The Savant SmartLighting LMD/LMR/LMC modules should be installed in Savant’s two-module
enclosure (ENC-2000) or four-module enclosure (ENC-4000). Savant control modules and
enclosures are necessary components for a Savant SmartLighting system. This guide provides
general information for all dimmer, relay and control modules.
Specifications
32° to 95° F (0° to 35° C) - Ambient Operating
10% to 80% Relative Humidity (non-condensing)
Over 98% at full rated load
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specifications.
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specifications.
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specifications.
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specifications.
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specifications.
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specifications.
The image below shows a High Power Relay Module - 120 volt (LMR-8120) and an 8-Channel
Dimmer Module - 120 volt (LMD-8120).
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Four Module Enclosure
Low Voltage Side
Line Voltage Side
Barrier
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
LABELING LOADS
ON OUTPUTS
ROTARY
ADDRESS
SWITCHES
MS
(Address
shown
is
23)
LS
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL 1
LINE 1
LOAD 1
LINE 2
LOAD 2
LINE 3
LOAD 3
LINE 4
LOAD 4
LINE 5
LOAD 5
LINE 6
LOAD 6
LINE 7
LOAD 7
LINE 8
LOAD 8
SERIAL NO.
12345678
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
R
Dimmer
R
Relay
A. Install modules in their proper location in each enclosure as specified on the enclosure schedule.
B. Modules mount in enclosures by inserting metal screws (provided) through tabs on the module can and tightening to the back panel of
the enclosure.
C. Set module address (per enclosure schedule) with the two alpha-numeric rotary address switches located on the left hand side of each
module.
MS stands for Most Significant Digit, LS means Least Significant Digit. Modules used with a Standard or Compact CCU are limited to
numeric address only. Modules used with the FIVEk CCU can use both alpha and numeric addresses.
D. Write the drawing load number (as per the enclosure schedule) on the module label to the side of each load. These numbers will
correspond to the numbers previously labeled on your load homeruns.
E. Install all modules prior to line voltage connections.
A. Make line voltage connections, matching load number label on wire to the proper output on the proper module according to the
enclosure schedule. (See the Installation and Troubleshooting Manual for detailed drawings and instructions.)
Caution! Before
wiring to modules, check for shorts by applying power to loads. There is a barrier in the enclosure to isolate line
voltage from low-voltage. Do not cross over or through this barrier with wires. Keep low voltage wires on the low-voltage side and line
voltage wires on the line-voltage side.
Note: Each channel has a manual override switch to turn on and off connected loads. This switch can be used to turn lights on prior to
installation of the CCU or keypads.
EQUIPMENT
INSTALLATION
STEP 3.
CONTROL MODULE INSTALLATION
STEP 4.
LINE VOLTAGE CONNECTIONS
4
The Savant SmartLighting High Power Relay Module is available in two models: LMR-8120 for
120 volts and LMR-8240 for 240 volts. This Quick Reference Guide provides information for both
models of the High Power Relay module.
Box Contents
(1) High Power Relay Module 120V (LMR-8120-xx)
or
(1) High Power Relay Module 240V (LMR-8240-xx)
(1) Quick Reference Guide (this document)
System Components
Two-module Enclosure (ENC-2000-xx)
Four-module Enclosure (ENC-4000-xx)
SmartLighting Keypad Links (SKL-1000/SKL-4000)
SmartLighting Controllers (SSL-P002/SSL-P018)
Enclosure Diagnostic Bus Monitor (ENC-BM01-xx)
Enclosure Voltage Divider (ENC-VDIV-xx)
Enclosure Ground Bar (ENC-GBAR-xx)
Enclosure Neutral Bar (ENC-NBAR-xx)
Enclosure Transorb Board (ENC-trans-xx)
Enclosure 120V Load Resister (ENC-LR120-xx)
Enclosure 240V Load Resister (ENC-LR240-xx)
Specifications for LMR-8120
EnvironmentalEnvironmental
Temperature 32° to 95° F (0° to 35° C) - Ambient Operating
Humidity 10% to 80% Relative Humidity (non-condensing)
Efficiency Over 98% at full rated load
Maximum Thermal Dissipation 7 watts (24 BTU/hour)
Dimensions and WeightDimensions and Weight
Height 7.63 in/19.38 cm
Width 10.25 in/26.04 com
Depth 3.0 in/7.62 cm
Weight 1.46 lb/0.66 kg
PowerPower
Operating Power 120V AC, 6 watts
Supply Voltage 120V AC, 50/60Hz
Field Serviceable Fuse 250 mA/250V AC
Module Rating 120 amps (2400 watts de-rated to 1920 watts)
Output Rating 20 amps Motor: 1/2 hp
ComplianceCompliance
Safety and Emissions FCC Part 15
RoHS Compliant
High Power Relay Module 120 Volt - LMR-8120
Specifications for LMR-8240
EnvironmentalEnvironmental
Temperature 32° to 95° F (0° to 35° C) - Ambient Operating
Humidity 10% to 80% Relative Humidity (non-condensing)
Efficiency Over 98% at full rated load
Maximum Thermal Dissipation 7 watts (24 BTU/hour)
Dimensions and WeightDimensions and Weight
Height 7.63 in/19.38 cm
Width 10.25 in/26.04 com
Depth 3.0 in/7.62 cm
Weight 1.26 lb/0.57 kg
PowerPower
Operating Power 240 AC, 2 watts
Supply Voltage 240 AC, 50/60Hz
Field Serviceable Fuse 250 mA/250V AC
Module Rating 120 amps (4800 watts de-rated to 3840 watts)
Output Rating 20 amps Motor: 1/2 hp
ComplianceCompliance
Safety and Emissions FCC-Part 15 | CE Mark
RoHS Compliant
High Power Relay Module 240 Volt - LMR-8240
High Power Relay Module
(LMR-8120/LMR-8240)
Quick Reference Guide
009-0754-00
LMR-8120-00
LMR-8240-00
Copyright © 2012 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners.
Savant Systems, LLC reserves the right to change product specifications without notice.
100112
The Savant SmartLighting 8-Channel Dimmer Module is available in two models: LMD-8120 for
120 volts and LMD-8240 for 240 volts. This Quick Reference Guide provides information for both
models of the 8-Channel Dimmer module.
Box Contents
(1) 8-Channel Dimmer Module 120V (LMD-8120-xx)
or
(1) 8-Channel Dimmer Module 240V (LMD-8240-xx)
(1) Quick Reference Guide (this document)
System Components
Two-module Enclosure (ENC-2000-xx)
Four-module Enclosure (ENC-4000-xx)
SmartLighting Keypad Links (SKL-1000/SKL-4000)
SmartLighting Controllers (SSL-P002/SSL-P018)
Enclosure Diagnostic Bus Monitor (ENC-BM01-xx)
Enclosure Voltage Divider (ENC-VDIV-xx)
Enclosure Ground Bar (ENC-GBAR-xx)
Enclosure Neutral Bar (ENC-NBAR-xx)
Enclosure Transorb Board (ENC-trans-xx)
Enclosure 120V Load Resister (ENC-LR120-xx)
Enclosure 240V Load Resister (ENC-LR240-xx)
Specifications for LMD-8120
EnvironmentalEnvironmental
Temperature 32° to 95° F (0° to 35° C) - Ambient Operating
Humidity 10% to 80% Relative Humidity (non-condensing)
Efficiency Over 98% at full rated load
Maximum Thermal Dissipation 25 watts (84 BTU/hour)
Dimensions and WeightDimensions and Weight
Height 7.63 in/19.38 cm
Width 10.25 in/26.04 com
Depth 3.0 in/7.62 cm
Weight 1.34 lb/0.60 kg
PowerPower
Operating Power 120V AC, 3 watts
Supply Voltage 120V AC, 50/60Hz
Module Rating 20 amps (2400 watts de-rated to 1920 watts)
Output Rating 15 amps (1800 watts) max per output
ComplianceCompliance
Safety and Emissions FCC Part 15 | ETL
RoHS Compliant
8-Channel Dimmer Module - LMD-8120
Specifications for LMD-8240
EnvironmentalEnvironmental
Temperature 32° to 95° F (0° to 35° C) - Ambient Operating
Humidity 10% to 80% Relative Humidity (non-condensing)
Efficiency Over 98% at full rated load
Maximum Thermal Dissipation 40 watts (135 BTU/hour)
Dimensions and WeightDimensions and Weight
Height 7.63 in/19.38 cm
Width 10.25 in/26.04 com
Depth 3.0 in/7.62 cm
Weight 1.78 lb/0.80 kg
PowerPower
Operating Power 240 AC, 2 watts
Supply Voltage 240 AC, 50/60Hz
Module Rating 20 amps (4800 watts de-rated to 3840 watts)
Output Rating 15 amps (3600 watts) max per output
ComplianceCompliance
Safety and Emissions FCC-Part 15 | ETL | CE Mark
RoHS Compliant
8-Channel Dimmer Module - LMD-8240
8-Channel Dimmer Module
(LMD-8120/LMD-8240)
Quick Reference Guide
009-0746-00
LMD-8120-00
LMD-8240-00
Copyright © 2012 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners.
Savant Systems, LLC reserves the right to change product specifications without notice.
100112
Four Module Enclosure (ENC-4000)
NOTE: Some modules required two addresses.
Module Installation
Install modules in the proper location within each enclosure as specified on the enclosure
schedule generated by LiteWare
®
, Savant's Lighting Control design and programming software.
CAUTION: Before removing or installing any of the modules, remove power from the
Savant SmartLighting System.Failure to do so will result in damage to the
equipment.
1. Mount modules in enclosures by inserting metal screws (provided) through the tabs on the
module can.
2. Tighten each module to the back panel of the enclosure.
3. Set the module address (per Enclosure Schedule) with the two alphanumeric rotary address
switches located on the left side of the each module (See previous figure).
MS represents the Most Significant Digit.
LS represents the Least Significant Digit.
4. Write the drawing load number (per Enclosure Schedule) on the module label (See previous
figure). These numbers will correspond to the numbers previously labeled on the load
homeruns.
5. When wiring the 20 amp circuit breaker to the dimmer and relay modules, follow national
electrical codes. Use at least a #12 wire and provide separate neutrals for each breaker
feed.
6. Install all modules prior to line voltage connections.
Modules
Quad II Dimmer Module - 120 volt
Quad II Dimmer Module - 240 volt
8-Channel Dimmer Module - 120 volt
8-Channel Dimmer Module - 240 volt
Dual 20 Amp Dimmer Module - 120 volt
Inverse Phase Dimmer Module - 120 volt
Electronic Dimmer Module (0-10V DC) - 120 volts
High Power Relay Module - 120 volts
High Power Relay Module - 240 volts
Fan Speed Control Module - 120 volts
Quad II Dimmer Modules: LMD-4120 and LMD-4240
1. The Quad II modules require separate line and neutral connections. The 064-8000-066
jumper cable must remain connected between both halves.
2. The Quad II modules consume two module addresses.
3. The Quad II modules provide up to 15 Amps per output with up to two 20 Amp feeds. The
Quad II Dimmer Module is compatible with AFCI breakers.
SmartLighting
LMD/LMR/LMC Modules
Quick Reference Guide
011013
Copyright © 2013 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners.
Savant Systems, LLC reserves the right to change product specifications without notice.