The GE EL Series offers a range of lighting options for both indoor and outdoor areas, providing energy efficiency and reliable performance. With its IP66 rating, the EL Series can withstand harsh weather conditions, making it ideal for outdoor use. Additionally, its wide voltage range of 120-277V allows for flexible installation options.

GE EL Series: Your Versatile Lighting Solution for Indoor and Outdoor Applications

The GE EL Series offers a range of lighting options for both indoor and outdoor areas, providing energy efficiency and reliable performance. With its IP66 rating, the EL Series can withstand harsh weather conditions, making it ideal for outdoor use. Additionally, its wide voltage range of 120-277V allows for flexible installation options.

GE
Lighting
Installation Guide
imagination at work
(For EP and EL Series)
Remote Driver Enclosure
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N’utilisez que des ls approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 18 AWG.
Features
• For remote location application
• Suitable for dry or damp locations
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 120-277 VAC,
50/60 Hz (in 120-277V application).
For model code: EL-DKIT360-S-347V and
EP-DKIT400-S-347V, the unit must be supplied
with 347 VAC, 60 Hz (in 347V application).
Connected to an individual properly grounded
branch circuit, protected by a 15 or 20 ampere
circuit breaker. Use min. 75°C supply conductor.
Grounding Instructions
The grounding and bonding of the overall
system shall be done in accordance with
National Electric Code (NEC) Article 600 and
local codes.
Provided in the Package
• Power supply - rated 120-277V, 50/60Hz
• Grounding screw and washer
• For model code EP-DKIT400UEVVA and EL-DKIT360-S-LN use
Lutron Ecosystem 0-10V interface
• For model code EP-DKIT400-S-347V and EL-DKIT360-S-347V
Transformer GETR480/277-250W
Tools and Components Required
#2 Phillips head screwdriver
UL Recognized conduit connections per NEC/CEC for
nominal conduit trade sizes ½” or ¾”
UL Recognized wire connectors
Optional
If using a dimming controller, connect matching-colored
wires together.
Risk of Damage
Make sure that supply connection, light xture wiring, and
dimming cables are connected to proper driver inputs. Wrong
connection may cause damage to the product.
Must use UL approved conduit ttings for all enclosure box
connections to prevent wire cuts by sharp edges and excessive
strain on wiring.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Wiring Diagrams
X
X
X
PSU
DALI/PROG COMMON
X
(0-10V) +, DALI/PROG RNTC
(0-10V) – RSET
+
Light
Engine
+
Line
Neutral
Remote Switch
1-10V
(Optional)
VIOLET
VIOLET-WHITE BLUE-WHITE
BLACK-WHITE
YELLOW
GREY
RED
BLUE
BLACK
WHITE
(0-10V) –
(0-10V) +, DALI/PROG
GND
N
L
X
X
X
X
PSU
DALI/PROG
COMMON
(0-10V) +, DALI/PROG
RNTC
(0-10V) –
RSET
+
Light
Engine
+
Line
Neutral
Remote Switch
DALI
(Optional)
VIOLET
VIOLET-WHITE
GREY
RED
BLUE
BLACK
BLUE-WHITE
BLACK-WHITE
YELLOW
WHITE
(0-10V) +, DALI/PROG
DALI/PROG
GND
N
L
BLACK
RED
BLACK
RED
Driver Installation (EP-DKIT400 and EL-DKIT360-S)
1/4-20 screws
Electrical Connections
Dimming Type: 1-10V
Dimming Type: DALI
1
2
Remove driver enclosure cover. Carefully remove
knockout for AC line input wires.
Install driver enclosure to a suitable structural member
using two ¼-20 screws.
Remove cover
Lutron Interface
0-10V
Output
GND
N
Switched Hot/Out
Constant Hot/In
EcoSystem
Digital Link
PSU
Light Engine
Line
Neutral
DALI
DALI/0-10V
0-10V
Red
Black
Red
White
Violet
White
White
Blue
Black
Grey
Orange
Black
+
+
GND (Green-Yellow)
Neutral (White)
Line (Black)
EcoSystem Link E1
EcoSystem Link E2
AC line
Violet/White
21
Carefully place enclosure cover next to electrical
enclosure. Follow the wiring diagram, insert stripped wires
into Lutron interface connector as described in next step.
See previous steps 1 and 2.
1/4-20 screws
Driver Installation (EP-DKIT400-LN and EL-DKIT360-S-LN)
Wiring Diagram
Electrical Connections
4
Replace electrical enclosure cover. Enclosure cover is on
top for installation.
3
First connect the black (line) and white (neutral) wires
of the AC line to the black and white wires of the power
supply using 18-24AWG (0.82-2.08mm
2
) twist-on wire
connectors. Next connect the luminaire wires to the blue
and red wires of the power supply. Connect the green
wires to the ground screw.
To dimming
controller
(optional)
AC line
From
luminaire
a) Grey
b) Violet
c) Green-yellow
AC line
EcoSystem line
Black
e) Orange
d) White
3 4
Connect Driver wires to Lutron interface as follows:
a) Driver 0-10V grey wire to Lutron grey connector.
b) Driver 0-10V violet wire to Lutron violet connector.
c) One green-yellow wire to Lutron green connector.
d) One Driver white wire to Lutron white connector.
e) Driver orange wire to Lutron orange connector.
Push out appropriate size knockout tabs and install
approved conduit connectors for both the AC and
EcoSystem lines.
5 6
Connect AC line to black, white and green wires from
Lutron interface with twist-on wire caps. Connect
EcoSystem bus wires to the two purple Lutron
connectors (Link E1 and E2).
Next connect the luminaire wires to the blue and red
wires of the power supply. Connect the green wires to
the ground screw.
After completing connections, replace enclosure cover
and screw down M4 screws and lock washers. Make sure
screws are tight and cover is secured.
E1 and E2
X
X
X
PSU
DALI/PROG COMMON
X
(0-10V) +, DALI/PROG RNTC
(0-10V) – RSET
+
Light
Engine
+
Line
Neutral
Remote Switch
1-10V
(Optional)
VIOLET
VIOLET-WHITE BLUE-WHITE
BLACK-WHITE
YELLOW
GREY
RED
BLUE
BLACK
WHITE
(0-10V) –
(0-10V) +, DALI/PROG
GND
N
L
Transformer
BLACK
RED
Dimming Type: 1-10V
X
X
X
X
PSU
DALI/PROG
COMMON
(0-10V) +, DALI/PROG
RNTC
(0-10V) –
RSET
+
Light
Engine
+
Line
Neutral
Remote Switch
DALI
(Optional)
VIOLET
VIOLET-WHITE
GREY
RED
BLUE
BLACK
BLUE-WHITE
BLACK-WHITE
YELLOW
WHITE
(0-10V) +, DALI/PROG
DALI/PROG
GND
N
L
BLACK
RED
Transformer
Dimming Type: DALI
Driver Installation (EP-DKIT40D-S-347V and EL-DKIT36D-S-347V)
Wiring Diagrams
1
See previous steps 1 and 2.
2
First connect the black (line) and white (neutral) wires of
the AC line to the black and red wires of the transformer
using 18-24AWG (0.82-2.08mm
2
) twist-on wire
connectors. Next connect the luminaire wires to the blue
and red wires of the power supply. Connect the green
wires to the ground screw.
Electrical Connections
To dimming
controller
(optional)
AC line
From
luminaire
1/4-20 screws
Replace driver enclosure cover. Enclosure cover is on top
for installation.
3
Troubleshooting
Symptom Solution
Luminaire does not light
• Check input voltage and check power supply input/output connections.
• Check circuit breaker
Luminaire is dim • Maximum recommended supply wire length is exceeded.
Luminaire is blinking
• Ensure power supply temperature does not exceed its maximum rating.
• Refer to the tc point located on power supply.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD
complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
IND084-101113
GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand, logo, Lumination are trademarks of the General Electric Company. USG and Logix are trademarks of USG Interiors, LLC.
© 2013 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

GE EL Series Installation guide

Type
Installation guide

GE EL Series: Your Versatile Lighting Solution for Indoor and Outdoor Applications

The GE EL Series offers a range of lighting options for both indoor and outdoor areas, providing energy efficiency and reliable performance. With its IP66 rating, the EL Series can withstand harsh weather conditions, making it ideal for outdoor use. Additionally, its wide voltage range of 120-277V allows for flexible installation options.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI