Mounting instruction 04 October 2016
012013
Mounting of CentaMax 400-800 coupling
1. Check that the distance between the journals is 200 mm (+5/-0 mm) Adjust, if necessary.
2. Lubricate the journals with thin oil. Position the motor hub loosely on the motor shaft.
3. Mount the compressor hub and locking assembly approx. 2 mm from the edge of the shaft.
4. Tighten crosswise to 83 Nm.
5. Assemble the rubber part and the intermediate part using cylindrical screws.
CentaMax 400: 16 M8 x 25 mm; tighten crosswise to 36 Nm.
CentaMax 800: 16 M10 x 25 mm; tighten crosswise to 68 Nm.
6. Insert the aluminium ring over the rubber part, and push in all three parts between the hubs.
Johnson Controls Denmark ApS
Christian X's Vej 201 ∙ 8270 Højbjerg ∙ Denmark
Phone +45 87 36 70 00 ∙ Fax +45 87 36 70 05 ∙ www.sabroe.com
CVR No 19 05 61 71
Page 1 of 3