Q-tran Q-HEX MINI is a power supply unit designed for outdoor use, specifically for powering LED lights. It features a resetable secondary circuit breaker with a watertight boot, ensuring reliable operation and protection against electrical faults. The Q-HEX MINI can handle both AC and DC inputs, making it compatible with a wide range of lighting systems. Additionally, its compact design allows for easy installation in tight spaces, such as junction boxes or underground enclosures.

Q-tran Q-HEX MINI is a power supply unit designed for outdoor use, specifically for powering LED lights. It features a resetable secondary circuit breaker with a watertight boot, ensuring reliable operation and protection against electrical faults. The Q-HEX MINI can handle both AC and DC inputs, making it compatible with a wide range of lighting systems. Additionally, its compact design allows for easy installation in tight spaces, such as junction boxes or underground enclosures.

© 2015, Q-Tran Inc. 155 Hill St. Milford, CT 06460.All rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.
com - www.q-tran.com
Q-TRIX R50 & Q-HEX MINI
INSTALLATION INSTRUCTION
Cautions “ The Main Secondary wiring is intended for shallow burial - Less than 6 inches (152mm)
unless Q-Tran direct burial Q-Wire and Q-Clik are used " To purchase additional Q-Wire and
Q-Clik Connectors visit our website (q-tran.com) or contact your local Q-Tran representative. The
Power Unit is not to be used within 10 Feet (3.05 m) of a pool or spa.
CAUTION
Q-TRIX R50
Q-HEX Mini
HIGH IMPACT
Top Cap
Primary wires
Secondary wires
Resetable secondary
CIRCUIT BREAKER
with water tight boot
Label
Sec. WIRE COMPARTMENT
(wire leads held in an individual Secure Tube)
HIGH IMPACT BOTTOM COVER
Q-HEX mini (Power Supply) Details
1/2” NPT Threaded Cap
1/2” NPT THREADED POST
(For mounting a path light or Accent light fixture)
HIGH IMPACT Housing
Planting Stakes
(Secures unit to the ground 3x)
Housing GASKET
DRILL GUIDE - Drill and attach fittings
(Q-Click 1/2” & 3/4” fittings permitted)
HIGH IMPACT Door
FIELD WRITING TRACK
(For unit locating)
Q-TRIX (R) Remote Box Details
1/4-20 Bolts (3x)
Nut Holder
1/4-20 Nuts
A
C
B
D
E
F
H
G
I
J
K
A
B
C
D
E
F
GG
E
E:
A:
B:
C:
D:
F:
G:
A:
B:
C:
D:
E:
F:
G:
H:
I:
J:
K:
1
2
Q-TRIX R-50 (LOAD DISTRIBUTION REMOTE SPLICE BOX)
Q-TRIX R50 - MATRIX
Q-TRIX Direct Burial Design configuration
(1) Feed from Q-TRIX B160 unit to Q-TRIX R50 (2) Feed from Q-TRIX B160 unit to Q-TRIX R50 (3) Q-TRIX B160 to B160 to R-50 remote boxes
Pathway
example:
Q-HEX Mini installation
(Q-Hex Mini & Q-Trix R50 combination)
SPLICE J-BOX
3/4” KO 3x
Bottom
1” KO 1x
1/2” KO 3x
WALL MOUNT PLATE
Q-TRIX WALL Installation
(Optional wall plate sold seperately)
(Use water tight connectors
Ex: Q-Clik MST/NPT connectors.
Connectors sold seperately)
1 2
2 3
x
x
xx
Q-TRIX R50 WITHOUT Q-HEX MINI
Do not use KO (Knock Outs)marked
with X when installing the Q-HEX
MINI with the Q-TRIX R50.
Q-TRIX-R50 with Q-HEX-MINI
This unit can be used as a splice box
1
2
3
3
Q-TRIX R50, Q-HEX mini
1
Q-Clik MST
Q-Clik NPT
Bottom Sides
or
A Install
SStakes (3X)
B Install
connectors
Q-Hex Mini install orientation:
X
X
XX
EXCAVATE (DIG HOLE)
INSTALL CONNECTORS & STAKES
LOWER Q-HEX mini INTO Q-TRIX R50
Dig 10" x 10" x 12" hole that Q-Trix R50 housing will fit inside
as shown.
2
KNOCKOUT OR DRILL HOLES
RUN FIELD WIRES TO HOUSING
PREPARE Q-HEX mini WIRE
Drill knock out holes for Wire Connectors.Example: Q-Clik
connectors.
Optional 1/2"
MST KO
3/4" NPT
Connector
*
Use only these Drill sizes for side Holes: 7/8 for 1/2” KO and 1 1/8 for 3/4” KO
NOTE: Drill only TOP KO holes of Q-Trix R50 housing,or useonly outer
Knockouts on the bottom when installing Q-HEX mini power supply unit.
Maximum 3x Q-Clik connectors can be installed at the bottom or 3x on either
side or the Housing. 3xconnectors of 1/2” or 3/4” on each side. Use 3/4”
connector on bottom. (Q-CLIK SOLD SEPARATELY)
3 4
65
NOTE: Use Q-wire & Q-Clik
for water tight installation (Q-Wire
& Q-Clik sold seperately)
6"
6"
Field wires
*Pull maximum of 6” of primary and
Secondary wires into Q-Trix R50 housing.
CAUTION
See Front Page
6"
6"
Wire Corner
Breaker head corner
Field wires
Primary wiring side
Yellow
Blue
Green
White
Black
Yellow
Blue
Green
White
Black
Understand the following highlighted wires
NOTE: Strip ends for wire nut connection
INPUT OUTPUT
Transformer
Primary wires
Green - Ground
White - Neutral
Black - Tap 1
LED DRIVER
INPUT
Primary wires
Vac IN
Vac IN
LED DRIVER
DC OUT PUT
Secondary wires
Positive +
Negative -
ACDC
AB
Transformer
Secondary wires
12 v / 24v
common
*Circuit breaker
*Secondary Circuit breaker factory installed is optional requested when placeing order
12"
SIDE VIEW
(Hole Depth)
10"
10"
TOP VIEW
(Hole Length & Width)
HOUSING WALL
RUBBER
INSERT
CLIK
RING
MACHINE SCREW THREAD
(MST) BASE
WASHER 1 WASHER 2
WING NUT
NUT
4
Q-TRIX R50, Q-HEX mini
7
8
9
10
CONNECT WIRES CONNECT WIRES
Use Water tight silicone filled wire nuts to connect all wires in the Q-Trix Unit
( wire nuts not provided ).
Use Q-Trix R-50 remote box for additional wire splicing or power distribution.
( Additional Q-Trix R-50 remote box sold seperately ).
Connect INPUT load to Primary
white / black and green wire
Connect OUTPUT load to
secondary 12v or 24v wire and
common wire.
Connect INPUT load to Primary
Blue wires VAC
Connect OUTPUT load to
secondary +Yellow / - Black wire
AC DC
AC Installation Displayed CAUTION
See Front Page
PREPARE UNIT TO BE BURIED
Use provided wire ties to
manage excess
AC Installation displayed
Tuck connected wire nuts in
the corner as shown
WireTies (10x)
Cover Housing and tightened (3x) 1/4-20
stainless steel Door Bolts by alternating bolt
turns. Tighten bolts at a Maximum torque of 25” lbs.
BURY Q-TRIX WITH 2” TOP EXPOSED
OPTIONS
OPTIONAL FIXTURE INSTALLA-
TION ON Q-TRIX UNIT
Remove cap and
expose 1/2” NPT
threads and knockout
center K.O to install Path light,
or accent light. Important; squeeze
silicone into threads before mounting
fixture. (See Diagram C)
Q-TRIX WALL Plate
(Wall plate sold separately)
Allows unit to be surface
mounted. Indoor or Outdoor.
Install wall plate with Stainless
Steel Pan Head 1/4-20 x 5/16”
screw bolts (screws not
provided)
Q-TRIX R50 SPLICE BOX
Diagram A Diagram B Diagram C
Q-Trix R50 Housing
can be used for wire
splicing and power
distribution(Q-clik 1/2”
& 3/4”NPT or MST
connectors can be
used
)
Q-TRIX FIXTURE MOUNT
1/2” NPT
threaded Door
allows fixture to
be mounted on
Q-Trix unit.
12"
SIDE VIEW
(Hole Depth)
10"
10"
TOP VIEW
(Hole Length & Width)
© 2015, Q-Tran Inc. 155 Hill St. Milford, CT 06460.All rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: [email protected] - www.q-tran.com
5
4
10"
10"
12"
TOP VIEW
(Hole Length & Width)
SIDE VIEW
(Hole Depth)
Bury Q-TrixR-50 in
a 10x10x12 inch
dugged up hole.
Bury Q-Trix R-50with 2”
top exposed
Remove cap and expose
1/2” NPT threads and
knockoutcenter K.O to
install Path Light,or Accent
Light. Important; squeeze
silicone into threads before
mounting fixture. (See
Diagram A & B)
OPTIONAL FIXTURE INSTALLATION
ON Q-TRIX R-50 JUNCTION BOX
Q-Trix R-50 FIXTURE MOUNT
Diagram BDiagram A
Q-TRIX R-50 DIRECT BURIAL SPLICE BOX
Q-Trix R-50 junction box allows for multiple load distribution
from Q-Trix B160 or B200 unit and can stand alone as a Direct
Burial junction box.
Pathway
example:
© 2015, Q-Tran Inc. 155 Hill St. Milford, CT 06460.All rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: [email protected] - www.q-tran.com
6
Q-TRIX-R50-WP
Wall Mount Plate Installation
1
INSTRUCTIONS
Cut diagram on the left to trace
the location of the Lag Bolt
for wall mounting.
AA
LARGE PLATE
AA
SMALL PLATE
B
B
Full Scale Template:
Cut Template to use on wall
*Lag Bolts must be mounted to wall studs.
(2X) 1/4 x 1.5"
Hex Lag Bolt
(4X) 1/4-20 x 3/8"
Pan Phillips
Machine Screw
A
B
PARTS INCLUDED
B
(4X) 1/4-20 x 3/8"
Pan Phillips
Machine Screw
A
(2X) 1/4 x 1.5"
Hex Lag Bolt
B
© 2015, Q-Tran Inc. 155 Hill St. Milford, CT 06460.All rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: [email protected] - www.q-tran.com
7
2Screw large and small plates
to the bottom of the Q-Trix-R50
with Machine Screws.
B
3Install Lag Bolt screw into wall
where the unit will reside. Then
slide the key hole unit onto the
screw. Lastly install final Lag
Bolt at the bottom of the plate
LARGE PLATE
SMALL PLATE
A
B
WALL
WALL
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Q-tran Q-HEX MINI Installation guide

Type
Installation guide

Q-tran Q-HEX MINI is a power supply unit designed for outdoor use, specifically for powering LED lights. It features a resetable secondary circuit breaker with a watertight boot, ensuring reliable operation and protection against electrical faults. The Q-HEX MINI can handle both AC and DC inputs, making it compatible with a wide range of lighting systems. Additionally, its compact design allows for easy installation in tight spaces, such as junction boxes or underground enclosures.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI