Electrical Connections
Carefully remove appropriate
knockout for AC line input wires
(inner knockout for 22mm conduit,
outer knockout for 28mm conduit.
Install supplied cable glands in the
knockout holes for wire protection
and pass supply conduit through the
cable glands.
Optional dimmer: Install supplied
cable glands in the knockout holes
for wire protection and pass supply
conduit through the cable glands.
Connect dimming control wires
(grey and violet for 0-10V or violet
and violet/white strip for DALI) to the
similarly colored xture wire using
the provided terminal.
Connect the green (ground), black
(line) and white (neutral) wires of the
AC line to the similarly colored wires
of the power supply unit using the
provided terminal.
Replace power supply cover by
sliding over the captive screws and
secure by tightening them.
2
4
1 3
AC line
Dimming line
(optional)
Mechanical Installation for Continuous Runs
Continuous runs must begin with
a starter unit. Remove the power
supply side end cap from the starter
unit and save for Step 5.
Continuous runs must begin with a starter unit which is suspended at both ends. The power supply side end cap from the starter unit
must be removed and used to terminate the run.
Remove the PSU cover from the
previously hung luminaire if present.
1 2 3
To add a continuous unit to a
continuous run, rst suspend the
new unit per the instructions above.
Position the non-power-supply end of
the luminaire near the power-supply
end of the previously hung luminaire.
New unit
Previously
hung unit
Wiring Diagrams
DALI
Fixture
Neutral
Ground
Line
DALI
DALI
White
Green
Black
Violet/White
Violet
White
Green
Black
Violet
Grey
Fixture
0-10V
Neutral
Ground
Line
(0-10V) +
(0-10V) –