Q-Tran Q-TRAN LUME-01 Fully Encapsulated Flexible Fixture is a versatile lighting solution suitable for various applications like offices, retail stores, and hospitality venues. This fixture can be surface-mounted or recessed in millwork and offers multiple mounting options for seamless integration. It is not rated for walkover applications. The product comes with a 24VDC input voltage and requires use with a compatible Class 2 power supply unit. Q-Tran provides options for mounting clips, mounting channels, and Q-Angle accessories to facilitate different installation methods.

Q-Tran Q-TRAN LUME-01 Fully Encapsulated Flexible Fixture is a versatile lighting solution suitable for various applications like offices, retail stores, and hospitality venues. This fixture can be surface-mounted or recessed in millwork and offers multiple mounting options for seamless integration. It is not rated for walkover applications. The product comes with a 24VDC input voltage and requires use with a compatible Class 2 power supply unit. Q-Tran provides options for mounting clips, mounting channels, and Q-Angle accessories to facilitate different installation methods.

COMPLIANT
1
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
.53"
.72"
2© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
METHODS OF INSTALLATION
Mounting Clip
Seamless Mounting Channels
WALL
WALL
Q-ANGLE: (Sold separately)
FLOOR
Not rated for walkover
CEILING
WSC
MC
WSC
1.38"
1.50"
2.23"
1.93"
.37”
.81”
.75”
PPS-LP-CL-2
PPS-LP-CL-96/FT
White snug clip
.81
"
2.0"
.86
"
.81"
96
" / FT
.86
"
.81"
96
" / FT
.86
"
.69"
2.0"
.69"
96" / FT
.69"
96" / FT
PPS-LP-CL-2 PPS-LP-CL-96/FT
2” PVC low profile mount channel 96”/custom length PVC low profile mount channel
MC
.51”
.27”
.12”
.77”
Magnetic clip
WSC (page 6)
MC (page 7)
PPS-LP-CL-2 (page 8)
PPS-LP-CL-96 & PPS-LP-CL-FT (page 9)
Cove, Under &
over cabinet:
Ideal for oce, retail,
hospitality, education,
laboratory, and
residential.
Shelf:
Ideal for oce, retail,
hospitality, education,
laboratory, and
residential.
Display cabinet:
Ideal for retail and
hospitality.
Signage:
Ideal for lobby, retail,
hospitality, institutional,
and transportation.
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
ATTENTION: Please read all instructions BEFORE installation
Product to be installed by a licensed electrician - Field modifications void warranty
Use only with Class 2 power supply unit — Compatible for use with Q-Tran power supplies
Surface mount or recessed in millwork
Not rated for walkover
Input Voltage: 24VDC
Diagrams for representation only and not to scale.
Mounting Method
3© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
ACCESSORIES SOLD SEPARATELY
Q-ANGLE; sold in pairs
Low profile
PVC mounting clip
.69"
2.0"
.81
"
2.0
"
.86
"
Included
• #8 flat head screw
(1 screw for every 16”)
• No wireway
SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL
PPS-LP-CL-2 PPS-LP-CL-96 PPS-LP-CL-FT
Included
• #8 flat head screw
(1 screw for every 16”)
• No wireway
Included
• #8 flat head screw
(1 screw for every 16”)
• No wireway
• Custom length
Q-ANGLE
Included
• 4 SS #6x1.25”
Flat head wood screws
• 2 SS 4-40
Flat head clip screws
• 2 SS 6-32
Fillister screws
1.38"
1.50"
2.23"
1.93"
Low profile
PVC channel Low profile
PVC channel
.81"
96" / FT
"
.81"
96" / FT
.86
"
.69"
96" / FT
.69"
96" / FT
COMPONENTS & HARDWARE
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
NOTES:
MOUNTING CLIP SEAMLESS CLIP
2 white snug clips provided per first 12”, 1 for each additional 12”.
Other mounting styles incur additional charge, see price guide for details PPS-LP-CL-2to join two fixtures together
PPS-LP-CL-96/FT to support the fixtures
PPS-LP-CL-FT is to be cut at Q-Tran to requested length
LUME-01 Profile
.53"
.72"
MOUNTING CLIP & MOUNTING CHANNEL
WSC MC
Included
• #6 Flat Screw
(one provided for
each clip)
Included
• #6 Flat Screw
(one provided for
each clip)
White snug clip Magnetic clip
(Cove use only)
.37”
.81”
.75”
.51”
.27”
.12”
.77”
4© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
CONTINUOUS WIRING CONFIGURATION OPTIONS
Review wire method to ensure clean installation prior to mounting finished fixture.
NOTE: Additional wire methods include:
S1: Connector/Wire Input only
P1: Connector/Wire Input and Output
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
LUME-01
5© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
For porous materials (Wood, Brick, Concrete etc.) apply two
layers of paint or primer to the surface. This will help create
a better bonding surface for these materials.This can be
purchased from local hardware store.
Paint or
3M
Primer 94
Wood Brick Concrete
1 layer 2 layers
Temperature and environmental concerns:
• Ideal application environment is 70-100ºF in 50% humidity
or less.
• Minimum application temperature: 50ºF
• This temperature and humidity should be maintained for
72 hours after application for maximum holding force.
50% humidity
or less
70-100ºF 72 hrs
MATERIALS SUGGESTED EPOXIES
Concrete, Stone, Cinderblock,
Metal, and Brick
Loctite Metal and
Concrete Two-Part Epoxy
ABS, Fiberglass,
Plastic, and PVC
Loctite Plastic
Two-Part Epoxy
Tile, Wood, Ceramic,
Glass, or Metal
Loctite Clear
Two-Part Epoxy
All Purpose Strong Stik
3
1 2
SURFACE MOUNTING METHOD
SURFACE PREPARATION
Using a 50/50 alcohol mix, thoroughly clean the backside of
the fixture and the surface area where fixture will be installed.
Allow 5 minutes to dry.
5 mins
50/50
alc
6© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
Determine the fixture(s) location and positioning on desired
surface; evenly distribute clips. Make any necessary
reference markings to indicate where each clip is to be
secured in place. Recommended every 12”.
Secure clips using the #6 flat head hardware provided
Ensure the screw head is flush with the clip’s base.
Snap fixture onto clips.
12
13
14
15
11
10
12"
M
a
r
k
e
r
1 2
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
SURFACE MOUNTING METHOD: WHITE SNUG CLIP
12"
NOTE: Flat head screw type is dependent on surface/application material
Alternative flat head screws may be required. Refer to the surface material
manufacturer for suggested screw type.
2 clips provided per first 12”, 1 for each additional 12”
.28"
.63"
#6x5/8" Flat head screw
3
7© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
12"
Attach clips to fixture matching magnet distances.
NOTE: Flat head screw type is dependent on surface/application material.
Alternative flat head screws may be required. Refer to the surface material
manufacturer for suggested screw type.
2
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
1
Determine the fixture(s) location and positioning on desired
surface; evenly distribute clips. Make any necessary
reference markings to indicate where each clip is to be
secured in place. Recommended every 12”.
MOUNTING METHOD: MAGNETIC CLIP
2 clips provided per first 12”, 1 for each additional 12”
Align and snap fixture to magnetic rings.
3
12
13
14
15
11
10
12"
M
a
r
k
e
r
.28"
.63"
#6x5/8" Flat head screw
8© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
Power Supply
Finished assembly for end feed mounting
1 2
SEAMLESS MOUNTING METHOD: PPS-LP-CL-2
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
Snap in 2” channel. Press fixture into mounted PPS channel.
Connects two fixtures, with no wire exit
2” low profile PVC mount channel
3
9© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-05-05-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - LUME-01
1 2
16" 16" 16"
SEAMLESS MOUNTING METHOD: PPS-LP-CL-96 / PPS-LP-CL-FT
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
The PPS-BRACKET can be field cuttable and cut to whatever
length your application requires. The PPS-BRACKET can be
installed as a full length of 96”, multiple smaller pieces, or
end to end for longer seamless runs.
Using pre-drilled pilot holes screw the #8 flat head screws to
mount the PPS-BRACKET (1 screw every 16”).
NOTE: For drywall applications mount directly into a stud.
To mount, pinch the upper half of the PPS-LP-CL-96 or
PPS-LP-CL-FT while you pivot it around one side of the
PPS-BRACKET and push-in until you hear it snap into
place. The PPS-LP-CL-96 or PPS-LP-CL-FT flexes around the
PPS-BRACKET to create a solid, and secure snap on
connection.
Using pre-drilled pilot holes, use the #8 flat head screws to
mount the PPS-BRACKET.
Support two fixtures, without built-in wireway
96” (PPS-LP-CL-96) or custom length (PPS-LP-CL-FT)low profile
PVC mount channel
#8 Flat head screw
.31
"
1.75"
.17
"
.69
"
PPS - BRACKET:
Sold in full length of 96"
or custom length (FT)
2" or more
.86"
.81"
MILLWORK
.95"
Cut out area
Millwork install
No Bracket: With Bracket:
3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Q-tran Q-TRAN LUME-01 Fully Encapsulated Flexible Fixture User manual

Type
User manual

Q-Tran Q-TRAN LUME-01 Fully Encapsulated Flexible Fixture is a versatile lighting solution suitable for various applications like offices, retail stores, and hospitality venues. This fixture can be surface-mounted or recessed in millwork and offers multiple mounting options for seamless integration. It is not rated for walkover applications. The product comes with a 24VDC input voltage and requires use with a compatible Class 2 power supply unit. Q-Tran provides options for mounting clips, mounting channels, and Q-Angle accessories to facilitate different installation methods.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI