Danfoss SpeedUp Eco Wall Heating - Fibre reinforced plasterboard User guide

  • Hello! I am an AI chatbot trained to assist you with the Danfoss SpeedUp Eco Wall Heating - Fibre reinforced plasterboard User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Fibre Reinforced
Plasterboard
1 Dry walling screws
2 SpeedUp Eco panel, 30 mm
3 Danfoss composite pipe 16 x 2 mm
4 Fibre reinforced plasterboard, 12.5 mm
Technical Data
Wall heating, SpeedUp Eco dry construction
Wall covering 12.5 mm Fibre reinforced plasterboard or similar
Construction thickness 42.5 mm Dimensions without unfinished wall
Thermal resistance (R) 0.75 m²K/W Thermal resistance value for SpeedUp Eco panel
Pipe spacing 125-250 mm EZ = 125; CZ = 250;
Requirements and
specialities
Surface smoothness +/- 3 mm per 1 m. Observe building regulation
requirements concerning thermal insulation. Moisture condensation can occur
and should be taken into consideration when planning wall heating on outer
walls or walls between heated and unheated rooms.
Wall coverings Fermacell/fibre reinforced plasterboard: Thermal conductivity: 0.32 W/m²K;
maximum flow temperature 55°C; form board butt joints as glued joints. Form
wall attachment with an elastic acrylic joint or joint filler on divider.
Construction Referring to EN 1264.
Construction number 611
Application Sheet
SpeedUp Eco Wall Heating - Fibre Reinforced
Plasterboard
Danfoss Heating Solutions VAEUM202 © Danfoss 03/2011 1
Application Sheet SpeedUp Eco Wall Heating - Fibre Reinforced Plasterboard
Danfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone:+45 7488 8000
Fax: +45 7488 8100
www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective
companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 VAEUM202 © Danfoss 03/2011 Danfoss Heating Solutions
/