Optimus PC2020-10PH/10G User manual

Category
Door intercom systems
Type
User manual
1 PC2020 10PH/10G 600-0124B
TECHNICAL SHEET
Professional
intercom system:
PC 2020 10PH/10G
installation programming
connection
use
GENERAL
The PC 2020 10PH/10G is an interphone master station presented in a desktop station. It allows a ten-way voice connection to
the slave stations of the Castel range as well as ten non-slaved remote door-release controls.
The hardware must be installed and used in accordance with the guidelines of this document.
Voice-transmission lines Door-release lines
10 10
TECHNICAL SPECIFICATIONS
Conformity with European standards
- Safety according to EN 60950
- EMC emissions according to EN 55022 class B
- EMC immunity according to EN 50082-1
Mechanical specifications of the consoles
- Protection rating IP40 according to EN 60529
- ABS box, wall-hanging desktop station.
- Dimensions: H 240 mm x W 297mm x T 62 mm
Mechanical specifications of the hubs
- Protection rating IP30 according to EN 60529
- ABS box, wall-mounted or desktop installation.
- Hub dimensions: L 205 mm x W 140 mm x H 65mm
General electrical properties
- Protection against electric shocks, class 1 according to EN 60950.
- Consumption with 230 V: 180mA, 40 VA;
- Operating temperature: 0 °C / +50 °C.
- Storage temperature: -20 °C / +70 °C.
Link between the console and the hub
- The 2020 console is linked to its two hubs by a 3-metre cable.
Electrical specifications of the hub
- Mains power input (230 V +/- 10%, 50 Hz).
The supplied contact is a Normally Open dry contact
Max. voltage: 15 Volts - Max. current: 1A effective
CONFIGURATION
Turn the device over and set the microswitches according to the use of each
line.
If the line is used, select "ON" for the channel (switch to "ON").
If the line (1 to 5) is connected to a slave station, select "PS" (switch to
"OFF") for this line.
If the line (1 to 5) is connected to a master station, select "PC" (switch to
"ON") for this line.
Warning: In order for the configuration to be acknowledged, you must
disconnect and reconnect the mains plug. (The configuration is only
acknowledged after switching on).
Factory settings of the voice-transmission lines and the door-release lines
1 à 5
1 à 5
Configuration
des
LIGNES
UTILISEE
NON
UTILISEE
PC
PS
ON
OFF
SW1 SW2
ON
ON
6 à 10
Configuration
des
LIGNE S
ON
OFF
SW1
S
W2
ON
ON
6 à 10
11 à 15
11 à 15
Configuration
des
LIGNES
UTILISEE
NON
UTILISEE
PC
PS
ON
OFF
SW1 SW2
ON
ON
16 à 20
Configuration
des
LIGNE S
ON
OFF
SW1
S
W2
ON
ON
16 à 20
lines 1 to 5 for voice transmission lines 6 to 10 for non-slaved door
release
Do not change this configuration
lines 11 to 15 for voice transmission lines 16 to 20 for non-slaved door
release
Do not change this configuration
or or or or or or
1 pair + screen
1 pair + screen
1 pair + screen
1 pair + screen
1 pair + screen
1 pair + screen
1 pair + screen 1 pair + screen
1 pair + screen
1 pair + screen
1 pair + screen
1 pair + screen
1 pair + screen
Hub Hub
Mains adapter Mains adapter
PS = slave station
PC = master station
3-metre cable 3-metre cable
LINE
Configuration
LINE
Configuration
LINE
Configuration
LINE
Configuration
USED
NOT
USED
USED
NOT
USED
1 to 5 1 to 5 6 to 10 6 to 10 11 to 15 11 to 15 16 to 20 16 to 20
2 PC2020 10PH/10G 600-0124B
CONNECTION & INSTALLATION
Every connection between a master station and a slave station or
between two master stations (Interco) requires a screened cable
with one twisted pair.
Maximum distance: 500 m with a cable cross-section of 0.3 mm²
(6/10
ths
) and 1000 m with a cable cross-section of 0.6 m
(9/10
ths
).
When wall-mounted, the console is hung from two screws.
The connection is made by a screw terminal block built into the
hub (max. 1 mm²).
The connection between master stations (Interco) is polarised.
Respect the link from L of the first master station to L of the
second master station and the link from L' of the first master
station to L' of the second master station. The drain wire of
the screened cables must be connected to the drain connection
terminal provided for this purpose.
Drain
Drain
Drain Drain
Connecteur pupitre
Connecteur pup itre
INTERIEUR BOITE DE RACCORDEMENT
FIXATION MURALE PUPITRE POSTE CHEF
214
Perçage pour vis de 5 maxi
Lignes 1 à 5 ou 11 à 15 Lignes 6 à 10 ou 16 à 20
L1
G1
L2
G2
L3
G3
L4
G4
L5
G5
L'1
G'1
L'2
G'2
L'3
G'3
L'4
G'4
L'5
G'5
DRAIN DRAIN
LL'
GG' GG' GG' GG' GG'
LL' LL' LL' LL'
16273849510
11 1612 1713 18
14 1915 20
J1 J2
J3 J4
Lines equipped with the door release option are identified in the hub with a label.
The supplied contact is a Normally Open (NO) dry contact
If the door-release control has power specifications above 1 A /15 Volts , a power interface will need to be used (relay).
USE
Calling from the master station
To a Slave Station (SS).
Press the selected key in order to tap the line. A pilot light shows that the line is in use. The call is then placed by pressing the
ringer key. The conversation is carried out using the Speak / Listen key (S/L). Press to speak, release to listen.
To a Master Station (Interco).
Pressing the selected key triggers the call to the called master station by a ringer pattern. A pilot light shows that the line is in use.
The line is tapped as soon as the called master station presses the key that corresponds to the call. The called master station
manages the conversation.
Calling the master station
From a Slave Station (SS).
Calling from a SS (call key pressed) triggers the transmission of a ringer pattern. The pilot light corresponding to the line flashes.
The line is tapped by pressing the corresponding key. The master station manages the conversation.
From a Master Station (Interco).
Calling from a master station triggers the transmission of a ringer pattern. The pilot light corresponding to the line flashes. The
line is tapped by pressing the corresponding key. The called master station manages the conversation.
Ending a call
Pressing the END key ends the call. In Interco links, the two master stations must each press their respective END keys.
Any other calls received during the communication will be memorised (the pilot light for the line flashes). They can then be
repeated after the end of the current communication.
Power
The voice-transmission power can be adjusted at any time for transmission and reception.
The ringer power can be adjusted by the installer (access under the console).
All Call from the MS
All Calls are made by pressing the All Call key, which taps the lines of all the slave stations, or by successively selecting several
SS lines (the pilot lights remain lit). The MS can then listen to all the SS units. The operator can transmit a ringer pattern by
pressing the ringer key. The MS broadcasts its message to all the SS units by means of the S/L key and ends the all call via the
"end" key.
The door release can be controlled remotely by pressing one of the buttons from 6 to 10 and from 16 to 20. The contact is closed
while the button is pressed.
Protect the environment
Dispose of the product in
accordance with environmental
conservation rules
CASTEL
Z.I. Saint Lambert des Levées - 49412 SAUMUR Cedex -FRANCE
www.castel.fr - Tel.: +33 2 41 40 41 40 - Fax: +33 2 41 40 41 49
Non-contractual document. The manufacturer reserves the right to make any changes it considers necessary without prior warning.
WALL MOUNTING OF THE MASTER STATION
Drill-hole for max. 5-mm screw
INSIDE OF THE HUB
Console connector Console connector
Lines 1 to 5 or 11 to 15 Lines 6 to 10 or 16 to 20
  • Page 1 1
  • Page 2 2

Optimus PC2020-10PH/10G User manual