Focal Point Seem 2 LED Asymmetric Recessed FSM2AL Installation guide

Type
Installation guide
IS0650 REV. C ©2019 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference 1 of 3
Seem® 2 LED Asymmetric
FSM2AL | Grid Ceiling
Luminaires must be installed by a qualied
electrician (check with local and national
codes for proper installation).
To prevent electrical shock, disconnect
electrical supply before installation or
servicing.
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
xture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC.
Any reproduction in part or whole without
the written permission of Focal Point, LLC
is prohibited.
POWER OFF
POWER ON
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
BEFORE YOU BEGIN
PARTS LIST
FOCAL POINT
INSTRUCTION KEY
SHIPPED IN HARDWARE BAG SHIPPED INSTALLED
Lens Tool
(A09240)
(Axed To Housing.
One Per Run)
Reector Screw (72010)
(8-18 X 1/4 Self Tapping Screw)
U - Individual Unit
S - Start of Run
I - Intermediate
E - End Of Run
CONFIGURATIONS ARE
RUN SPECIFIC, CONSULT
FACTORY DRAWINGS BEFORE
BEGINNING INSTALLATION.
GRID SPACING
FOR ALL GRID TYPES
3.50"
88.9 mm
Joiner Bracket Assembly
(A11623-01)
Tie-Wire
Bracket
(12547)
Tie-Wire
Bracket Screw (72010)
(8-18 X 1/4 Self Tapping Screw) Lens End Piece
(A08608)
(72010)
Joiner Pin
(70058)
IS0650 REV. C ©2019 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference 2 of 3
4
7
3
2
11
1
511
6
RAIL & CLIP GUIDE
CHECK RAIL & CLIP POSITIONS BEFORE INSTALLATION. ARROWS INDICATE SCREW POSITIONS.
TO CHANGE IN THE FIELD REMOVE AND REINSTALL ACCORDING TO DIAGRAMS BELOW.
G1: Std 15/16" Lay-In Tile
G2: Std 9/16" Lay-In Tile
STD = 1-1/2" TEE HEIGHT, TALL = 1-11/16" TEE HEIGHT
G4: Tall 15/16" Lay-In Tile
G5: Tall 9/16" Lay-In Tile
G3: 9/16" Slot-Tee Tegular Tile
T1: Std 15/16" Tegular Tile
T2: Std 9/16" Tegular Tile
T6: 9/16" Node Tegular Tile
T4: Tall 15/16" Tegular Tile
T5: Tall 9/16” Tegular Tile
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
MAKE ELECTRICAL CONNECTIONS
INDIVIDUAL UNITS: STEPS 1, 3, & 7
8
MAKE ELECTRICAL CONNECTIONS
9a
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
SECURE REFLECTOR TO HOUSING
(4 SCREWS PER REFLECTOR)
IS0650 REV. C ©2019 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference 3 of 3
3
11
9c 10
11
11
111
2
REFERENCE INSTRUCTIONS ON INCLUDED
TOOL FOR LENS INSTALLATION.
DRIVER SERVICE
EMERGENCY
SEE BATTERY MANUFACTURER
INSTRUCTIONS
EMERGENCY MAXIMUM
MOUNTING HEIGHT:
19.08'
ADJUST IF NEEDED
9b
  • Page 1 1
  • Page 2 2
  • Page 3 3

Focal Point Seem 2 LED Asymmetric Recessed FSM2AL Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI