Workrite Sierra HX 2-Leg Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Workrite Sierra HX 2-Leg Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 1 of 10
Rectangles Width Depth
24" Feet 72–90" 23–24"
30" Feet 72–90" 29–30"
Parts Included
0.4126"
#3 Drive
0.134"3/4"
0.216"
#12 Screw Size
or
O Rear Bracket
Qty: 4
P Connector Bracket
Qty: 2
A Leg
Qty: 2
D 4 mm Allen Wrench
Qty: 1
M Leg Cable, 1
meter
Qty: 2
N Power Cord
Qty: 1
J Cable Spool
Qty: 2
L " Cable Loops
Qty: 10
H Control Box
Qty: 1
G Foot Glide
Qty: 4
B Le End Bracket
Qty: 1
C Right End Bracket
Qty: 1
E #M6 × 14 mm Flat Head Cap
Screw
Qty: 28
K #8 × ⅝" Pan Head Screw
Qty: 12
F #12 × ¾" Pan Head Screw
Qty: 54
I #12 × 2" Flat Head Screw
Qty: 2
Q Style or Flat Foot Kit
Qty: 1
Tools Required:Worksurface Required, Sold Separately:
Cordless Drill #2 Phillips Bit
Screwdriver or
Driver/Drill
⅛" pilot drill bit
pencil
332" pilot drill bit
#3 Phillips Bit
Screwdriver or
Driver/Drill
Assembly & Installation Instructions:
Sierra HX 2-Leg Work Center
SEHX78-90-XXX-XX-X
or
R Standard, Bluetooth, or
Programmable Switch
Qty: 1
Need Box numbers ONLY
2 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
SAVE THESE INSTRUCTIONS
WARNING: Maximum equipment loading of table assembly in addition to specied top is as follows:
Maximum Top Weight: 83 lb (37.7 kg)
Maximum Equipment Load: 225 lb (102.2 kg)
Loading should be evenly distributed over table surfaces.
V = 120 VAC, 60 Hz / 4 A maximum
FLAMMABILITY: All worksurfaces used must meet UL 962 ammability requirements
Flame Spread Rating maximum 200
Smoke Developed Index maximum 450
WORKSURFACE MATERIAL: This frameset is designed to accommodate worksurfaces made from Industrial Particle Board with nominal thickness
of 1.125". If the worksurface is not appropriate or not mounted correctly to the table, it could cause the complete table to be unstable, it may collapse,
and for an adjustable table, the electrical components may fail.
Intended for indoor use only.
For commercial use only.
IMPORTANT SAFETY INSTRUCTIONS:
When using an electrical furnishing, basic precautions should always be followed, including the following:
Read all instructions before using this Sierra HX Work Center.
DANGER: To reduce the risk of electric shock, always unplug this Sierra HX Work Center from the electrical outlet before cleaning or servicing.
WARNING: To reduce the risk of burns, re, electric shock, or injury to persons:
1. Unplug from outlet before putting on or taking off parts.
2. Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.
3. Use this Sierra HX Work Center only for its intended use as described in these instructions, do not use attachments not
recommended by the manufacturer.
4. Never operate this Sierra HX Work Center if it has a damaged cord or plug, is not working properly, has been dropped or
damaged, or dropped into water. Return the furnishing to a service center for examination and repair.
5. Keep the cord away from heated surfaces.
6. Do not operate outdoors.
7. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
8. To disconnect, remove plug from outlet.
9. Do not exceed maximum load recommendations.
Polarized Plug Instructions (Only applicable to products having a polarized plug power cord):
Some products include a polarized plug—see Figure A (One A/C plug blade wider than the other)—to reduce the risk of
electrical shock. A polarized plug only ts a polarized power outlet one way. If the polarized plug does not t properly into the
electrical outlet turn the power plug over to see if it then ts properly and fully into the outlet. If the plug does still does not t
the outlet, contact a certied electrician to install the correct matching polarized electrical outlet.
Caution: Never modify the power cord plug in any way
Double-Insulated Products Instructions:
Some products are double-insulated. No means of grounding is required or provided on a double-insulated product; nor is a
means for grounding to be added to the product. The plug in a double insulated system is shown in Figure A. Double-insulated
products are indicated with markings of “double-insulated” or the “double box symbol” or both.
Grounding Instructions (For grounded electric products only):
Products with grounded power cords are for use on a nominal 120 V circuit and has a grounded plug as shown in Figure B
Make sure the product is connected to an electrical outlet having the same conguration as the plug shown in Figure C.
Caution: Never modify, remove, or use adaptors that eliminate the ground connections from the grounded power cord
A/C Power:
Products sold in North America and other regions are 120 V A/C as marked on the power supply/control box of the furnishing
and are to be used on a normal 120 V A/C circuit. Always follow the instructions above for power connection using grounded or
double insulated power cords as supplied.
Only use power cord(s) supplied with your electric product
Never modify, alter, use an adaptor, or change the electrical system of this product in any way.
Warning: Doing so may cause risk of electrical shock or re
Illustration Disclaimer—Power Plug and Receptacle Images:
In some cases, the images in this instruction may not match the power cord supplied with your electrical furnishing based on your region.
Plug type, blade size, and shape may change.
Grounding Pin
Figure B
Grounded Outlet
Figure C
Polarized Plug
Figure A
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 3 of 10
1 Assemble Rear Brackets Set
Assemble two sets of Rear Brackets (O) to Connector Bracket
(P) using #M6 × 14 mm Flat Head Cap Screws (E).
Use this guide to determine the correct holes for
mounting based on the width of your work center.
Tighten securely.
80"
74"
68"
E
E
E
D
O
O
O
O
O
O
P
P
P
To avoid stripping the threads, always
insert and make the first few turns
of the screw BY HAND with an Allen
wrench (D), ensuring it is in straight.
76" Work centers
88" Work centers
82" Work centers
Note!
Only use the #M6 × 14 mm Flat Head
Cap Screw (E) for assembly.
Note: Workrite Brackets can be
sized in 3" increments for any
non-Workrite top. Keep bracket
construction as symmetrical as
possible for best support.
Hardware at actual size
E #M6 × 14 mm Flat
Head Cap Screw
4 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
2 Attach Brackets to Legs
2.1 Attach Front Bracket Assembly using four (4) #M6 × 14 mm Flat Head Cap Screws (E) to both legs.
2.2 Attach Le End Bracket (B) and Right End Bracket (C) to sides of the Leg (A) using two (2) #M6 × 14 mm Flat Head
Cap Screws (E) in each bracket.
2.3 Attach Rear Bracket Assembly to sides of the Leg (A) using four (4) #M6 × 14 mm Flat Head Cap Screws (E).
Note: The Right End Bracket
will be on your le and vice
versa when the assembly is
seen upside down.
Tighten securely.
C
B
E
E
E
E
E
E
To avoid stripping the threads, always
insert and make the first few turns
of the screw BY HAND with an Allen
wrench (D), ensuring it is in straight.
Le Leg
Right Leg
Right End Bracket
Le End Bracket
front
Front & Rear Bracket Assembly
O& P
2.1
2.1
2.3
2.3
2.2
2.2
A
A
D
E #M6 × 14 mm Flat Head
Cap Screw
Hardware at actual size
Caution!
Only use the #M6 × 14 mm Flat Head
Cap Screw (E) for assembly.
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 5 of 10
Attach Base to Worksurface
4.1 Position the base assembly onto
the top. Center the base le to
right over the top. Next center
the feet front to back over the
depth of the top.
4.2 Using the ⅛" drill bit, drill the four
end bracket locations as shown.
Do not drill all the way through
worksurface!
4.3 Install four (4) #12 × " Pan Head Screws (F)
using a #3 Phillips Screw bit in the corner
locations and tighten securely.
Do not overtighten!
3 Install Feet and Glides to Leg Assemblies
3.1 Install feet (Q) using #M6 × 14 mm Flat Head Screws(E)
included with this Frame Set.
3.2 Attach Foot Glide (G) to bottom of the Feet supplied in your Foot Kit.
>¾"
C
L
C
L
4Note: Avoid trip or tip hazards!
For uniquely shaped, non-rectangular worksurfaces, it is the
installers responsibility to position the worksurface to minimize
extended overhangs and position feet fully under the worksurface.
4.1
4.1
4.3
4.2
3.1
3.2
3.2
G
S
G
E
E #M6 × 14 mm Flat Head
Cap Screw
Hardware at actual size
Caution!
Only use the #M6 × 14 mm Flat Head
Cap Screw (E) for assembly.
Flat Foot shown
F #12 × ¾" Pan Head
Screw
Hardware at actual size
F
F
6 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
7 Loop Power Cord through Strain Relief on Control Box
7.1 Loop the Power Cord (N) thought the strain relief
channel on the bottom of the Control Box (H) as
shown. Leave eight inches of slack to rout cord.
7.2 Plug Power Cord (N) into port AC on the Control
Box (H).
7 .3 Lay the Control Box down in installation location
with cables in place.
0.75”
17.90mm
2.00”
50.80mm
Switch Housing
Finish Installing Screws Attaching Base to Top
5.1 Using the ⅛" drill bit, pilot drill the remaining
mounting holes in all bracket locations
as shown.
Do not drill all the way through
worksurface!
5.2 Install the remaining #12 × ¾" Pan Head
Screws (F) to all remaining bracket mounting
locations and tighten securely.
Do not overtighten!
8"
8"
>¾"
N
N
H
H
7.2
7.1
bottom
K #8 × ⅝" Pan Head
Screw
Hardware at actual size
6 Attach Switch
6.1 Using the dimensions shown place the Switch (R)
on the desktop
6.2 Using a Drill and a /" drill bit, drill the two
switch mounting holes as shown.
6.3 Attach the Switch (R) as shown with two (2)
#8 x ⅝" Pan Head Screws (K)
Note: The Switch (R) can be located on the
Right or Le side of the table as required.
6.1
6.3
5.2
5.1
1/1/
K
R
Programmable Switch
Standard or Bluetooth Switch
Note: use the screws provided with Standard & BT-Proswitch
to mount the switch using the diagram above.
5
F
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 7 of 10
8 Attach Control Box & Cable Spools to Worksurface
8.1 Place Control Box (H) in position and use a pencil to mark pilot hole placement. Control Box should be placed
towards rear center of worksurface as shown. Remove Control Box and drill pilot holes where marked.
Do not drill all the way through worksurface!
8.2 With Control Box (H) positioned over pilot holes, attach with two #12 × 2" Flat Head Screws (I).
8.3 Attach Cable Spool (J) with the #12 × ¾" Pan Head Screw (F) to underside of worksurface. If you do not have a
Workrite worksurface, mount Cable Spools (J) in a convenient location between Legs and Control Box.
8.4 Lay out Leg Cables (M) to be sure they reach from the Legs (A) to the Control Box (H).
8.1
8.4
8.4
8.3
8.3
8.2
J
J
H
F
A
A
F
M
M
N
F #12 × ¾" Pan Head
Screw
I #12 × 2" Flat Head Screw
Hardware at actual size
Hardware at actual size
I
8 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
9
Attach Cable Loops and Route Cables
9.1 Connect both of the 1 meter Leg Cables (M) to both Legs (A).
9.2 Wind any remaining slack around Cable Spools (J) to keep cables out of the way while leaving enough slack to
just reach the Control Box (H).
9.3 Attach Cable Loops (L) to underside of worksurface using #8 × ⅝" Pan Head Screw (K) making sure to wrap the
Cable Loop around the cable prior to attaching. Attach cable loops in convenient locations between Legs or
Switch and the Control Box.
K #8 × ⅝" Pan Head
Screw
H
9.2
9.2 9.1
9.1
K
K
L
L
J
J
L
L
Hardware at actual size
M
M
M
A
A
9.3
9.3
9.3
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 9 of 10
10
Connect Leg Cables, Switch Cable and Power Cord to Control Box
10.1 Connect the Leg Cables (M) to the ports “1” & “2” on both sides of the Control Box (H).
10.2 Insert the Switch Cable into port “A1” on the Control Box (H).
M
M
N
HH
Right Leg Cable (M) into Port “1”
Switch Cable into Port “A1”
Power Cord (N ) into Port “AC”
Left Leg Cable into Port "2"
10.2
10.1
10.1
M
M
10 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
#1500383 Rev I
11
Put Work Center Upright and Connect Power Cord to the Power Supply
11.1 Turn the work center over into an upright position.
Caution: Use at least two people to flip or move work centers. HEAVY!
11.2 Plug the Power Cord (N) into the power outlet.
12
Adjust Feet Glides
If necessary, adjust the Foot Glides (G) on work center feet to level the worksurface. Unscrew to increase height,
screw in to decrease height.
Cleaning Instructions
To clean the Sierra legs, apply cleaner to a so cloth.
Suggested cleaners: Windex or Formula 409.
Do not use solvents and do not saturate or spray cleaners directly onto work center base.
Parts & Accessories
Visit http://workriteergo.com/documentation/other/workrite_ergonomics_pricing_specification_guide.pdf for
replacement parts.
13
Initialize Legs
Aer all Legs and the Switch are connected, and the power cord has been plugged in, hold the down arrow on
the Switch until the Legs make a short motion down and then back up. This initializes and synchronizes the
work center Legs.
You must complete this
initialization step or
your work center will
NOT function properly.
Hold down the down arrow
until work center moves
slightly upwards!
N
11.1
11.2
/