Optimus PC2010-5PH/5G User manual

Type
User manual
1 PC2010 5PH/5G 600-0123A
TECHNICAL SHEET
Professional
intercom system:
PC 2010 5PH/5G
installation programming
connection
use
GENERAL
The PC 2010 5PH/5G is an interphone master station presented in a desktop station. It allows a five-way voice connection to the
slave stations of the Castel range as well as five non-slaved remote door-release controls.
The hardware must be installed and used in accordance with the guidelines of this document.
TECHNICAL SPECIFICATIONS
The contacts for the remote door-release control are Normally Open (NO) dry contacts
Max. voltage: 15 volts
Max current: 1A effective
CONFIGURATION
The door release option is factory-set for lines 6, 7, 8, 9 and 10
line 1 to 5
SW1 = ON
SW2 = OFF
line 6 to 10
SW1 = OFF
SW2 = ON
Turn the device over and set the microswitches of the other lines according to their use as indicated in the specific technical
documentation for your product.
CONNECTION & INSTALLATION
Lines equipped with the door release option are identified in the
hub with a GG' label.
Connect the door-release controls to GG'
If the door-release control has power specifications above 1 A /15
Volts , a power interface will need to be used (relay).
USE
The remote door-release control buttons are those of lines 6 to 10 which have been equipped with the door-release option.
Pressing a remote door-release control button closes the dry contact associated with the line while the button is pressed. The
signal remains lit while the contact is closed.
The operator can activate a remote door-release control even when no lines have been previously selected.
Protect the environment
Dispose of the product in
accordance with environmental
conservation rules
CASTEL
Z.I. Saint Lambert des Levées - 49412 SAUMUR Cedex -FRANCE
www.castel.fr - Tel.: +33 2 41 40 41 40 - Fax: +33 2 41 40 41 49
Non-contractual document. The manufacturer reserves the right to make any changes it considers necessary without prior warning.
Line
configuration
USED
NOT
USED
ON
OFF
ON
OFF
Line
configuration
USED
NOT
USED
1 to 5 1 to 5 6 to 10 6 to 10
Console connector Console connector