Q-tran Q-TRAN FXT-FLEXIBLE-WAVE Flexible Square LED Fixture User manual

Type
User manual

Q-Tran Q-TRAN FXT-FLEXIBLE-WAVE Flexible Square LED Fixture is a versatile lighting solution for various applications, including office, retail, hospitality, education, laboratory, and residential settings. Its flexible design allows for seamless mounting on ceilings, walls, or under cabinets, making it ideal for cove, under and over cabinet, shelf, display cabinet, and signage installations. With multiple mounting options, including VHB tape, white snug clips, and a variety of mount channels, this fixture offers easy and secure installation.

Q-Tran Q-TRAN FXT-FLEXIBLE-WAVE Flexible Square LED Fixture is a versatile lighting solution for various applications, including office, retail, hospitality, education, laboratory, and residential settings. Its flexible design allows for seamless mounting on ceilings, walls, or under cabinets, making it ideal for cove, under and over cabinet, shelf, display cabinet, and signage installations. With multiple mounting options, including VHB tape, white snug clips, and a variety of mount channels, this fixture offers easy and secure installation.

COMPLIANT
1
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
.38"
.38"
2© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
METHODS OF INSTALLATION
.47”
.56”
96”/FT
.47”
.56”
96”/FT
.47”
.56”
2.00”
.46"
96" / FT
.94"
96
" / FT
.56"
.46"
96" / FT
.94"
96
" / FT
.56"
.46"
2.0"
.94"
2.0
"
.56"
Mounting Clip
Seamless Mounting Channel
WALL
WALL
Q-ANGLE: (Sold separately)
FLOOR
Not rated for walkover
CEILING
WSC
WSC
1.38"
1.50"
2.23"
1.93"
PPS-2
PPS-96/FT
PPS-LP-2
PPS-LP-96/FT
PPS-2 PPS-96/FT
PPS-LP-2 PPS-LP-96/FT
White snug clip
2” PVC mount channel
2” PVC low profile mount channel 96”/custom length PVC low profile mount channel
96”/custom length PVC mount channel
VHB Tape
Sold separately
Adhesive Mount
.25”
.44”
.50”
VHB (page 6)
WSC (page 7)
PPS-2 (page 8)
PPS-LP-2 (page 9)
PPS-96 & PPS-FT (page 10)
PPS-LP-96 & PPS-LP-FT (page 11)
Cove, Under &
over cabinet:
Ideal for oce, retail,
hospitality, education,
laboratory, and
residential.
Shelf:
Ideal for oce, retail,
hospitality, education,
laboratory, and
residential.
Display cabinet:
Ideal for retail and
hospitality.
Signage:
Ideal for lobby, retail,
hospitality, institutional,
and transportation.
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
ATTENTION: Please read all instructions BEFORE installation
Product to be installed by a licensed electrician - Field modifications void warranty
Use only with Class 2 power supply unit — Compatible for use with Q-Tran power supplies
Surface mount or recessed in millwork
Not rated for walkover
Input Voltage: 24VDC
Diagrams for representation only and not to scale.
Mounting Method
3© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
.38"
.38"
SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL
PPS-LP-2 PPS-LP-96 PPS-LP-FT
COMPONENTS & HARDWARE
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
NOTES:
MOUNTING CLIP SEAMLESS CLIP
2 white snug clips provided per first 12”, 1 for each additional 12”.
Other mounting styles incur additional charge, see price guide for details PPS-2 & PPS-LP-2 to join two fixtures together
PPS-96/FT & PPS-LP-96/FT to support the fixtures
PPS-FT is to be cut at Q-Tran to requested length
WAVE Profile
MOUNTING CLIP & MOUNTING
CHANNEL ADHESIVE SOLD SEPARATELY
WSC VHB TAPE
Included
• #4 Flat Screw
(one provided for
each clip)
White snug clip TAPE-VHB-IP20
.25”
.44”
.50”
SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL
PPS-2 PPS-96 PPS-FT
Included
• #6 flat head screw
(1 screw for every 16”)
• Built in wireway
Included
• #6 flat head screw
(1 screw for every 16”)
• Built in wireway
• Custom length
Included
• #6 flat head screw
(1 screw for every 16”)
• Built in wireway
Included
• #6 flat head screw
(1 screw for every 16”)
• No wireway
PVC mounting clip PVC channelPVC channel
Low profile
PVC mounting clip
.46
"
2.0"
.94
"
2.0"
.56"
.94
"
96
" / FT
.56"
.94
"
96
" / FT
.56"
.46
"
96" / FT
.46
"
96" / FT
.47”
.56”
2.00”
Included
• #6 flat head screw
(1 screw for every 16”)
• No wireway
Included
• #6 flat head screw
(1 screw for every 16”)
• No wireway
• Custom length
Q-ANGLE
Included
• 4 SS #6x1.25”
Flat head wood screws
• 2 SS 4-40
Flat head clip screws
• 2 SS 6-32
Fillister screws
ACCESSORIES SOLD SEPARATELY
Q-ANGLE; sold in pairs
1.38"
1.50"
2.23"
1.93"
Low profile
PVC channel Low profile
PVC channel
.47”
.56”
96”/FT
.47”
.56”
96”/FT
.63"
.38"
WAVE Profile
(Seamless BW)
.63"
.38"
WAVE Profile
(Seamless BRL)
.64"
.40"
WAVE Profile
(Seamless SW)
.64"
.40"
WAVE Profile
(Seamless DW)
.77"
.57"
WAVE Profile
(Seamless RGB)
4© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
CONTINUOUS WIRING CONFIGURATION OPTIONS
Review wire method to ensure clean installation prior to mounting finished fixture.
NOTE: Additional wire methods include:
S1, S5: Connector/Wire Input only
P1, P5: Connector/Wire Input and Output
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
WAVE
5© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
For porous materials (Wood, Brick, Concrete etc.) apply two
layers of paint or primer to the surface. This will help create
a better bonding surface for these materials. This can be
purchased from local hardware store.
Temperature and environmental concerns:
• Ideal application environment is 70-100ºF in 50% humidity
or less.
• Minimum application temperature: 50ºF
• This temperature and humidity should be maintained for
72 hours after application for maximum holding force.
50% humidity
or less
70-100ºF 72 hrs
MATERIALS SUGGESTED EPOXIES
Concrete, Stone, Cinderblock,
Metal, and Brick
Loctite Metal and
Concrete Two-Part Epoxy
ABS, Fiberglass,
Plastic, and PVC
Loctite Plastic
Two-Part Epoxy
Tile, Wood, Ceramic,
Glass, or Metal
Loctite Clear
Two-Part Epoxy
All Purpose Strong Stik
3
1 2
SURFACE MOUNTING METHOD
SURFACE PREPARATION
Using a 50/50 alcohol mix, thoroughly clean the backside of
the fixture and the surface area where fixture will be installed.
Allow 5 minutes to dry.
5 mins
50/50
alc
6
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
METHODS &
INSTALLATIONS
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
a. To adhere the VHB adhesive, peel the white film back while
evenly applying the tape to the mounting side of the
extrusion. The red side should be visible.
b. Remove the red film and position extrusion in place
according to your previous reference marking(s).
Determine the fixture(s) location and positioning on desired
surface before adhering fixture to surface. Make any
necessary reference markings to indicate extrusion placement.
Remove protective film from the surface of the extrusion’s lens.
NOTES: EPOXY ALTERNATIVE: For improved bonding strength, apply a small amount of epoxy at each end. Refer to table on for suggested
epoxies. These can be purchased at a local hardware store. Please follow all manufacturer instructions for suggested epoxy.
page 5
Length as needed
a.
b.
SURFACE MOUNTING METHOD: VHB ADHESIVE MOUNT
BEFORE installation, the surface must be thoroughly cleaned and dried for maximum bond strength. (Page 5)
30
31
14
15
29
28
Length as needed
M
a
r
k
e
r
1 2
3
7© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
.21
"
.625"
Determine the fixture(s) location and positioning on desired
surface; evenly distribute clips. Make any necessary
reference markings to indicate where each clip is to be
secured in place. Recommended every 12”.
Secure clips using the #4 flat head hardware provided
Ensure the screw head is flush with the clip’s base.
Snap fixture onto clips.
12
13
14
15
11
10
12"
M
a
r
k
e
r
1 2
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
SURFACE MOUNTING METHOD: WHITE SNUG CLIP
12"
NOTE: Flat head screw type is dependent on surface/application material
Alternative flat head screws may be required. Refer to the surface material
manufacturer for suggested screw type.
2 clips provided per first 12”, 1 for each additional 12”
#4x5/8" Flat head screw
3
8© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
Power Supply
Finished assembly for seamless feed mounting
1 2
SEAMLESS MOUNTING METHOD: PPS-2
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
Press both fixtures into PPS channel. Snap fixture into mounted PPS channel when wire will exit into
conduit do not install bracket.
Connects two seamless fixtures, with or without wire exit
2” PVC mount channel
Built in wireway
3
9© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
Power Supply
Finished assembly for end feed mounting
1 2
SEAMLESS MOUNTING METHOD: PPS-LP-2
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
Snap in 2” channel. Press fixture into mounted PPS channel.
Connects two fixtures, with no wire exit
2” low profile PVC mount channel
3
10© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
1 2
16" 16" 16"
SEAMLESS MOUNTING METHOD: PPS-96 / PPS-FT
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
The PPS-BRACKET can be field cuttable and cut to whatever
length your application requires. The PPS-BRACKET can be
installed as a full length of 96”, multiple smaller pieces, or
end to end for longer seamless runs.
Using pre-drilled pilot holes screw the #6 flat head screws to
mount the PPS-BRACKET (1 screw every 16”).
NOTE: For drywall applications mount directly into a stud.
To mount, pinch the upper half of the PPS-96 or PPS-FT
while you pivot it around one side of the PPS-BRACKET and
push-in until you hear it snap into place. The PPS-96 or
PPS-FT flexes around the PPS-BRACKET to create a solid,
and secure snap on connection.
Using pre-drilled pilot holes, use the #6 flat head screws to
mount the PPS-BRACKET.
Support two seamless fixtures, with or without wire exit
96” (PPS-96) or custom length (PPS-FT)
Built in wireway
.17
"
.46
"
PPS - BRACKET:
Sold in full length of 96"
or custom length (FT)
MILLWORK
.65"
.95"
Cut out area
Millwork install
The PPS-BRACKET
allows you to create
a wire way under the
PPS channel
without any screws
interfering
Built in wireway:
2" or more
3
#6 Flat head screw
.26
"
1"
11© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-07-13-23
INSTALLATION INSTRUCTIONS
FLEXIBLE FIXTURES - WAVE
1 2
16" 16" 16"
SEAMLESS MOUNTING METHOD: PPS-LP-96 / PPS-LP-FT
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
WIRING OPTIONS
The PPS-LP-96 or PPS-LP-FT can be field cuttable and cut
to whatever length your application requires. The PPS-96
or PPS-FT can be installed as a full length of 96”, multiple
smaller pieces, or end to end for longer seamless runs.
Drill holes (1 hole/screw every 16”) into the PPS-LP
Snap fixture into PPS-LP.
Using pre-drilled holes, use the #6 flat head screws to mount
the PPS-LP.
NOTE: For drywall applications mount directly into a stud.
Support two fixtures, without built-in wireway
96” (PPS-LP-96) or custom length (PPS-LP-FT)low profile
PVC mount channel
#6 Flat head screw
.26
"
1"
.48"
MILLWORK
.59"
Cut out area
Millwork install:
3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Q-tran Q-TRAN FXT-FLEXIBLE-WAVE Flexible Square LED Fixture User manual

Type
User manual

Q-Tran Q-TRAN FXT-FLEXIBLE-WAVE Flexible Square LED Fixture is a versatile lighting solution for various applications, including office, retail, hospitality, education, laboratory, and residential settings. Its flexible design allows for seamless mounting on ceilings, walls, or under cabinets, making it ideal for cove, under and over cabinet, shelf, display cabinet, and signage installations. With multiple mounting options, including VHB tape, white snug clips, and a variety of mount channels, this fixture offers easy and secure installation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI