GE ABHG is a modular high and low bay lighting solution, suitable for indoor use. It comes with a variety of mounting options, including chain or cable mounting, direct mounting, indirect mounting for uplighting, and rod mount kit. The luminaire is pre-programmed for either DALI or 1-10V dimming and has an optional dimming line. It also features an AC line for power input and a ground wire for safety. The fixture is designed to be energy-efficient and has a maximum weight capacity of 16.4 kg.

GE ABHG is a modular high and low bay lighting solution, suitable for indoor use. It comes with a variety of mounting options, including chain or cable mounting, direct mounting, indirect mounting for uplighting, and rod mount kit. The luminaire is pre-programmed for either DALI or 1-10V dimming and has an optional dimming line. It also features an AC line for power input and a ground wire for safety. The fixture is designed to be energy-efficient and has a maximum weight capacity of 16.4 kg.

GE
Lighting Solutions
Installation Guide
imagination at work
Modular High & Low Bay Lighting
ABHG-Series CE
Albeo
TM
LED Luminaire
WARNING
RISK OF ELECTRIC SHOCK
Turn power off before inspection, installation
or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all local codes.
• Use only IEC approved wire for input/output
connections. Minimum size 18 AWG (0,75mm
2
).
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• The LED luminaire must be connected to the mains
supply according to its ratings on the product label.
Use an input cord with 3 conductors each with a
cross-section between 1,5mm
2
and 2,5mm
2
of type
HD-21 or HD-22.
• Suitable for use indoors.
Grounding Instructions
• The grounding and bonding of the overall system
shall be done in accordance to local electric code of
the country where the luminaire is installed.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Carefully unpack unit and properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being
transferred to the luminaire.
Mounting
inserts
Tighten screws
Attach to
structural member
Attach to
structural member
Select the appropriate mounting method based on the ordering number logic chosen.
1
Luminaire Installation
Fixture Weight
2
1 2
Loosen screws to remove endcap. Bring AC line through the rst hole on top of the xture
using supplied cable gland. Optionally, bring the dimming
control wires through the second hole on top of the
xture using supplied cable gland.
Electrical Connections (220–240V~)
AC line
For optional
dimming line
ABHG-series
LED Modules Max. Weight
1 module 5,9 kg
2 modules 7,7 kg
3 modules 14,1 kg
4 modules 16,4 kg
3
Chain or Cable Mounting: Please
follow local codes and minimum load
rating guidelines when selecting and
installing a cable or chain.
NOTE: When selecting chain, a
joint in a circular chain link shall
be welded. A joint in a chain link of
another shape shall not be located
within 30 degrees of the vertical
unless welded.
4 5
Direct Mounting: Hang two chains/
cables from a structural member
of the ceiling. Fixture must be
supported independently of an
outlet box. Tighten adjustment
screws on all four mounting inserts,
then attach chain or cable to
mounting inserts on both ends of
xture.
Indirect Mounting for Uplighting:
Hang two chains/cables from a
structural member of the ceiling.
Fixture must be supported
independently of an outlet box.
Attach chain or cable to eye bolt
mounts on both ends of xture.
Note: Mounted xture must have a
minimum distance to lighted objects
of 0,25m.
6
Rod Mount Kit: Attach two rod mount brackets to xture using four 10-32 x 3/8”
pan head screws per bracket. Secure 1/2” threaded rods into structural members
in ceiling. Place a nut on each threaded rod where xture should hang. Slide xture
onto threaded rods and tighten second nut onto rods to secure xture.
Attach to
structural member
Fasten
with nuts
Rod mount
bracket
ALB007-020514
Troubleshooting
Symptom Solution
Luminaire will not turn on. • Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that all wire connectors are properly connected.
• Verify that your input voltage is within specs.
Mounting insert slides
from side to side.
• Check that the mounting insert is properly tightened using the adjustment screws provided.
GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com
The GE brand, logo, and Albeo are trademarks of the General Electric Company.
© 2014 GE. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
4
DALI 1-10V
3
Connect the AC line to the power terminal block as follows:
Brown to L1, Blue to N, and Green/yellow to ground.
Reattach endcap if there is no dimming line.
Optional DALI and 1-10V Dimming: Follow wiring
diagram below. Reattach endcap.
For Step 4: Follow diagram A for DALI or diagram B for 1-10V. The LED luminaire is pre-programmed for either DALI or
1-10V dimming at the factory. Run wires from controller through a different knockout than the AC input wire. At output
side of LED driver, make appropriate connections to the dimming terminal block. Follow lighting controller installation
instructions.
A
DALI Controller
B
1-10V Dimmer
Optional 1-10V Volt Dimming or DALI Lighting Controller
Brown
To AC Main
Blue
Green/Yellow
Violet
Grey
Line
Neutral
Ground
1-10V(+)
1-10V(-)
LED Driver
To 1-10V
Dimmer
Brown
To AC Main
Blue
Green/Yellow
Violet/White
Violet
Line
Neutral
Ground
DALI
DALI
LED Driver
To DALI
Controller
  • Page 1 1
  • Page 2 2
  • Page 3 3

GE ABHG Installation guide

Type
Installation guide

GE ABHG is a modular high and low bay lighting solution, suitable for indoor use. It comes with a variety of mounting options, including chain or cable mounting, direct mounting, indirect mounting for uplighting, and rod mount kit. The luminaire is pre-programmed for either DALI or 1-10V dimming and has an optional dimming line. It also features an AC line for power input and a ground wire for safety. The fixture is designed to be energy-efficient and has a maximum weight capacity of 16.4 kg.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI