Skov DA 1211 Flange Inlet Anti-freeze Mounting Guide

Type
Mounting Guide
DA 1211 Flange Inlet
Anti-freeze
Mounting Guide
604242 • 2023-11-24
DA 1211 Flange Inlet
Mounting Guide 3
Product and Documentation Changes
SKOV A/S reserves the right to change this document and the product herein described without further notice.
In case of doubt, please contact SKOV A/S.
The date of change appears from the front and back pages.
Note
All rights belong to SKOV A/S. No part of this manual may be reproduced in any manner whatsoever without
the expressed written permission of SKOV A/S in each case.
All reasonable efforts have been made to ensure the accuracy of the information contained in this manual.
Should any mistakes or imprecise information occur in spite of this, SKOV A/S would appreciate being noti-
fied thereof.
Irrespective of the above, SKOV A/S shall not accept any liability with regard to loss or damage caused or
alleged to be caused by reliance on any information contained herein.
Copyright by SKOV A/S.
DA 1211 Flange Inlet
Mounting Guide
1 Product description ....................................................................................................................................... 5
2 Product survey ............................................................................................................................................... 6
2.1 Flange inlet ................................................................................................................................. 7
2.2 Accessories................................................................................................................................ 7
3 Mounting guide............................................................................................................................................. 12
3.1 Recommended tools................................................................................................................ 12
3.2 Mounting of sandwich screws................................................................................................ 13
3.3 Wall inlet positioning............................................................................................................... 14
3.4 Mounting inlet .......................................................................................................................... 14
3.4.1 Preparing hole in wall................................................................................................................. 14
3.4.2 Mounting of inlet in wall.............................................................................................................. 16
3.4.3 Foaming ..................................................................................................................................... 18
3.4.4 Mounting the net ........................................................................................................................ 19
3.4.5 Mounting of external flange and net........................................................................................... 19
3.4.6 Pointing ...................................................................................................................................... 20
3.4.7 Check the assembly................................................................................................................... 20
3.5 Mounting of operation kit........................................................................................................ 21
3.5.1 Operation kit with advanced inlet control ................................................................................... 21
3.5.1.1 Check the position of the string at advanced inlet control.......................................................... 23
3.5.2 Regulation set with advanced inlet control................................................................................. 24
3.5.2.1 Check the position of the string at advanced inlet control.......................................................... 27
3.5.3 Adjustment of wall inlets ............................................................................................................ 28
3.6 Mounting of accessories......................................................................................................... 28
3.6.1 Air direction plate ....................................................................................................................... 28
3.6.2 Extension rod ............................................................................................................................. 30
3.6.3 Baffle plate ................................................................................................................................. 31
3.6.4 Regulation set for 2 inlets .......................................................................................................... 31
3.6.5 LPV door set for pull rod ø8 ....................................................................................................... 32
3.6.6 Door set for wire drive................................................................................................................ 32
4 Maintenance.................................................................................................................................................. 33
4.1 Recycling/Disposal .................................................................................................................. 33
5 Technical data .............................................................................................................................................. 34
5.1 Dimensioned sketch ................................................................................................................ 35
5.1.1 Flange inlet ................................................................................................................................ 35
5.1.2 Light trap complete/outside flange ............................................................................................. 35
5.1.3 Inlet Cover.................................................................................................................................. 36
5.1.4 Light trap for inlet cover ............................................................................................................. 36
5.1.5 Fly screen for inlet cover............................................................................................................ 37
DA 1211 Flange Inlet
Mounting Guide 5
1 Product description
The DA 1211 anti-freeze flange inlet is designed for areas with extremely low outside temperatures. The inlet
frame itself is insulated to reduce the formation of ice.
Flange inlet DA 1211 is a universal wall inlet which is used for ventilating livestock houses with natural, LPV or
Combi-Tunnel ventilation.
The inlet is fixed on the inside wall by screws through the flange itself. It cannot be built or cast directly into wall
elements.
The Advanced inlet control of the inlets is patent pending and is supplied with a regulation set which makes it
easy to adjust the air inlet in accordance with the current conditions.
The inlet is easy-to-clean due to its open and smooth construction. Also, the thermoplastic stands high-pressure
cleaning. Furthermore, the choice of material makes the inlet resistant to UV radiation. The inlet is made of high-
impact material; it is dimensionally stable and 100% recyclable.
DA 1211 Flange Inlet
6 Mounting Guide
2 Product survey
DA 1211 Flange Inlet
Mounting Guide 7
2.1 Flange inlet
433044 DA 1211 flange inlet 11 cm, Anti-freeze
The DA 1211 anti-freeze flange inlet is designed for areas with extremely
low outside temperatures. The inlet frame itself is insulated to reduce the
formation of ice.
The inlet is supplied with operation kit and parts for Advanced Inlet Control.
The 4 screws for mounting must be ordered separately. When mounting in
a sandwich wall, 351585 can be used.
2.2 Accessories
433016 DA 1200 net, fine 10x10 mm
The net for DA 1211/1211B is ordered separately. Fine net prevents the
ingress of mice and rats.
Net size 10x10 mm. Self-supporting, but it is recommendable to fasten it
with screws if used together with the extension.
Fine net reduces inlet capacity by approx. 10 %.
One per inlet.
433015 DA net, coarse 65x20 mm
The net for DA 1211/1211B is ordered separately.
Net size 65x20 mm. Self-supporting, but it is recommendable to fasten it
with screws if used together with the extension.
Coarse net does not reduce the inlet capacity.
One per inlet.
433117 DA 1211/1911 net holder set for 25 inlets
The net holder is used for mounting the net when mounting is required on
the outer wall instead of directly on the inlet, for example, at deep window
openings.
Contains 100 pcs.
One set for each 25 inlets.
433043 DA 1211/1911 screw kit f. flange, 10/5 set
Used for mounting of flange inlet. Contains 40 4.8x70 tapping screws.
DA 1211 Flange Inlet
8 Mounting Guide
433054 DA 1211 screw kit x 10 f. ceiling mount
Used when DA 1211 is used for Combi-Diffuse.
One set for each 10 inlets.
433112 DA 1200 air direction baffle, short
The air direction baffle is 7.5 cm. Air direction baffle (short/long) can be
used for adjusting the air jet under cold weather conditions and to avoid ad-
hesion on the wall. The baffle is used for all inlets. However, in connection
with 2 rows of inlets the baffle is only required for the top row if the inlets
are placed right above each other.
One per inlet or one for every second inlet.
433114 DA 1200 air direction baffle, long incl. side plate
The air direction baffle is 15 cm and includes side plates. Air direction baffle
(short/long) can be used for adjusting the air jet under cold weather condi-
tions and to avoid adhesion on the wall. The baffle is used for all inlets.
However, in connection with 2 rows of inlets the baffle is only required for
the top row if the inlets are placed right above each other.
Long air direction baffle is applied where the air jet range and Coanda-ef-
fect are particular important, for instance in wide livestock houses.
One per inlet or one for every second inlet.
433014 DA 1200 baffle plate
For reduction of external actions on the DA 1200 or DA 1211/1211B, baffle
plates are offered in connection with one or more of the following condi-
tions:
The volume of the livestock house is low (narrow and low livestock
house with a flat ceiling)
In detached wind-affected buildings without windbreaks and the like.
The baffle plate must be mounted on all inlets in the same room and are not
to be used together with Advanced Inlet Control.
The baffle plate increases the requirements to the tightness of the building
and cannot replace external windshield.
The baffle plate does not reduce the inlet capacity.
One per inlet.
560195 DA 1200 regulation set w. long U-shackle
Used where obstacles such as lopsided walls, steel trusses projecting up to
70 mm out from the wall, etc. impede the free movement of the pull rod.
The current system of Advanced inlet control cannot be used with the kit
and therefore an extra string with spring to reduce the slack is included by
which you can make Advanced inlet control.
The inlet flap should as a maximum open to a horizontal position; otherwise
it may overload the winch motor.
One per inlet.
DA 1211 Flange Inlet
Mounting Guide 9
433039 DA 1200 extension piece 240 mm
S433037B DA 1200 extension piece 400 mm, type B
The extension rod is used if you want to run the pull rod round heavy con-
crete pillars or the like, where it is not possible to run the pull rod directly
through the pillar by making a through-going hole. The extension rod is
made of stainless steel.
One per inlet.
401902 DA 1000/1200 single operation set
If individual operation of each inlet is required, DA 1200 single operation
set is mounted.
One per inlet.
401349 All-purpose holder for pull rod
If the distance between the inlets exceeds 2 m, the pull rod will bend down-
wards causing inaccuracies if all-purpose holders are not used.
One unit for each 2 meters free-hanging pull rod.
433021 DA 1200 regulation set for 2 inlets
DA 1200 regulation set for 2 inlets at different heights.
A pull rod row for each row of inlets is preferred and using 433021 should
therefore be regarded as a cheaper alternative.
One for each inlet in the upper row.
413214 LPV door set for pull rod 8 mm
If there are doors or the like in the wall where the inlets are mounted and
you temporarily want to end the pull rod, a special kit containing the neces-
sary parts can be acquired. The kit makes it possible to manually maintain
correct ventilation level and easily reestablish the pull rod.
One per door.
413223 Door set for wire tension
The mounting set is used where the pull rod is directed along the door
frame by means of wire and reels.
One per door.
DA 1211 Flange Inlet
10 Mounting Guide
433065 DA 1211 light trap complete
Used for DA 1211/1211B flange inlet if dimming of light is required.
The light-tightness of the light trap is 99.9 %, corresponding to 20,000 lux
outside and 0.05 lux inside (0.05 lux corresponds to 2.5 ppm).
One per inlet.
433281 DA 1211 external flange
The flange is included in 433065 but can also be mounted on the outside in
connection with DA 1211/1211B flange inlets to
increase the output to the same level as DA 1200. Correct the number of
inlets, if needed.
make a nicer finish on the outside of the building and the net can subse-
quently be mounted on the flange.
433281 can be used when the lateral distance between the inlets is 5 cm or
less.
One per inlet.
433066 DA 1200 light trap ex. flange
Used for retrofitting on DA 1200/1211/1211B when the flange is already on
the building and light dimming is required.
The light-tightness of the light trap is 99.9 %, corresponding to 20,000 lux
outside and 0.05 lux inside (0.05 lux corresponds to 2.5 ppm).
One per inlet.
433155 DA 1200 inlet cover
DA 1200 inlet cover can be used together with the inlets of the DA 1200 se-
ries.
The inlet cover is designed to protect the livestock house against rain/snow
and to provide a certain amount of wind and light dimming effect.
One per wall inlet.
433312 DA 1200 light trap for inlet cover
DA 1200 light trap for inlet is always used together with DA 1200 inlet
cover.
The light trap prevents a large amount of daylight from seeping into the
building ("brown out"). The light trap is made of injection-molded PP
(polypropylene) which is dirt-repellent and easy to clean.
Use one for each DA 1200 inlet cover.
DA 1211 Flange Inlet
Mounting Guide 11
433334 DA 1200 fly screen
DA 1200 fly screen for inlet cover is always used together with DA 1200 in-
let cover.
The fly screen prevents the ingress of flies and the screen is self-support-
ing.
Can only be used for inlets in 1 row.
With regular and sufficient cleaning, the capacity of the inlet is not reduced
by the use of the fly screen.
One per inlet.
433317 Fly screen - 25 m x 1.37 m
Fly screen on a roll prevents the ingress of flies.
With regular and sufficient cleaning there will be no significant pressure
loss, but an emergency opening should be provided via bypass in case the
fly screen is choked.
Use 1 m2 fly screen per 2000 m3/h max. air.
433138 DA 1200 hen net, hinged
The hen net prevents the fledged hens from sitting in the air inlet. The net is
top-hinged, allowing easy access when servicing the inlet.
Screw kit (560333) is ordered separately.
560333 Screw kit DA 1200/1911 hen net
The screw kit is used to mount the hen net.
1 set per hen net.
351585 Tapp. screw 5x30 pan TX25 ZnNi spec.
Used when mounting inlet and accessories in sandwich walls.
DA 1211 Flange Inlet
12 Mounting Guide
3 Mounting guide
Check that all ordered parts are present and undamaged prior to starting the work. Read the directions carefully
before starting mounting.
3.1 Recommended tools
See a list of tools recommended for the installation of the flange inlet below.
Item Description
Cordless drill
Jigsaw
Saw
Hammer
Screwdriver
Sealant gun
Marker pen
Tape measure
Spirit level
Water pump (multi-grip) pliers
Utility knife
Chisel
Try square
DA 1211 Flange Inlet
Mounting Guide 13
Item Description
Atomizer
Wedge
Foam gun
Ladder
3.2 Mounting of sandwich screws
To ensure that the screw makes the right thickening and the best possible thread on the back, the correct hole
must be drilled first and the screwing must be done with the correct momentum depending on the thickness of
the metal in the sandwich panel.
Diameter of
screw [mm]
Thickness of metal in
sandwich panel
[mm]
Size of holes in
sandwich panel
[mm]
Tightness
torque
[Nm]
5
0.63 - 0.75 ø3.8 2.5
0.75 - 0.88 ø4.1 3.0
0.88 - 1.00 ø4.2 3.5
1.00 - 1.25 ø4.3 3.5
1.25 - 1.50 ø4.4 4.0
DA 1211 Flange Inlet
14 Mounting Guide
3.3 Wall inlet positioning
The positioning of the inlet in a wall depends on the layout of the building and the house layout. The positioning
may therefore only be made according to directions communicated by SKOV A/S or representatives of the com-
pany.
The inlet must be placed horizontally in the wall. The inlet flap should be pointing into the livestock house.
Place the insulation of the brickwork against the inlet all the way round (like in other categories of constructions).
This way you prevent a cold bridge along the side of the inlet from being formed.
The inlet is fixed on the inside wall by screws directly through the flange itself, see section Mounting of inlet in
wall [}16]. In connection with brick and concrete walls, use mounting foam to fix the inlet, see section Foaming
[}18].
3.4 Mounting inlet
3.4.1 Preparing hole in wall
Mark out the correct number of holes according to measurements. Be aware of tolerance.
Distance to coil spring
Min. distance between holes
Min. distance to the wall on the
tensile side, see table below
1200 mm
571 mm
100 mm
xxx mm
280 mm
Distance to the ceiling
283 mm
571 mm
Positioning of actuator Min. distance to the wall on the tensile side
[mm]
Min. 2100 mm
637 mm
637
700 mm 950 mm
1650
Min. 2100 mm
2100
DA 1211 Flange Inlet
Mounting Guide 15
Remember always to use a spirit level.
Drill 4 holes of roughly 10 mm right through the wall.
Cut the holes.
DA 1211 Flange Inlet
16 Mounting Guide
3.4.2 Mounting of inlet in wall
Make sure that the inlet flap is closed.
Use the 2 center marks in the upper flange and the
center marks 2 in the lower flange.
Drill ø6 mm holes in the flange using the center marks.
Use the holes in the flange to mark out holes in the
wall.
An extension piece must be used if the wall thickness
exceeds 11 cm.
Push the extension piece on to the inlet before mount-
ing in the wall.
DA 1211 Flange Inlet
Mounting Guide 17
When mounting in oblique walls it is important to make
corrections otherwise the flap will not close tightly when
the inlet is inserted.
It may be necessary to mount a heavy-duty plate or
wedges between the inlet and the wall in order to avoid
distortion of the inlet.
Use the 2 wedges enclosed with the inlet.
Mount the inlet in the wall using the screws suitable for
the wall type.
At sandwich walls see table Mounting of sandwich
screws [}13].
Remember to use a spirit level and make sure not to
over-tighten the screws as they are tightened directly
against plastic.
Each time a screw is tightened, check that the inlet flap
still closes tightly. Otherwise, you must adjust the
wedges until the inlet flap closes tightly again.
Remove the redundant part of the wedge when all the
screws have been tightened.
DA 1211 Flange Inlet
18 Mounting Guide
3.4.3 Foaming
SKOV A/S recommends one-component polyurethane foam or similar.
Check how much the foam expands before foaming.
Wet the faces with water from a mist sprayer before
proceeding with the foaming.
Foam around the inlet, as shown in the drawing.
Foam the entire depth of the inlet in the corners and
approx. 100 mm to each side of the corners.
It is important only to foam the edge in the middle of
the inlet as the joint would otherwise make the inlet
skew.
Push the foam in against the inlet (5-10 mm) after the
foam has dried a little to allow adequate space for
pointing.
We recommend using a sealant gun.
DA 1211 Flange Inlet
Mounting Guide 19
3.4.4 Mounting the net
Mount the net on the inlet until the click engages.
3.4.5 Mounting of external flange and net
Mount the external flange on the inlet (the wall thick-
ness must be minimum 50 mm).
Next mount the net on the external flange until the click
engages.
DA 1211 Flange Inlet
20 Mounting Guide
3.4.6 Pointing
SKOV A/S Sikaflex AT Connection, single-component MS polymer, or similar.
Complete by applying a sealing edge both inter-
nally and externally when the foam is dry.
Point flat the surface of the pointing.
If the distance between the wall and the edge of
the inlet exceeds 6 mm, sealant tape can be used
before making a sealing edge.
3.4.7 Check the assembly
Check that all the edges are tight and that the inlet flap
closes tightly at both ends.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Skov DA 1211 Flange Inlet Anti-freeze Mounting Guide

Type
Mounting Guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI