Vector CANcaseXL log User manual

Type
User manual

This manual is also suitable for

Manual
CANcaseXL
CANcaseXL log
Version 4.0
English
Imprint
Vector Informatik GmbH
Ingersheimer Straße 24
D-70499 Stuttgart
The information and data given in this user manual can be changed without prior notice. No part of this manual may be reproduced in
any form or by any means without the written permission of the publisher, regardless of which method or which instruments, electronic
or mechanical, are used. All technical information, drafts, etc. are liable to law of copyright protection.
© Copyright 2009, Vector Informatik GmbH
A
ll rights reserved.
A
rt. 80082
Manual Table of contents
© Vector Informatik GmbH Version 4.0 - I -
Table of contents
1 Introduction 3
1.1 About this user manual 4
1.1.1 Access helps and conventions 4
1.1.2 Certification 5
1.1.3 Warranty 5
1.1.4 Support 5
1.1.5 Registered trademarks 5
2 CANcaseXL and CANcaseXL log 7
2.1 Introduction 8
2.2 Connections 8
2.3 LED Display 10
2.4 Additional features on CANcaseXL log 10
2.4.1 Operating modes 10
2.4.2 Additional LEDs 11
2.4.3 Piezo buzzer 12
2.4.4 Memory card 12
2.4.5 Battery 12
2.4.6 CANcaseXL log Flowchart 13
2.5 Replacing Piggybacks 14
2.6 Technical Data 15
3 Appendix A: Address table 17
Manual Introduction
© Vector Informatik GmbH Version 4.0 - 3 -
1 Introduction
In this chapter you find the following information:
1.1 About this user manual page 4
Access helps and conventions
Certification
Warranty
Support
Registered trademarks
Introduction Manual
- 4 - Version 4.0 © Vector Informatik GmbH
1.1 About this user manual
1.1.1 Access helps and conventions
To find information
quickly
The user manual provides you the following access helps:
¼ At the beginning of each chapter you will find a summary of the contents,
¼ In the header you can see in which chapter and paragraph you are ((situated)).
Conventions In the two following charts you will find the conventions used in the user manual
regarding utilized spellings and symbols.
Style Utilization
Blocks, surface elements, window- and dialog names of the
software. Accentuation of warnings and advices.
bold
[OK] Push buttons in brackets
File | Save Notation for menus and menu entries
Windows Legally protected proper names and side notes.
Source code
File name and source code.
Hyperlink Hyperlinks and references.
<STRG>+<S> Notation for shortcuts.
Symbol Utilization
This symbol calls your attention to warnings.
Here you can find additional information.
Here is an example that has been prepared for you.
Step-by-step instructions provide assistance at these points.
Instructions on editing files are found at these points.
This symbol warns you not to edit the specified file.
Manual Introduction
© Vector Informatik GmbH Version 4.0 - 5 -
1.1.2 Certification
Certified Quality
Management System
Vector Informatik GmbH has ISO 9001:2000 certification. The ISO standard is a
globally recognized standard.
1.1.3 Warranty
Restriction of
warranty
We reserve the right to change the contents of the documentation and the software
without notice. Vector Informatik GmbH assumes no liability for correct contents or
damages which are resulted from the usage of the user manual. We are grateful for
references to mistakes or for suggestions for improvement to be able to offer you
even more efficient products in the future.
1.1.4 Support
You need support? You can get through to our support at the phone number
+49 711 80670-200 or by fax
+49 711 80670-111
E-Mail: support@vector-informatik.de
1.1.5 Registered trademarks
Registered
trademarks
All trademarks mentioned in this user manual and if necessary third party registered
are absolutely subject to the conditions of each valid label right and the rights of
particular registered proprietor. All trademarks, trade names or company names are
or can be trademarks or registered trademarks of their particular proprietors. All rights
which are not expressly allowed, are reserved. If an explicit label of trademarks,
which are used in this user manual, fails, should not mean that a name is free of third
party rights.
¼
Windows, Windows 2000, Windows XP, Windows Vista are trademarks of the
Microsoft Corporation.
Manual CANcaseXL and CANcaseXL log
2 CANcaseXL and CANcaseXL log
In this chapter you find the following information:
2.1 Introduction page 8
2.2 Connections page 8
2.3 LED Display page 10
2.4 Additional features on CANcaseXL log page 10
Operating modes
Additional LEDs
Piezo buzzer
Memory card
Battery
CANcaseXL log Flowchart
2.5 Replacing Piggybacks page 14
2.6 Technical Data page 15
© Vector Informatik GmbH Version 4.0 - 7 -
CANcaseXL and CANcaseXL log Manual
- 8 - Version 4.0 © Vector Informatik GmbH
2.1 Introduction
CANcaseXL The CANcaseXL is a USB interface with a powerful 32-bit 64MHz microcontroller
from ATMEL with ARM7 Core and two SJA1000 CAN controllers from Philips. It can
process CAN messages with either 11-bit or 29-bit identifiers. Moreover, it is possible
to receive and analyze Remote Frames without any limitations. The CANcaseXL is
also capable of generating and detecting Error frames on the bus.
CANcaseXL log The CANcaseXL log offers the same features as the CANcaseXL, but it can also be
used as a data logger for CAN and LIN messages. The logged data are saved on
industrial-grade SD cards. For further information please refer to section 2.4.4
Memory card.
With the Vector Hardware Configuration -Tool (Start | Settings | Control Panel |
Vector Hardware) the CANcaseXL/log can be configured, further on it displays
information about the channels. Further details can be found in the installation
instructions.
Configuration
Bus types Various transceivers are available to interface the CANcaseXL/log to a particular type
of bus. These CAN and LIN transceivers can be purchased as plug-in boards
(Piggybacks) and can be mounted inside the CANcaseXL/log. For information on
installing transceivers please refer to section 2.5 Replacing Piggybacks. A list of
available CANpiggies and LINpiggies can be found in the accessories manual:
\Drivers\XL_Family_Accessories.pdf
2.2 Connections
General information The CANcaseXL has the following connectors:
¼ USB connector for the usage with PC in Interface Mode
¼ Binder connector for power supply, synchronization and trigger
¼ Two D-SUB9 connectors for independent CAN/LIN operation
Furthermore the CANcaseXL log has a:
¼ SD card slot for data logging
Info: CANpiggies will be deactivated when SD card is accessed in Interface
mode.
Info: The CANcaseXL log is delivered with a 2GB SD card.
USB connector The CANcaseXL/log is connected to an unused PC-USB port via a USB cable which
also supplies voltage to the CANcaseXL/log in Interface Mode.
Binder connector If the USB port is not capable of supplying the required 500 mA operating current, the
CANcaseXL/log may optionally be supplied by an external voltage source. The
CANcaseXL/log provides a 3-pin Binder connector for this purpose. Available power
supplies can be found the accessories manual on the installations CD.
Manual CANcaseXL and CANcaseXL log
© Vector Informatik GmbH Version 4.0 - 9 -
Pin assignment of
Binder connector
The following table describes the pin assignment of the Binder connector.
Pin Assignment
1
3
2
1 Voltage supply 7 V…33 V (recommended 12 V)
2 Synchronization line/external trigger input
3 Ground
Synchronization by
Binder connector
In Interface Mode the CANcaseXL/log outputs the time synchronization signal at pin 2
of the 3-pin Binder connector. You can connect devices of the Vector XL product line
with the SYNCcableXL (see accessories manual) to this pin.
Software/hardware
synchronization
Time stamps, which are created during a measurement by devices of the XL Family,
can be synchronized by software or hardware.
The software synchronization is driver-based and available for all applications without
any restrictions. This kind of synchronization can be switched on in
Vector Hardware
Config | General information | Settings | Software time synchronization
. The
accuracy of the time stamp correction depends on the device and is typically 50 µs.
The hardware synchronization of maximum four devices is realized by the SYNC-
cable (see description below) and has to be supported by the application. The
accuracy of the time stamp correction depends on the application and is typically
1 µs.
Functionality of
hardware
synchronization
The devices to be synchronized must be interconnected by a party line (two-wire bus;
signals: SYNC and GND).
At each High-Low edge of the sync line the Vector Interface generates a time stamp
that is provided to the application via the driver. This allows the application to
synchronize the time stamps of different devices to a common time base.
The synchronization edges can be generated by the devices of the XL product line.
Info: Time synchronization must be supported by the application. For further infor-
mation please refer to the relevant manual. Please note that the time synchronization
of the driver must be disabled, when multiple devices of the XL Family are operated
on a PC and interconnected via the synchronization line (see
Vector Hardware
Config | General information | Settings | Software time synchronization)
.
External trigger by
Binder connector
In
Logging Mode pin 2 of the 3-pin Binder connector acts as a trigger input. You can
initiate triggers by pulling down pin 2 to GND. The trigger input is low active, i.e. a
trigger occurs by a falling edge.
Warning: The external trigger input is designed for 5 V (TTL) and must not be tied to
12 V!
D-SUB9 connector
for CAN/LIN
The CANcaseXL/log is connected to the CAN or LIN bus (Channel1 and Channel2)
via a 9-pin D-SUB socket. The pin assignment can be found in the accessories
manual.
CANcaseXL and CANcaseXL log Manual
- 10 - Version 4.0 © Vector Informatik GmbH
2.3 LED Display
LED display The CANcaseXL/log has for each channel (Channel1 and Channel2) three LEDs. The
LEDs indicate the direction of the message and any Error frame that occur:
Rx Tx Err Meaning
(( )) - -
Active when messages are being received.
- (( )) -
Active when messages are being sent.
- - (( ))
Active when error events occur on the bus.
Only in Logger Mode:
Blinking LED means that the related channel
is not „on bus“.
(( )) : Blinking or flashing LED.
2.4 Additional features on CANcaseXL log
2.4.1 Operating modes
Operating modes of
CANcaseXL log
The CANcaseXL log supports two operating modes, which are switched by using the
USB connection and power supply respectively:
USB connection Req. ext. voltage supply Mode
Interface /
Logger configuration
optional
yes
yes Logger
no
Interface Mode
Interface Mode In
the CANcaseXL log operates as usual CAN/LIN interface between
a PC and the bus. Messages can be received and sent over both channels with
suitable tools equal to the CANcaseXL.
Logger Mode The
Logger Mode enables the PC independent usage of the CANcaseXL log and
allows the logging of CAN and LIN events. For this purpose the CANcaseXL log must
be unplugged from the USB connector of the PC. The voltage supply is done
externally by the Binder connector.
Note: Logger Mode configuration For the the additional tool XL log Config is
available (see manual on the installation CD under \Drivers\CANcaseXL
\Tools\XL_log_Config_UsersGuide.pdf
).
Warning: During logging the CANcaseXL log may not be connected to the PC via the
USB cable, since the Logger Mode would otherwise be exited! However the
CANcaseXL log must be in the Interface Mode to configure the
LoggerMode.
Manual CANcaseXL and CANcaseXL log
© Vector Informatik GmbH Version 4.0 - 11 -
2.4.2 Additional LEDs
Additional LEDs on
CANcaseXL log
The CANcaseXL log contains beside the LEDs Tx, Rx and Err the LEDs Status and
Data with the following meaning:
Status Data Meaning
off off
Device is not operating.
Device is in Interface Mode without SD card.
green * Device is in Interface Mode with a valid SD card.
red * Device is in Interface Mode with an invalid SD card.
orange orange Device is booting in Logger Mode.
green off Device is waiting for a SD card.
green (( green )) Device is accessing the SD card.
((green)) *
Device is ready for logging.
Device is waiting for trigger.
((red)) off Device reports an error and stops logging.
(( orange )) *
Warning: SD card contains less than 10% of free space.
Logging is not stopped.
* (( orange ))
Warning: Critical data rate, but messages are not lost.
Logging is not stopped. LED state will change when
critical data rate decreases.
* (( red ))
Error: To high data rate, messages are lost. Logging is
not stopped but LED state will not change till device is
rebooted.
* : Alternating state of the LED, depending on data transmission.
(( )) : Blinking or flashing LED.
CANcaseXL and CANcaseXL log Manual
- 12 - Version 4.0 © Vector Informatik GmbH
2.4.3 Piezo buzzer
Trigger event signals The CANcaseXL log has a piezo buzzer that acoustically alerts the user to internal
trigger events. Triggers may be defined using the
XL log Config configuration tool
(see installation CD
\Drivers\CANcaseXL\Tools\XL_log_Config_Users
Guide.pdf
).
2.4.4 Memory card
Inserting and
removing of SD card
The CANcaseXL log has a push-and-pull card holder in which the SD card is inserted
and removed. To insert a SD card push it until it latches in place securely. To remove
the SD card push it into the holder slot a little bit until it unlatches then let it go and it
will spring out of its latched position.
Warning: Do not pull the SD card from the card holder forcefully, since this could
cause mechanical damage!
Formatting SD card Before using the SD card it has to be formatted with the configuration tool
XL log
Config
, see manual \Drivers\CANcaseXL\Tools\XL_log_Config_Users
Guide.pdf
.
Memory
requirements
A single CAN message needs up to 20 byte, a single LIN message needs up to 108
bytes on the memory card.
CardFix Kit The standard delivery of the CANcaseXL log allows the user to insert and remove the
SD card from outside. In some situations, e.g. to prevent thefts, the inserted SD card
shall not be removable. The
CardFix Kit is a good protection, because the back side
plate with the SD card slot is replaced by a closed plate. Thus the SD card cannot be
removed so easily anymore. The
CardFix Kit can be ordered at Vector (article number
07132).
Warning: The CANcaseXL log must be opened for this modification! A detailed
instruction is delivered with the kit. However, the modification of your CANcaseXL log
can be done by our service.
2.4.5 Battery
Lifetime The CANcaseXL log is supplied with a lithium battery that has a typical durability of 5
years. It is responsible for correct timing of the integrated clock.
Manual CANcaseXL and CANcaseXL log
© Vector Informatik GmbH Version 4.0 - 13 -
2.4.6 CANcaseXL log Flowchart
s
t
a
r
t
u
p
U
S
B
c
o
n
n
c
t
e
d
?
b
o
o
t
L
o
g
g
e
r
m
o
d
e
w
a
it
f
o
r
c
a
r
d
S
D
c
a
r
d
a
c
c
e
s
s
e
r
r
o
r
lo
g
g
e
r
s
t
o
p
p
e
d
s
u
c
c
e
s
s
?
S
D
c
a
r
d
r
e
m
o
v
e
d
?
r
e
a
d
y
w
a
it
f
o
r
t
r
ig
g
e
r
lo
g
g
in
g
C
A
N
c
a
s
e
X
L
I
n
t
e
r
f
a
c
e
m
o
d
e
m
e
s
s
a
g
e
lo
s
t
?
d
a
t
a
r
a
t
e
e
r
r
o
r
f
la
g
d
a
t
a
r
a
t
e
w
a
r
n
in
g
f
la
g
r
e
s
e
t
y
e
s
n
o
y
e
s
n
o
y
e
s
n
o
t
r
ig
g
e
r
f
in
is
h
e
d
t
r
ig
g
e
r
o
c
c
u
r
e
d
c
a
r
d
e
r
r
o
r
y
e
s
n
o
e
x
t
.
p
o
w
e
r
e
v
e
n
t
L
E
D
is
o
ff
L
E
D
is
o
p
e
r
a
t
in
g
b
y
it
s
u
s
u
a
l
w
a
y
(
u
n
a
ff
e
c
te
d
)
.
S
e
e
c
h
a
p
t
e
r
1
.
6
f
o
r
f
u
r
t
h
e
r
in
f
o
r
m
a
t
io
n
.
L
E
D
is
g
r
e
e
n
L
E
D
is
f
la
s
h
in
g
g
r
e
e
n
L
E
D
is
o
r
a
n
g
e
L
E
D
o
r
a
n
g
e
is
f
la
s
h
in
g
L
E
D
is
r
e
d
L
E
D
r
e
d
is
f
la
s
h
in
g
g
g
o
o
r
r
S
t
a
t
u
s
D
a
t
a
o
o
g
r
o
g
g
g
L
E
D
is
g
r
e
e
n
,
f
la
s
h
in
g
o
r
g
a
n
g
e
g
r
O
F
F
W
h
ile
lo
g
g
in
g
t
h
e
d
a
t
a
r
a
t
e
is
w
a
t
c
h
e
d
c
lo
s
e
ly
:
I
f
t
h
e
S
D
c
a
r
d
s
p
a
c
e
is
<
1
0
%
,
t
h
e
s
t
a
t
u
s
L
E
D
is
f
la
s
h
in
g
o
r
a
n
g
e
.
T
h
e
lo
g
g
in
g
s
t
o
p
s
if
n
o
s
p
a
c
e
is
a
v
a
ila
b
le
.
I
f
t
h
e
d
a
t
a
r
a
t
e
is
c
r
it
ic
a
l
b
u
t
n
o
m
e
s
s
a
g
e
s
a
r
e
l
o
s
t
,
t
h
e
d
a
t
a
L
E
D
is
f
la
s
h
in
g
o
r
a
n
g
e
.
T
h
e
L
E
D
s
t
o
p
s
f
la
s
h
in
g
if
d
a
t
a
r
a
t
e
d
e
c
r
e
a
s
e
s
.
T
h
e
lo
g
g
in
g
c
o
n
t
in
u
e
s
u
n
in
t
e
r
r
u
p
t
e
d
.
c
o
n
t
in
u
e
s
u
n
in
t
e
r
r
u
p
t
e
d
.
I
f
t
h
e
d
a
ta
r
a
t
e
is
t
o
o
h
ig
h
a
n
d
m
e
s
s
a
g
e
s
a
r
e
lo
s
t
,
t
h
e
d
a
t
a
L
E
D
is
f
la
s
h
in
g
r
e
d
.
T
h
e
L
E
D
d
o
e
s
n
o
t
s
t
o
p
b
lin
k
in
g
u
n
t
il
t
h
e
p
o
w
e
r
is
s
w
it
c
h
e
d
o
f
f
.
T
h
e
lo
g
g
in
g
g
g
g
s
d
c
a
r
d
s
p
a
c
e
<
1
0
%
?
s
p
a
c
e
w
a
r
n
in
g
f
la
g
y
e
s
f
r
e
e
s
p
a
c
e
?
n
o
o
y
e
s
g
r
v
a
lid
S
D
c
a
r
d
in
v
a
lid
S
D
c
a
r
d
n
o
S
D
c
a
r
d
CANcaseXL and CANcaseXL log Manual
- 14 - Version 4.0 © Vector Informatik GmbH
2.5 Replacing Piggybacks
Warning: When performing this operation be sure not to touch the top or bottom of
the boards (CANcaseXL/log main board or CANpiggies).
1. First, loosen the CANcaseXL/log housing screws on the side with the D-SUB 9
connector. This requires removing the two black decorative caps. Then carefully
pull the PC-board out of the housing.
2. You will find mounting location 1 (Channel 1) at the center of the PC-board and
mounting location 2 (Channel 2) at the edge of the PC-board.
3. Each of the two Piggybacks is fastened by a screw and retainer. Please loosen
the appropriate screw including the retainer and carefully remove the Piggyback
from the mounting location.
4. Insert the replacement Piggyback. When doing this please make sure that the
single and dual-row connectors are not laterally offset.
5. Secure the new Piggyback with the appropriate screw and retainer.
6. Place the CANcaseXL/log main board back in the housing verifying that it is
inserted properly. This operation involves placing the housing on a table with its
back side (side with the bar code) facing upward. Then the main board with is
inserted into the upper guide rails with the Piggybacks facing upward.
7. It should be possible to slide the main board in the housing up to a few
millimeters from the end without forcing it in. Close the housing by applying light
pressure, and then secure it with the appropriate screw fasteners. The screws
should be secure but not excessively tight.
8. Please also attach the two black decorative caps.
Manual CANcaseXL and CANcaseXL log
© Vector Informatik GmbH Version 4.0 - 15 -
2.6 Technical Data
CANcaseXL/log
Housing Robust metal housing
Display
Status display with 3 LEDs per channel
Channels 2x, independent
Transceiver
Pluggable CANpiggies bzw. LINpiggies
CAN controller
2 Phillips SJA 1000
Microcontroller
ATMEL AT91R40008 32bit 64 MHz
Max. baud rate
1 Mbit/s
Time stamp accuracy
1µs
Error frame
Detecting and generating
PC interface
USB 1.1 and 2.0
Ext. Voltage supply (typ.)
7 V … 33 V
Current supply
by USB, external supply optional
Current consumption
(without SD card)
150mA for CANcaseXL/log
Typ. 30mA for CANpiggy 251
Memory media
SD card (max. 2 GB)
Configuration
Plug & Play
Dimensions
approx. 105 mm x 85 mm x 32 mm
Weight
approx. 210 g without CANpiggies
Temperature range
Operating: -20...70 °C
Shipping and storage: -40...85 °C
Relative humidity of ambient air
15 %...95 %, not condensation
Software requirement
Windows 2000 / XP / Vista
CANcaseXL log
Operating modes Interface and Logger
Memory function
Logging on SD card
Additional display Status display with 2 LEDs
Extras
Real time clock and piezom buzzer
Start up time (logger mode)
1 second after switching on
Current supply
External in Logger mode
Manual Appendix A: Address table
3 Appendix A: Address table
Vector Informatik GmbH Vector Informatik GmbH
Ingersheimer Straße 24
D-70499 Stuttgart
Phone : +49 (711) 80670-0
Fax : +49 (711) 80670-110
http://www.vector-informatik.de
Vector CANtech, Inc. Vector CANtech, Inc.
Suite 550
39500 Orchard Hill Place
USA-Novi, Mi 48375
Phone : +1 (248) 449 9290
Fax : +1 (248) 449 9704
http://www.vector-cantech.com
Vector Japan Co., Ltd. Vector Japan Co., Ltd.
Seafort Square Center Bld. 18F
2-3-12, Higashi-shinagawa, Shinagawa-ku
J-140-0002 Tokyo
Phone : +81 3 (5769) 7800
Fax : +81 3 (5769) 6975
http://www.vector-japan.co.jp
Vector France SAS Vector France SAS
168, Boulevard Camélinat
F-92240 Malakoff
Phone : +33 (1) 4231 4000
Fax : +33 (1) 4231 4009
http://www.vector-france.com
VecScan AB VecScan AB
Theres Svenssons Gata 9
SE-41755 Göteborg
Phone : +46 (31) 76476-00
Fax : +46 (31) 76476-19
info@vecscan.com
http://www.vecscan.com
Vector Korea IT Inc. Vector Korea IT Inc.
Daerung Post Tower III, 508
182-4 Guro-dong, Guro-gu
Seoul 152-790
REPUBLIC OF KOREA
Phone : +82(0)2 2028 0600
Fax : +82(0)2 2028 0604
www.vector-korea.com
© Vector Informatik GmbH Version 4.0 - 17 -
Appendix A: Address table Manual
- 18 - Version 4.0 © Vector Informatik GmbH
Vector GB Limited Vector GB Limited
Rhodium
Blythe Valley Park
Solihull, Birmingham
B90 8AS, UK
Phone : +44 (0) 754 9001197
http://www.vector-gb.co.uk
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Vector CANcaseXL log User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI