ELECTRIC LATCH RETRACTION KIT
EXTERNAL MODULE FIRST CHOICE MODELS: 3600 & 3700
Remove Push Bar. Remove Dogging Assembly. Slide the ELR unit into the device base. Align the first set of two
holes over the two base unit holes and attach with the two #10-32 flat head screws supplied. Attach the Linkage to
the device as shown. Re-attach the Push Bar.
P:\INST INSTRUCTIONS\ELR KITS\INST-LR100FAK_FCK-EM REV D 08-22 Page 1
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS
Retrofit Installation Note: 42" or 48" exit devices that have been modified to fit a 36" or smaller opening, may not have
the required space to fit the standard E. L. R. assembly. Always verify the distance from the end of the touchpad to the
end rail, and if necessary, consult with the factory for appropriate selection.
ELECTRICAL DATA
24VDC @ 1A
RED (+) BLK (-)
PATENT #8,851,530
Linkage
Linkage
Align holes with Base and
attach with #10-32 flat
head screws.
ATTACH THE
RETRACTION ARM
TO THE REAR HOLE
ON THE CLEVIS AS
SHOWN
Clevis
Push Bar
Spring Box
Mount to existing
holes in housing
3X #10-32 Flat
Head Screws
Supplied
Mark hole location,
Drill & countersink
farside of housing
NOTE Retro-Fitting Vertical Rod Devices:
Before retro-fitting an electric latch assembly into a vertical device, the following must be done to
ensure proper alignment. Disconnect the vertical rods from the device. Install the electric latch
assembly as shown above. Once the ELR is properly installed energize it so that the push pad is
dogged down, by doing so it will allow for proper alignment for the vertical rods. Finally reconnect
the vertical rods to the device and make the proper adjustments.
P:\INST INSTRUCTIONS\ELR KITS\INST-LR100FAK_FCK-EM REV D 08-22 Page 2
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
+-
24vdc
ACCESS
CONTROL
BOARD PLACEMENT IN
POWER SUPPLY BOX
SDC 600 SERIES
POWER SUPPLY
Latch
Retraction
Module
Pigtail
8 COND
18-22AWG
JACKETED CABLE
100' MAX
BLK
WHT
GRN
ORG
RED
BLU
BRN
YEL
Match colors with provided pigtail
Power
Transfer
Hinge
ALIGN TEMPLATE TO EXISTING HOLES, FALCON/DOR-O-MATIC or FIRST CHOICE
MARK AND DRILL 1 HOLE FOR 10-32 FLT HD
ALIGN FOR
FIRST CHOICE DEVICES
ALIGN FOR
FALCON/DOR-O-MATIC DEVICES
MARK & DRILL
FOR 10-32
TEMP-LR100FCK_FAK
P:\INST INSTRUCTIONS\ELR KITS\INST-LR100FAK_FCK-EM REV D 08-22 Page 3
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM