MULTIPLEX MD Purge Tube Routing Installation guide

Type
Installation guide
11 Part No. 5030478
Revision 0
Carbonator Tank Purge Tube Routing Instructions for MD Series Units
Routing Instructions
1. During installation of unit the carbonator
tank purge tube (A) must be properly routed
to a drain. Once the splash panel has been
removed from unit remove twist tie (B) that
holds carbonator tank purge tube (See Figure
1).
2. Route carbonator tank purge tube (A) down
front of unit and behind drain pan (See
Figure 2). Be sure not to collapse or kink
carbonator tank purge tube during routing
from unit to drain.
3. The carbonator tank purge tube (A) can be
routed down through the counter top that unit
has been installed on or out the rear of unit.
Then install carbonator tank purge tube to a
drain (See Figure 3). Follow all local and
national plumbing codes when routing
carbonator tank purge tube to the drain.
Figure 1
B
A
Figure 2
A
Drain
Pan
A
Figure 3
To
Drai
n
Rear of Unit
Pressure Relief Valve
Purge tube is connected to
the pressure relief valve on
carbonator tank and must
be routed to a drain