Savant LMI-REL2-00 Reference guide

Type
Reference guide

This manual is also suitable for

The Savant SmartLighting LMI Modules are used in the Module Enclosures for either 2-modules
(ENC-2000) or four modules (ENC-4000). These modules and module enclosures are necessary
components for the Savant SmartLighting System. This guide provides general information for
all data input modules.
Specifications
Environmental
Environmental
Temperature
32° to 95° F (0° to 35° C) - Ambient Operating
Humidity
10% to 80% Relative Humidity (non-condensing)
Efficiency
Over 98% at full rated load
Dimensions
Dimensions
Height
7.63 in/19.38 cm
Width
10.25 in/26.04 com
Depth
3.0 in/7.62 cm
Power
Power
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specificatons.
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specificatons.
Wiring
Wiring
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specificatons.
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specificatons.
Compliance
Compliance
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specificatons.
Refer to the Savant SmartLighting Deployment Guide (009-0766-00) for module
specificatons.
The image below is a Dual Momentary Contact Input Module (LMI-MOM2) .
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Four Module Enclosure
Low Voltage Side
Line Voltage Side
Barrier
NEUTRAL
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
LABELING LOADS
ON OUTPUTS
ROTARY
ADDRESS
SWITCHES
MS
(Address
shown
is
23)
LS
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NEUTRAL 1
LINE 1
LOAD 1
LINE 2
LOAD 2
LINE 3
LOAD 3
LINE 4
LOAD 4
LINE 5
LOAD 5
LINE 6
LOAD 6
LINE 7
LOAD 7
LINE 8
LOAD 8
SERIAL NO.
12345678
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
R
Dimmer
R
Relay
A. Install modules in their proper location in each enclosure as specified on the enclosure schedule.
B. Modules mount in enclosures by inserting metal screws (provided) through tabs on the module can and tightening to the back panel of
the enclosure.
C. Set module address (per enclosure schedule) with the two alpha-numeric rotary address switches located on the left hand side of each
module.
MS stands for Most Significant Digit, LS means Least Significant Digit. Modules used with a Standard or Compact CCU are limited to
numeric address only. Modules used with the FIVEk CCU can use both alpha and numeric addresses.
D. Write the drawing load number (as per the enclosure schedule) on the module label to the side of each load. These numbers will
correspond to the numbers previously labeled on your load homeruns.
E. Install all modules prior to line voltage connections.
A. Make line voltage connections, matching load number label on wire to the proper output on the proper module according to the
enclosure schedule. (See the Installation and Troubleshooting Manual for detailed drawings and instructions.)
Caution! Before
wiring to modules, check for shorts by applying power to loads. There is a barrier in the enclosure to isolate line
voltage from low-voltage. Do not cross over or through this barrier with wires. Keep low voltage wires on the low-voltage side and line
voltage wires on the line-voltage side.
Note: Each channel has a manual override switch to turn on and off connected loads. This switch can be used to turn lights on prior to
installation of the CCU or keypads.
EQUIPMENT
INSTALLATION
STEP 3.
CONTROL MODULE INSTALLATION
STEP 4.
LINE VOLTAGE CONNECTIONS
4
NOTE: Some modules required two addresses.
Module Installation
Install modules in the proper location in each enclosure as specified on the enclosure schedule.
CAUTION: Before removing or installing any of the modules, remove power from the
Savant SmartLighting System.Failure to do so will result in damage to the equipment.
1. Mount modules in enclosures by inserting metal screws (provided) through the tabs on the
module can.
2. Tighten each module to the back panel of the enclosure.
3. Set the module address (per Enclosure Schedule) with the two alpha-numeric rotary
address switches located on the left side of the each module (See figure above.).
MS represents for Most Significant Digit.
LS represents the Least Significant Digit.
Modules
Part Number
Model Name
LMI-REL2
Dual Low Voltage Relay Module
LMI-MOM2
Dual Momentary Contact Input Module
LMI-MAI2
Dual Maintained Contact Input Module
SmartLighting
LMI Modules
Quick Reference Guide
009-0755-00
Copyright © 2012 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners.
Savant Systems, LLC reserves the right to change product specifications without notice.
100512
  • Page 1 1

Savant LMI-REL2-00 Reference guide

Type
Reference guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI