Focal Point Seem 6 Pop-Down Lens Recessed FSM6L-PD Installation guide

Type
Installation guide
©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
1 of 4
IS0566 REV. G
Seem® 6 LED
Grid Ceiling | FSM6L
Luminaires must be installed by a qualified
electrician (check with local and national
codes for proper installation).
To prevent electrical shock, disconnect
electrical supply before installation or
servicing.
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
fixture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC. Any
reproduction in part or whole without the
written permission of Focal Point, LLC is
prohibited.
POWER OFF
POWER ON
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
BEFORE YOU BEGIN COMPONENT KEY
INSTRUCTION KEY Joiner Bulkhead
(A15570-01)
Joiner
Bracket
(A15328-01)
Tie-Wire
Bracket
(12547)
Lens End Piece
(A12498)
Lens Tool (A15966-01)
(Aixed to housing.
One per run)
Joiner Bracket-
Screw
(72009)
Tie-Wire
Bracket Screw
(72010)
(8-18 x 1/4 Self
tapping screw)
9/16
grid
15/16
grid
6.00"
152.4mm
6.375"
161.9mm
9/16
grid
15/16
grid
6.00"
152.4mm
6.375"
161.9mm
RAIL & CLIP GUIDE
CHECK RAIL & CLIP POSITIONS BEFORE INSTALLATION. ARROWS INDICATE SCREW POSITIONS.
TO CHANGE IN THE FIELD REMOVE AND REINSTALL ACCORDING TO DIAGRAMS BELOW.
G: STD /" LAYIN TILE
G: STD /" LAYIN TILE
STD = /" TEE HEIGHT, TALL = /" TEE HEIGHT
G: TALL /" LAYIN TILE
G: TALL /" LAYIN TILE
G: /" SLOTTEE TEGULAR TILE
T: STD /" TEGULAR TILE
T: STD /" TEGULAR TILE
T: /" NODE TEGULAR TILE
T: TALL /" TEGULAR TILE
T: TALL /” TEGULAR TILE
FOCAL POINT
U - Individual
S - Start of Run
I - Intermediate
E - End of Run
TEE SPACING
Reflector Screw
(72010)
Joiner Bulkhead Screw
(72010)
Corner Unit
INCLUDED HARDWARE
Drop Lens
(indivudual housings
only up to 8’)
Flush Lens
PARTS SHIPPED INSTALLED
2 of 4
IS0566 REV. G ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
2
6
811
9
3
1111
7X
CORNER UNIT MUST BE
ASSEMBLED PRIOR TO
CEILING INSTALLATION.
1
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
5
4
MAKE ELECTRICAL CONNECTION
individual installations
skip to step 9
3 of 4
IS0566 REV. G ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
11 SECURE REFLECTORS
TO HOUSING
 SCREWS PER REFLECTOR
3
1
11
DRIVER SERVICE
11
12
AVOID ALL CONTACT
WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
11
13
REFERENCE INSTRUCTIONS ON INCLUDED
TOOL FOR LENS INSTALLATION.
10
2
11
13
DROP LENS
FLUSH LENS
FLUSH LENS
MAKE ELECTRICAL CONNECTION
EMERGENCY
SEE BATTERY MANUFACTURER
INSTRUCTIONS
emergency battery
maximum mounting height: 18.00'
emergency circuit
maximum mounting height: 21.00'
4 of 4
IS0566 REV. G ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
ACUITY nLIGHT
1
123
5
4
CONNECT
CAT CABLE
BY OTHERS
CAT CABLE
BY OTHERS
WATTSTOPPER
HUBBELL NX
1
CONNECT
CAT CABLE
BY OTHERS
CONNECT
CAT CABLE
BY OTHERS
  • Page 1 1