Danfoss SpeedUp Wall Heating - Dry construction User guide

Type
User guide
Application Sheet
SpeedUp Wall Heating
Dry construction with wood battens
Fibre reinforced plasterboard
1 Dry walling screws
2 Wood battens, 30 mm
3 SpeedUp panel, 30 mm
4 Danfoss composite pipe 16 x 2 mm
5 Fibre reinforced plasterboard, 12.5 mm
Technical Data Drywall construction with wood battens
Wall Covering 12.5 mm Fibre reinforced plasterboard or similar
Constructional thickness 42.5 mm Dimensions without unfinished wall
Thermal resistance R 0.86 m²K / W Thermal resistance value for SpeedUp panel
Pipe spacing 125-250 mm EZ = 125; CZ = 250;
Requirements and specialities
Surface smoothness +/- 3 mm per 1 m. Observe building regulation requirements con-
cerning thermal insulation. Moisture condensation can occur and should be taken into
consideration when planning wall heating on outer walls or walls between heated and
unheated rooms.
Wall coverings
Fermacell/fibre reinforced plasterboard: 0.32 W/m²K; maximum flow temperature: 55°C;
form board butt joints as glued joint. Form wall attachment with an elastic acrylic joint
or joint filler on divider.
Construction:
Refering to EN 1264
Construction number 602
VAGJA102 © Danfoss 06/2010
1
2
3
4
5
  • Page 1 1

Danfoss SpeedUp Wall Heating - Dry construction User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI