INSTALLATION VERS (02)
NOTES:
• Field modifications must comply with Q-Tran’s installation methods otherwise warranty is null and void
Wiring Details
.25"
Green = Green
Blue = Blue
Red = Red
Black = +24V
LEAD WIRE
.25"
LEAD WIRE
Blue = SW
Red = WW
Black = +24V
.25"
LEAD WIRE
Red = WW
Blue = CW
Black = +24V
.25" LEAD WIRE
Red = +24V
Black = Negative
.25"
Red = +24V
Black = Negative
LEAD WIRE
STATIC WHITE (SW), STATIC WHITE HIGH EFFICACY (SW-HE), AND STATIC COLOR (SC)
DYNAMIC WHITE (DW)
DYNAMIC WHITE HIGH EFFICACY (DW-HE)
WARM DIM (WD)
RGB
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-08-08-22
INSTALLATION VERS (02)
NOTES:
• Field modifications must comply with Q-Tran’s installation methods otherwise warranty is null and void
#4 x 5/8” flat head screw
SCREW FOR CONCEALED CLIP
CONCEALED CLIP INSTALL
Using the #4 x 5/8” flat head screws, mount the
concealed clip. The first and last clip should be
placed 4” inward from each end of the VERS.
NOTE: 2 clips provided for 4’ or less;
4 clips provided for greater than 4’
NOTE: The VERS makes a secure connection with
the concealed clip by tilting and snapping on.
SECTION VIEW
Mount the VERS fixture by snapping onto the
concealed clips.
1 2
ASSEMBLED
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-08-08-22
INSTALLATION VERS (02)
NOTES:
• Field modifications must comply with Q-Tran’s installation methods otherwise warranty is null and void
#6 flat head screw
6-32 Set screw
1/16" Drive size
SCREW FOR MAGNETIC MOUNT ACCESSORY
MAGNET INSTALL
Using the #6 flat head screws, mount two screws
into the 12” magnet bracket through the slotted
holes at each end.
Using the supplied set screws fasten the CLS
endcap that was removed, and secure the magnet
clips into your desired location.
NOTE: 1 magnet clip needed per foot.
NOTE: The magnet clips should be offset to the flat heads used to
secure the bracket, to maximize magnetic connection.
Unscrew the CLS VERS endcap using the supplied
allen key, and slide in the magnet clips.
Drop the assembled VERS fixture into the mounted
magnet bracket, the bracket should sit within the
extrusion as pictured below.
1
3
2
4
SECTION VIEW
.925
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-08-08-22
INSTALLATION VERS (02)
NOTES:
• Field modifications must comply with Q-Tran’s installation methods otherwise warranty is null and void
MAGNET INSTALL
COVE INFO
The VERS magnet install requires a .925” cut out to be recessed
(The magnet bracket should be centered in the millwork).
NOTE: Height of millwork for recessed VERS should be based off the product specific dimensions found on the cutsheet.
NOTE: For magnet installations requiring seismic precautions, monofiliment may be used with magnet clip as pictured below.