1 PC2005 3PH/2G 600-0122A
TECHNICAL SHEET
Professional
intercom system:
PC 2005 3PH/2G
installation programming
connection
use
GENERAL
The PC 2005 3PH/2G is an interphone master station presented in a desktop station. It allows a three-way voice connection to the
slave stations of the Castel range as well as two remote door-release controls.
The hardware must be installed and used in accordance with the guidelines of this document.
TECHNICAL SPECIFICATIONS
The contacts for the remote door-release control are Normally Open (NO) dry contacts
Max. voltage: 15 volts
Max current: 1A effective
CONFIGURATION
The door release option is factory-set for lines 4 and 5
SW1 line 4 = off
SW2 line 4 = on
SW1 line 5 = off
SW2 line 5 = on
5432
ON
1 5432
ON
1
1 à 5
1 à 5
Configuration
des
LIGNES
UTILISEE
NON
UTILISEE
ON
OFF
PC
PS
A
B
A
B
SW1
SW2
Turn the device over and set the microswitches of lines 1 to 3 according to their use as indicated in the specific technical
documentation for your product.
CONNECTION & INSTALLATION
Lines equipped with the door release option are identified in the
hub with a GG' label.
Connect the door release control to GG'
If the door-release control has power specifications above 1 A /15
Volts , a power interface will need to be used (relay).
USE
The remote door-release control buttons are those of lines 4 and 5 which have been equipped with the door-release option.
Pressing a remote door-release control button closes the dry contact associated with the line while the button is pressed. The
signal remains lit while the contact is closed.
The operator can activate a remote door-release control even when no lines have been previously selected.
Protect the environment
Dispose of the product in
accordance with environmental
conservation rules
CASTEL
Z.I. Saint Lambert des Levées - 49412 SAUMUR Cedex -FRANCE
www.castel.fr - Tel.: +33 2 41 40 41 40 - Fax: +33 2 41 40 41 49
Non-contractual document. The manufacturer reserves the right to make any changes it considers necessary without prior warning.