1 PI-1BP GT - 600-0127 A
TECHNICAL SHEET
Professional
intercom system:
PI-1BP SLAVE STATION
installation programming
connection
use
GENERAL
The PI-1BP is a slave interphone station presented in a wall
plate. It allows a one-way voice connection to a Master Station
of the entire Castel range.
The anti-vandalism version of the door opener is the PI-1BP AV.
The handicapped version of the door opener is the PI-1BP H AV.
The hardware must be installed and used in accordance with
the guidelines of this document.
ATTRACTIVE
VOICE TRANSMISSION QUALITY
USER FRIENDLY
EASY INSTALLATION
EMC COMPATIBILITY
TECHNICAL SPECIFICATIONS
Conformity with European standards
- Safety rules according to EN 60950.
- EMC emissions according to EN 55022 class B.
- EMC immunity according to EN 50082-1.
Mechanical specifications of the PI-1BP
- Protection rating IP54 according to EN 60529.
- Front panel in matt satin-finished aluminium.
- Raised or flush mounting.
- Dimensions: Front panel: H 176.5 mm x W 97.5 mm
Embeddable base: H 169 mm x W 95 mm x D 45 mm
Belt: H 196 mm x W 109 mm x D 55 mm
Mechanical specifications of PI-1BP AV & PI-1BP H AV
- Protection rating IP54 according to EN 60529.
- Protection rating IK09 according to EN 50102.
- Stainless-steel front panel with no label holder, closed by two
anti-vandalism screws.
- Raised or flush mounting.
- Dimensions: identical to the PI-1B
General electrical properties
- Protection against electric shocks, class 1 according to EN
60950.
- Operating temperature: -20 °C / +50°C.
- Storage temperature: -20 °C / +70 °C.
Poste Chef
L1 L'1
PI-1B
PI-1BP H AV
1 Paire + écran
CONNECTION
The connection between the Slave Station and a Master Station
requires a screened cable with one twisted pair.
Maximum distance of the Master Station: 500 m with a cable cross-
section of 0,3mm² (6/10
ths
) and 1000m with a cable cross-section of
0,6mm² (9/10
ths
).
The connection is carried out via a 2-stud split fitting.
USE
• Calling the master station from a Slave Station
Calling a Master Station (call key pressed) triggers the transmission of a
ringing stream to the selected Master Station for as long as the key is
pressed.
• Master Station line tap
The connected Master Station can establish communication with the
Slave Station at any time. The Master Station manages the conversation.
• Power
The voice-transmission power can be adjusted on the Master Station.
PC 1 CALL KEY
1 pair + screen
Master Station