeof
publication.However,noliabilityisassumedbyFiberPlexforinaccuracies,errors,oromissions,norforlossor
damageresultingeitherdirectlyorindirectlyfromuseoftheinformationcontainedherein.
Introduction
WhenyouneedtorealizethemanybenefitsoffiberopticcommunicationacrossaT1connection,theFOI‐
5401/TD‐5401isaperfectdrop‐insolution.Thereisnoneedtoreconfigureyourdevices;simplyplugthe
deviceateachendofyourT1lineintooneofthesemodules,andenjoyasecure,stable,andelectrically
isolatedconnection.
KeyFeatures
DataRate:1.544Mbps(T1)‐2.048(E1)
SupportsISDNPRI(PrimaryRateInterface)services,alsoknownasPRA(PrimaryRateAccess)
23B+Ddatapassestransparently
TheoryofOperation
TheFOI‐5401providescompleteelectricalisolationforT1communications.Itisfunctionallysimilartothe
obsoleteFiberPlexproduct,theFOI‐4544,thephysicaldifferencebeingthattheelectricaldataconnectionis
madethroughaRJ‐45connectorinsteadoftheDA‐15connectorontheFOI‐4544.
TheFOI‐5401isNOTbackwardcompatiblewiththeFOI‐4544.
TheFOIunitcanbeusedinareasofhighelectricalnoiseorinandoutofRFshieldedenclosures.Thefiber
opticcableisnotsusceptibletointerferencecausedbyimpulsenoise,crosstalk,orEMI.Privacyof
communicationsisalsoenhancedbecausethefiberopticcabledoesnotradiateanyemissions.
Inaddition,fiberopticcableoffersmuchlongertransmissiondistancesthancopperwiring.TraditionalT1
cablingislimitedtoamaximumdistanceof6200ft(1.89km),butmultimodeopticsontheunitcanextendthe
distanceto2km,whilesinglemodeopticscanfurtherextendthedistanceto20km.Atypicallinkconsistsof
twoFOI‐5401units,oneateachendofthenetwork,withaduplexfiberopticcablebetweenthem.
DifferencesbetweenFOI‐5401andTD‐5401
Functionally,theFOI‐5401andTD‐5401areidentical.Theonlydifferencesarethepackagingandpowersupply
compatibility.TheFOI‐5401ispartoftheFOIlineofproductsdesignedforruggedizedmilitaryapplications.It
ishousedinaRF‐shieldedcanenclosure.ForstandaloneapplicationsitcanbepoweredbyaddingaPSQ‐4909
ACsupplyoraPSQ‐4920DCpowersupply(notincluded).Optionally,upto8FOIunitscanbemountedon
CMAchassisadaptersandinstalledinanRMC‐3101orRMC‐2101rackmountchassis,whichprovide
redundantpowertotheunitsthroughacommonbackplaneconnection.
TheTD‐5401ishousedinthecommercial‘ThrowDown’packaging.Thisversionisdesignedtobeaworkhorse
unitinvariouscommercialandindustrialenvironments.Itispoweredeitherbya9VDCwalladapter(included)
orviabussedpowersuppliedthroughanintegratedthree‐pinPhoenix™connector.UptosixTD‐5401units
canbeinstalledintheoptional1UTDR‐01rackshelf.
GettingStarted
InitialInspection
Immediatelyuponreceipt,inspecttheshippingcontainerfordamage.Thecontainershouldberetaineduntil
theshipmenthasbeencheckedforcompletenessandtheequipmenthasbeencheckedmechanicallyand
electrically.Iftheshipmentisincomplete,ifthereismechanicaldamage,oriftheunitfailstooperatenotify
FiberPlexandmaketheshippingmaterialsavailableforthecarrier'sinspection.
FrontIndicators/Connections
Figure1TD‐5401(left),FOI‐5401(middle),andFOI‐5401withSTconnectors(Right)FrontFace
RJ‐45Port–UsedtoconnectyourcopperT1linetotheTD/FOI‐5401.ThisportacceptsastandardRJ‐45
maleconnector.
Pinout
PIN Signal
1 TIP
2 RING
3 ‐
4 TIP1
5 RING1
6 ‐
7 ‐
8 ‐
SFPPort–AnSFPopticaltransceivermoduleinstalledinthisportwhenorderedwiththeLCopticoption.
ApairoffiberopticcablesconnectstothesetolinktwoTD/FOI‐5401s.
STOpticalConnectors–STopticalconnectorsinplaceoftheSFPportwhenorderedwiththeSToptic
option.
Signal–LEDwhichindicatesthepresenceofareceivesignalfromtheRJ‐45port.
SignalIndicator
Off NoreceivesignaldetectedfromRJ‐45port
On Receivesignalispresent
Sync–LEDwhichindicatesthepresenceofareceivesignalfromthefiberopticline.
PowerIndicator
Off Noreceivesignaldetectedoverfiberopticline
Flashing Receivesignalispresent,butnotframe‐locked
On(Solid) Receivesignalispresentandframe‐locked
Power–LEDwhichindicatesthepresenceofDCpowerintheunit.
PowerIndicator
Off Nopowerfromtheexternalsupplyorinternalfault
On Powersupplyisoperatingproperly
RearIndicators/Connections
Figure2TD‐5401(left)andFOI‐5401(right)RearFace
CircularDCPowerConnection–DCpowerentryfortheunit.OntheFOI‐5401thisisaLemoconnector
designedtointerfacewitheitheraPSQpowermoduleorRMCchassis.OntheTD‐5401thisisastandardDC
connectionforusewiththeincludedDCwallpowersupply.
PhoenixCDPowerConnection–SecondarypoweroptionfortheTD‐5401.Thisiswiredindirectparallel
withtheCircularconnectorandhastheadditionofapositiveearthchassisgroundconnection.Thiscanbe
usedtopowertheunitonaclientsuppliedpowerbuss.
PowerRequirementsandMounting
FlexiblemountingallowstheFOI‐5401tobechassismountedorstandaloneconfiguration.Anycombinationof
8FiberPlexFOIunitscanbemountedinaRMC‐3101usingCMA‐3002chassismountadapters.TheRMC‐3101
canaccommodatehotswappedredundantpower.Alternately,theFOI‐5401canbeusedinastandalone
applicationwhenpairedwithaPSQ‐4909forfullrangeACoperationorthePSQ‐4920for12‐48VDCoperation.
 
Figure3FOIUnitwithPSQ‐4909(left)andwithCMA‐3002(right)
#2 Wood Screw, 1/2" Long, #1 Phillips
Drive
Lower TD Unit Over Screw
Heads,
Figure4InstallingaTDModuleUsing
MountingSlots
Figure6FOIunitInstalledinanRMC‐3101Chassis
Figure5TDModuleInstallationonaTDR‐01Tray
InsertingandRemovingSFPModules
IdentifytheLatchTypeoftheSFPModule
SFPModuleshavevariouslatchingmechanismstosecurethemintotheSFPCageofadevice.FiberPlexfiber
opticproductscansupportahostofmanufacturersandbrandsofSFPModules,sotheusermayencounter
anynumberofdifferentlatches.Someofthesearedescribedbelow.
BailClasp
ThebailclaspSFPmodulehasaclasp
thatyouusetoremoveorinstalltheSFP
module.
ActuatorButton
TheactuatorbuttonSFPmoduleincludesabuttonthatyou
pushinordertoremovetheSFPmodulefromaport.This
buttoncaneitherlift‘Up’orpress‘In’toreleasetheSFP
Moduledependingonthemanufacturer.
MylarTab
TheMylartabSFPmodulehasatabthat
youpulltoremovethemodulefroma
port.
SlideTab
TheslidetabSFPmodulehasatabunderneaththefrontofthe
SFPmodulethatyouusetodisengagethemodulefromaport.
HandlingWarnings
SFPModulesarestaticsensitive.Topreventdamagefromelectrostaticdischarge(ESD),itis
recommendedtoattachanESDpreventativewriststraptoyourwristandtoabaremetalsurfacewhen
youinstallorremoveanSFPModule.
DisconnectallopticalorcoppercablesfromSFPModulespriortoinstallingorremovingtheSFPModule.
Failuretodosocouldresultindamagetothecable,cableconnectorortheSFPModuleitself.Removing
andinsertinganSFPModulecanshortenitsusefullife,soyoushouldnotremoveandinsertSFPModules
anymoreoftenthanisabsolutelynecessary.
ProtectopticalSFPmodulesbyinsertingcleandustcoversintothemafterthecablesareremoved.Be
suretocleantheopticsurfacesofthefibercablesbeforeyouplugthembackintotheopticalportsof
anotherSFPmodule.AvoidgettingdustandothercontaminantsintotheopticalportsofyourSFP
modules,becausetheopticswillnotworkcorrectlywhenobstructedwithdust.
InsertingaSFPModule
1) AttachanESD‐preventative
wristoranklestrap,followingits
instructionsforuse.
2) Disconnectandremoveall
interfacecablesfromSFP
Module.
3) IftheSFPModulehasaBail
Clasp,closetheBailClaspbefore
insertingtheSFPModule.
4) Withthegoldfingerconnector
onthebottomandthelabelonthetop,lineuptheSFPModulewiththeemptycageandslideitin
makingsurethatitis completelyinsertedandseatedinthecage.
RemovingaSFPModule
1) AttachanESD‐
preventativewristor
anklestrap,followingits
instructionsforuse.
2) Disconnectandremoveallinterface
cablesfromSFPModule.
3) Releasethelatchingmechanism.
BailClasp–OpenthebailclaspontheSFP
Modulewithyourfingerinadownward
direction.
ActuatorButton–Gentlypressthe
actuatorup(orin)whilepullingthe
bodyoftheSFPModuletoreleasethe
SFPModulefromthecage.
MylarTab–Pullthetabgentlyina
straightoutwardmotionuntilit
disengagesfromtheport.Makesure
thetabisnottwistedwhenpullingasitmaybecomedisconnectedfromtheSFP
Module.
SlideTab‐Withyourthumb,pushtheslidetabonthe
bottomfrontoftheSFPmoduleinthedirectionofthe
equipmenttodisengagethemodulefromthelinecard
port.IfyoupullontheSFPmodulewithoutdisengaging
thetab,youcandamagetheSFPmodule.
4) GrasptheSFPModulebetweenyourthumbandindex
fingerandcarefullyremoveitfromtheport
5) PlacetheSFPModuleonanantistaticmat,or
immediatelyplaceitinastaticshieldingbagorcontainer
A
ctuator Button
Specifications
Figure7FOI‐5401Dimensions
Figure8TD‐5401Dimensions
Min Typ Max Unit
PowerRequirement VoltageRange 7 9 32 VDC
SupplyCurrent ‐ 600 ‐ mA
T1Interface DataRate 0.75 1.544 2.048 Mbps
LineEncoding AMI(AlternateMarkInversion)/
B8ZS(Binary8ZeroSubstitution)
InterfaceConnector RJ‐45
Environmental StorageTemperature ‐40 ‐ 85 °C
OperatingTemperature 0 ‐ 50 °C
OPTICAL SPECIFICATIONS
Order
Suffix
Connector FiberType λ
(nm)
TransmitterPower(dBm)Receiver
Sensitivity(dBm)
MaxDistance
Min Max
L22 LC/PC
Multimode 1310
‐15 ‐8 ‐24 2km
T22 ST ‐12 ‐6 ‐26 2km
L5B LC/PC
Singlemode 1310
‐9 ‐3 ‐25 20km
T5B ST ‐12 ‐6 ‐23 20km
C SFPCagewithnoOpticalModuleInstalled
ExternalSFPInterface Min Typ Max Unit
DataRate ‐ 270 ‐ Mbps
RecommendedJitter ‐ ‐  40 Psec
OperatingVoltage 3.2 3.3 3.4 VDC
MaximumCurrent ‐ ‐ 500 mA
OpticalModules SFPMSA(SFF‐8431,SFF‐8432,SFF‐8433)compliantslot,datarate266–1.25Gbps
CaseDimensions Length Width Height Weight
FOI‐5401(Size4) 4.5in(114mm) 1.453in(37mm) 2.56in(65mm) 2lb(0.9kg)
TD‐5401 4.5in(114mm) 2.75in(70mm) 1.66in(42mm) 0.4lb(0.2kg)
OtherConsiderations
SFPMSACompliance
TheSFPMulti‐SourceAgreement(MSA)isanagreementthatwasdraftedamongcompetingmanufacturersof
SFPopticalmodules.TheSFFCommitteewasformedtooverseethecreationandmaintenanceofthese
agreementsincludingtheSFPMSAdesignatedasINF‐8074i.Thisagreementdescribesamutuallyagreedupon
standardfortheformandfunctionofSFPmodules.However,notallSFPsproducedareMSAcompliant.The
MSAprovidesforatransceiver(TX/RX)pinout.OtherindustriessuchasbroadcasthadtheneedfordualTX
anddualRXSFPforunidirectionalapplicationssuchasvideo.Naturally,anon‐MSAstandardwasintroduced
allocatingpinoutassignmentsfordualoutputanddualinputI/Oconfigurations.Inaddition,thesomeofthe
internalserialcommunicationpinswerereassigned.
TheFOI/TD‐5401willonlyacceptMSAcompliantSFPModules.
ELECTRICALSPECIFICATIONS
PHYSICALSPECIFICATIONS
NOTES
