User Manual GL1020FTE Avionic Logger Start-Up/Commissioning
© Vector Informatik GmbH Version 1.5 - 17 -
3.3 Quick Start
Quick start Follow the instructions below to configure the logger, start logging and read out
Configuration
1. Start the program Vector Logger Configurator.
2. Open a new configuration via the menu File|New Project…. Select in the
displayed dialog the logger type GL1020FTE.
3. Select suitable baud rates for each CAN channel (Hardware|CAN Channels).
4. Select the timeout to sleep mode (Hardware|Settings).
5. Configure the logger for a permanent logging of all data from switching on to
switching off of the logger by activating the Permanent long-term logging option
in Logging|Triggers.
6. Connect the logger to the PC via USB cable. If the logger is not automatically
detected, press <F5> to refresh the display of connected logger devices.
7. Download the configuration via menu Configuration|Write to Device….
8. Set the real-time clock via menu Device|Set Real-Time Clock… (recommended
before first logging). Afterwards the logger is automatically switched off.
9. Disconnect the logger from the PC.
Recording
10. Connect the logger to the CAN bus and power supply via the DSUB25 connector
of your test system or aircraft. Switch power on via connecting cable on DSUB25.
The logger has to be supplied by 28 VDC also via this cable. Make sure that the
logger and your system is supplied by the same voltage supply. Otherwise the
ground pins has to be connected.
Note: Usage with one ECU or CANoe as test system
Make sure that at least 2 real ECUs or 2 simulated CAN channels (CANoe) are
connected to the logger to obtain the acknowledge on the CAN bus. Make sure
that the CAN bus is terminated by 2x 120 Ω.
Note: Usage with original target system
It is preconditioned that the target system contains at least 2 ECUs due to the
acknowledge on the CAN bus as well as the required termination. Therefore the
logger can be connected without additional precautions.
11. After power on logging is started. LED1 flashes permanently (This is a standard
setting for new configurations. It can be configured otherwise).
12. Stop logging either by switching off CAN and wait until the logger goes to sleep
mode (LED1 must be off) or by connecting the logger via USB to a Laptop (USB