  • Hello! I am an AI chatbot trained to assist you with the SDC LR100IDCK-EM Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the required space to fit the standard E. L. R. assembly?
    What should be done to ensure proper alignment while retro-fitting vertical rod devices?
    What is the maximum length of the jacketed cable that can be used?
    How to install the linkage to the latch retraction rod?
    What is the electrical data for the LR100IDCK-EM?
LR100IDCK-EM
ELECTRIC LATCH RETRACTION DEVICE KIT
MODELS: 8510, 8530, 8550, 8610, 8620, 8630, 8650,
8710, 8730, 8750, 8810, 8820, 8830 & 8850
P:\INST INSTRUCTIONS\ELR KITS\INST-LR100IDCK-EM REV E 08-22 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
Carefully slide the assembly back out until the linkage JUST makes contact with the latch retraction rod. Tighten set
screws.
ELECTRICAL DATA
24VDC @ 700/200mA
RED (+) BLK (-)
PATENT #8,851,530
4X SET SCREW
LR100 LINKAGE
Remove and discard dogging from device. Slide the Electric Latch Retraction assembly into device and attach the
linkage to the latch retraction rod (short linkage for standard, long linkage for 4' device).
Short
Long
SET
SCREWS
TIGHTEN SET
SCREWS TO
LOCK DEVICE
IN POSITION
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS
Retrofit Installation Note: 42" or 48" exit devices that have been modified to fit a 36" or smaller opening, may not have
the required space to fit the standard E. L. R. assembly. Always verify the distance from the end of the touchpad to the
end rail, and if necessary, consult with the factory for appropriate selection.
P:\INST INSTRUCTIONS\ELR KITS\INST-LR100IDCK-EM REV E 08-22 Page 2
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
NOTE Retro-Fitting Vertical Rod Devices:
Before retro-fitting an electric latch assembly into a vertical device, the following must be done to ensure proper
alignment. Disconnect the vertical rods from the device head. Once the ELR is properly installed energize it so that the
push pad is dogged down, by doing so it will allow for proper alignment for the vertical rods. Finally reconnect the
vertical rods to the device and make the proper adjustments.
+-
24vdc
ACCESS
CONTROL
BOARD PLACEMENT IN
POWER SUPPLY BOX
SDC 600 SERIES
POWER SUPPLY
Latch
Retraction
Module
Pigtail
8 COND
18-22AWG
JACKETED CABLE
100' MAX
BLK
WHT
GRN
ORG
RED
BLU
BRN
YEL
Match colors with provided pigtail
Power
Transfer
Hinge
/