Focal Point Seem 1 Pop-Down Lens Recessed FSM1-PD, Seem 1 Recessed FSM1 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Focal Point Seem 1 Pop-Down Lens Recessed FSM1-PD Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
IS0690 REV. H 2022 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 2
Seem 1 grid ceiling
FSM1
focal point
U -
individUal
S -
Start of rUn
i -
intermediate
e -
end of rUn
key
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
power off
power on
attention
2.5"
63.5 mm
2.125"
53.9 mm
grid Spacing
configUrationS are rUn Specific, pleaSe conSUlt factory drawingS before beginning inStallation.
partS Shipped inStalled
inclUded hardware
partS liStS
corner Unit
pop-down lenS
(individUal hoUSingS
only Up to 8’)
flUSh lenS
joiner Screw
(72074)
joiner waSher
(700158)
linear joiner
bracket
(a37621-01)
reflector Screw
(72026)
(#6x1/4 Self tapping
Screw)
rail & clip gUide
check rail & clip poSitionS before inStallation. arrowS indicate Screw poSitionS.
to change in the field remove and reinStall according to diagramS below.
Std = 1-1/2" tee height, tall = 1-11/16" tee height
g1: Std 15/16" lay-in tile
g2: Std 9/16" lay-in tile
g3: 9/16” Slot-tee tegUlar tile
t1: Std 15/16” tegUlar tile
t2: Std 9/16” tegUlar tile
t6: 9/16” node tegUlar tile
g4: tall 15/16" lay-in tile
g5: tall 9/16" lay-in tile
t4: tall 15/16” tegUlar tile
t5: tall 9/16” tegUlar tile
corner joiner
bracket 1
(a39928-03)
corner joiner
bracket 2
(a37621-02)
prodUct id location
prodUct
id
label
on
reflector
9/16" grid 15/16" grid
Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls
and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0690 REV. H 2022 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 2
1
46
2
11115
make electrical connectionS
individUal inStallationS
Skip to Step 6
3
2
1
driver ServiceaSymmetric lenS detail
DO NOT
OVER-TIGHTEN
SECURE TO
STRUCTURE ABOVE
SECURE TO
STRUCTURE ABOVE
CORNER ASSEMBLY
B C
corner
Unit
mUSt
be
joined
to
one
of
the
linear
UnitS
prior
to
ceiling
inStallation
AREMOVE AND DISCARD JOINER
BRACKET FROM LINEAR UNIT
WHEN JOINING TO CORNER
ASYMMETRIC LENS
DISTRIBUTION DIRECTION
/