Sabroe Mounting of CX-17 coupling Installation guide

  • Hello! I've reviewed the mounting instruction document for the CX-17 coupling. This document provides detailed guidance on mounting, including lubrication and tightening procedures. I'm ready to answer any questions you might have about the installation process.
  • What is the required distance between the journals?
    How should the journals be prepared for mounting?
    What is the mounting distance for the compressor hub from the motor shaft?
    What torque should the compressor hub screws be tightened to?
    What is the torque to tighten screws when assembling the rubber part and flange?
    What is the torque to tighten screws when assembling the intermediate part and the rubber part?
Page 1 of 4
Johnson Controls Denmark ApS
Christian X's Vej 201 ∙ 8270 Højbjerg ∙ Denmark
Phone +45 87 36 70 00 ∙ Fax +45 87 36 70 05 ∙ www.sabroe.com
CVR No 19 05 61 71
Mounting instruction
0005616
10 January 2017
Mounting of CX-17 coupling
1. Check that the distance between the journals is 200 mm (+8/-0 mm) Adjust, if necessary.
2. Lubricate the journals with thin oil.
3. Mount the compressor hub and locking assembly with a distance of 208 mm from the motor shaft.
Tighten crosswise to 83 Nm.
4. Position the motor hub loosely on the motor shaft.
Page 2 of 4
Johnson Controls Denmark ApS
Christian X's Vej 201 ∙ 8270 Højbjerg ∙ Denmark
Phone +45 87 36 70 00 ∙ Fax +45 87 36 70 05 ∙ www.sabroe.com
CVR No 19 05 61 71
5. Lubricate all mounting surfaces with thin oil and all bolt heads with copper grease.
6. Assemble the rubber part and flange using 12 low-head cylindrical screws (M10 x 16 mm).
7. Tighten crosswise to 60 Nm.
Page 3 of 4
Johnson Controls Denmark ApS
Christian X's Vej 201 ∙ 8270 Højbjerg ∙ Denmark
Phone +45 87 36 70 00 ∙ Fax +45 87 36 70 05 ∙ www.sabroe.com
CVR No 19 05 61 71
8. Assemble the intermediate part and the rubber part using 12 M10 x 25 mm screws.
Tighten crosswise to 60 Nm.
Page 4 of 4
Johnson Controls Denmark ApS
Christian X's Vej 201 ∙ 8270 Højbjerg ∙ Denmark
Phone +45 87 36 70 00 ∙ Fax +45 87 36 70 05 ∙ www.sabroe.com
CVR No 19 05 61 71
9. Push in all three parts between the hubs.
10. Attach the flange to the compressor hub using 8 M10 x 30 mm screws.
Tighten crosswise to 68 Nm.
11. Attach the intermediate part to the motor hub using 3 countersunk M16 x 40 screws.
12. Lubricate the countersunk heads with copper grease, and tighten to 150 Nm.
13. Attach the motor hub with the 2 mounting screws by tightening them a little at a time to 83 Nm.
14. Finally, tighten the pointed screw, which secures the key on the motor shaft, to 30 Nm.
Erhardt Nielsen
Manager, Compressor Development
Engineering, Sabroe Products
Industrial Refrigeration Europe
Tel: +45 87 36 77 20
Mob: +45 29 22 77 20
Internet: http://www.johnsoncontrols.dk/
/