Workrite Ergonomics Fundamentals EX/LX 2-Leg 30-48″ Installation guide

Type
Installation guide
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 1 of 7
or
Parts Included
Worksurface Required, Sold Separately:
Width Depth
24" Feet Rectangle 34–48" 23–24"
30" Feet
Rectangle 34–48" 29–30"
Equal Corner 40–48" × 40–48" 23–24"
46–48" × 46–48" 29–30"
120 Degree
34–36" × 34–36" 29–30"
40–42" × 40–42" 29–30"
46–48" × 46–48" 29–30"
Tools Required:
Cordless Drill #2 Phillips Bit
Screwdriver or
Driver/Drill
⅛" pilot drill bit
pencil
332" pilot drill bit
#3 Phillips Bit
Screwdriver or
Driver/Drill
J Power Supply
Qty: 1
O Power Cable - 3.5 meters
Qty: 1
N Leg Cable - 1 meter
Qty: 1
A Master Leg
Qty: 1
C Short Bracket
Qty: 4
D Le End Bracket
Qty: 1
E Right End Bracket
Qty: 1
B Companion Leg
Qty: 1 P Feet
Qty: 2
F 4 mm Allen Wrench
Qty: 1
Q Standard, Bluetooth, or
Programmable Switch
Qty: 1
K Cable Spool
Qty: 1
M " Cable Loops
Qty: 5
H Foot Glide
Qty: 4
G #M6 × 14 mm Flat Head Cap
Screw
Qty: 20
L #8 × ⅝" Pan Head Screw
Qty: 7
I #12 × ¾" Pan Head Laminate
Top Screw
Qty: 21
Assembly & Installation Instructions:
Fundamentals 2-Leg Work Center
FDEX30-48-X / FDLX30-48-X
2 of 7 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
SAVE THESE INSTRUCTIONS
WARNING: Maximum equipment loading of table assembly in addition to specied top is as follows:
Maximum Top Weight: 72 lb (36.4 kg)
Maximum Equipment Load: 125 lb (56.8 kg)
Loading should be evenly distributed over table surfaces.
V = 120 VAC, 60 Hz / 4 A maximum
FLAMMABILITY: All worksurfaces used must meet UL 962 ammability requirements
Flame Spread Rating maximum 200
Smoke Developed Index maximum 450
WORKSURFACE MATERIAL: This frameset is designed to accommodate worksurfaces made from Industrial Particle Board with nominal thickness
of 1.125". If the worksurface is not appropriate or not mounted correctly to the table, it could cause the complete table to be unstable, it may collapse,
and for an adjustable table, the electrical components may fail.
Intended for indoor use only.
For commercial use only.
IMPORTANT SAFETY INSTRUCTIONS:
When using an electrical furnishing, basic precautions should always be followed, including the following:
Read all instructions before using this Fundamentals Work Center.
DANGER: To reduce the risk of electric shock, always unplug this Fundamentals Work Center from the electrical outlet before cleaning or servicing.
WARNING: To reduce the risk of burns, re, electric shock, or injury to persons:
1. Unplug from outlet before putting on or taking off parts.
2. Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.
3. Use this Fundamentals Work Center only for its intended use as described in these instructions, do not use attachments not
recommended by the manufacturer.
4. Never operate this Fundamentals Work Center if it has a damaged cord or plug, is not working properly, has been dropped
or damaged, or dropped into water. Return the furnishing to a service center for examination and repair.
5. Keep the cord away from heated surfaces.
6. Do not operate outdoors.
7. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
8. To disconnect, remove plug from outlet.
9. Do not exceed maximum load recommendations.
Polarized Plug Instructions (Only applicable to products having a polarized plug power cord):
Some products include a polarized plug—see Figure A (One A/C plug blade wider than the other)—to reduce the risk of
electrical shock. A polarized plug only ts a polarized power outlet one way. If the polarized plug does not t properly into the
electrical outlet turn the power plug over to see if it then ts properly and fully into the outlet. If the plug does still does not t
the outlet, contact a certied electrician to install the correct matching polarized electrical outlet.
Caution: Never modify the power cord plug in any way
Double-Insulated Products Instructions:
Some products are double-insulated. No means of grounding is required or provided on a double-insulated product; nor is a
means for grounding to be added to the product. The plug in a double insulated system is shown in Figure A. Double-insulated
products are indicated with markings of “double-insulated” or the “double box symbol” or both.
Grounding Instructions (For grounded electric products only):
Products with grounded power cords are for use on a nominal 120 V circuit and has a grounded plug as shown in Figure B
Make sure the product is connected to an electrical outlet having the same conguration as the plug shown in Figure C.
Caution: Never modify, remove, or use adaptors that eliminate the ground connections from the grounded power cord
A/C Power:
Products sold in North America and other regions are 120 V A/C as marked on the power supply/control box of the furnishing
and are to be used on a normal 120 V A/C circuit. Always follow the instructions above for power connection using grounded or
double insulated power cords as supplied.
Only use power cord(s) supplied with your electric product
Never modify, alter, use an adaptor, or change the electrical system of this product in any way.
Warning: Doing so may cause risk of electrical shock or re
Illustration Disclaimer—Power Plug and Receptacle Images:
In some cases, the images in this instruction may not match the power cord supplied with your electrical furnishing based on your region.
Plug type, blade size, and shape may change.
Grounding Pin
Figure B
Grounded Outlet
Figure C
Polarized Plug
Figure A
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 3 of 7
Attach Short & Medium Brackets
1.1 Attach Short Brackets (C) using Allen Wrench (F) and Flat Cap
Screws (G) to both legs. Do not tighten screws completely.
1.2 Attach Right End Bracket (E) to sides of the right (Master) Leg (A) using Flat Cap Screws (G). Attach Le End
Bracket (D) to sides of the le (Companion) Leg (B) using Allen Wrench (F) and Flat Cap Screws (G) and tighten
securely.
Note: the right leg will be on your le and vice versa when the assembly is seen upside down.
2 Attach Feet & Install Foot Glides
2.1 Install Feet (P) using #M6 × 14 mm Flat Head Cap Screws (G)
included with this Frame Set.
2.2 Attach Foot Glides (H) to bottom of the Feet supplied in your
Foot Kit.
Be sure the longer end of the
foot goes towards the front
of the work center.
C
C
1
Le (Companion) legRight (Master) leg
front
C
E
D
C
To avoid stripping the threads, always
insert and make the first few turns
of the screw BY HAND with an Allen
wrench (F), ensuring it is in straight.
G
F
G
1.1
1.1
1.2
1.2
1.1
1.1
G
G
G
G
G #M6 × 14 mm Flat Head
Cap Screw
Hardware at actual size
G #M6 × 14 mm Flat Head
Cap Screw
Hardware at actual size
Caution!
Only use the #M6 × 14 mm Flat Head
Cap Screw (G) for assembly.
H
G
P
2.1
2.1
2.2
2.2
2.2
2.2
4 of 7 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
2⅞"
2⅞"
C
L
Position & Attach Legs to Worksurface
3.1 Position le and right leg assemblies
onto the top with the end brackets
2" from the outside le and right
ends of the top and center the feet
front to back over the depth of the
top.
3.2 Using the ⅛" drill bit, drill the four
end bracket locations as shown.
Do not drill all the way through
worksurface!
3.3 Install four (4) #12 × ¾" Pan Head
Screws (I) in corners and tighten
securely.
Do not overtighten!
I #12 × ¾" Pan Head
Laminate Top Screw
Hardware at actual size
3
Note: For 2-Leg Equal Corner and 120° Worksurface
Mounting Instructions, go to: www.workriteergo.com/instructions
I
I
3.2
3.3
3.3
3.1
3.1
3.1
rear
Finish Installing Screws Attaching Base to Top
4.1 Using the ⅛" drill bit, pilot drill the remaining
mounting holes in all bracket locations
as shown.
Do not drill all the way through
worksurface!
4.2 Install the remaining #12 × ¾" Pan Head
Screws (I) to all remaining bracket mounting
locations and tighten securely.
Do not overtighten!
4.24.1
4
I
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 5 of 7
L #8 × ⅝" Pan Head
Screw
0.75”
17.90mm
2.00”
50.80mm
Switch Housing
1/1/
5.3
5.1
Attach Switch
5.1 Using dimensions shown, place the Switch (Q) on the desktop.
5.2 Using drill and a " drill bit, drill the two switch mounting holes as shown.
5.3 Attach the Switch (Q) as shown with two #8 × " Pan Head Screws (L).
Note: the Switch (Q) can be located on the Right or Le side of
the table as required.
5
Hardware at actual size
L
Q
Programmable Switch
Standard or Bluetooth Switch
Note: use the screws provided with Standard & BT-Proswitch
to mount the switch using the diagram below.
6 of 7 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Connect Leg Cables to Master leg and Companion Leg
7.1 Connect the Leg Cable (N) to the six position connector labeled
“1” on both the Master Leg and the Companion Leg (B).
7.2 Insert the Power Cable (O) into the two position
connector labeled “DC” on the Master Leg.
7.3 Insert the Control Cable into the data
connector labeled “A1” on the Master Leg.
7
Attach Cable Spools and Cable Loops
6.1 Attach Cable Spool (K) with the #12 × ¾"Pan Head Screw (I) to underside of worksurface.
6.2 Attach Cable Loops (M) to underside of worksurface using the #8 × ⅝" Pan Head Screw (L) making sure to wrap
the Cable Loop around the cable prior to attaching.
6
O
B
A
N
N
Control Cable
Control Cable
O
Master Leg
Companion Leg
7.1
7.1
7.2
7.3
7.3
7.2
L
LM
M
M
I
M
M
K
6.1
6.2
L #8 × ⅝" Pan Head
Screw
Hardware at actual size
Workrite Ergonomics | 800.959.9675 www.workriteergo.com 7 of 7
#1500442 Rev H
Connect Power Cable to the Power Supply and put work center upright
8.1 Connect the Power Cable (O) to the Power Supply (J).
8.2 Turn the table over into an upright position.
8.3 Plug the Power Cord into the power outlet.
Never connect or remove leg or
control cables when power is
connected! Doing so will damage
the Master Leg.
Initialize Legs
Aer all legs and the control are connected, and the power cord has been plugged in, hold the down arrow on
the control until the legs make a short motion down and then back up. This initializes and synchronizes the
table legs.
Adjust Feet Guides
If necessary, adjust leveling guides on table feet to level the worksurface. Unscrew to increase height, screw in to
decrease height.
Set Control Switch Initial Settings (FDLX30-48-X only)
11.1 Press the DOWN button to move table to its lowest position.
11.2 If using a worksurface other than a Workrite top, measure height of table from floor to top of worksurface.
If using a Workrite worksurface, the number to use will be 27.5".
11.3 Press and hold both the UP and DOWN buttons simultaneously. Three dashes will appear. Wait for the numeric
display to return.
11.4 Press the UP button until the display reads 27.5" (for Workrite worksurfaces) or measured height (for others).
11.5 The display will flash when the change has been saved.
Cleaning instructions
To clean the legs, apply cleaner to a so cloth.
Suggested cleaners: Windex or Formula 409.
Do not use solvents and do not saturate or spray cleaners directly to table base.
Hold down the down arrow until table
moves slightly upwards
You must complete
this initialization step
or your table will NOT
function properly.
8
8.1 8.2
8.3
O
J
J
9
11
10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Workrite Ergonomics Fundamentals EX/LX 2-Leg 30-48″ Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI