11 Part No. 5030985
Revision 0
Carbonator Tank Purge Tube Routing Instructions for SV200/250 Units
Routing Instructions
1. During installation of unit, the carbonator
tank purge tube (A) must be properly routed
to a drain. Once the splash panel has been
removed from unit, remove the coiled tubing
from behind insulated tube holding
carbonator tank purge tube (See Figure 1).
2. Route carbonator tank purge tube (A) down
front of unit and behind drain pan (See
Figure 2). Be sure not to collapse or kink
carbonator tank purge tube during routing
from unit to drain.
3. The carbonator tank purge tube (A) can be
routed down through the counter top that unit
has been installed on or out the rear of unit.
Then install carbonator tank purge tube to a
drain (See Figure 3). Follow all local and
national plumbing codes when routing
carbonator tank purge tube to the drain.
Figure 1
Figure 2
Drain
Pan
Figure 3
Purge tube is connected to
the pressure relief valve on
carbonator tank and must
be routed to a drain