Focal Point ID+ 4.5" Downlight FLC4D / LC4, ID+ 4.5" Wall Wash FLC4W / LC4 Installation guide

  • I have reviewed the instructions for the Focal Point id+ series round housings. This document specifies installation guidelines and features for FLC4D, FLC4W, FLC6D and FLC6W models. It covers aspects such as installation prior to drywall, securing to structure, bar hanger options, and emergency features. I'm ready to answer your questions.
  • Must the luminaire be installed before the drywall ceiling?
    Do the grid luminaires need to be secured?
    Are bar hangers included?
    Is there an integrated test switch?
    Who should install these luminaires?
IS0584 REV. D 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 3
non-emergency - thermally protected, non-ic
GRID - 1/2" CONDUIT & CLIP (BY OTHERS)
X2
2
id+ 4.5" & 6" round housing
FLC4D | FLC4W | FLC6D | FLC6W
Luminaires must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
4x4
key
power off power on
level attention
see additional instructions
LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING.
ALL GRID LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE.
emergency - integral test switch cp - emergency/non-emergency
flc4d | flc4w
flc4d | flc4w
flc6d | flc6w
flc6d | flc6w
5 1/8
1
7 3/46 5/89 5/8
3
6" overlap 6" ush4.5" overlap 4.5" ush
flc4d | flc4w | flc6d | flc6w
A
TO SET CEILING
THICKNESS SEE FOCAL
POINT INSTRUCTION SHEET
IS0586
optional
bar hangers sold separately
IS0584 REV. D 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 3
Fixtures must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
DRYWALL - BAR HANGERS
make electrical connections
54
METAL STUDS
x4
3
WOOD STUDS
2b x4
GRID - BAR HANGERS (SOLD SEPARATELY)
X2 3 4a2
4b multiple luminaires only
x4
2a x4
Contractor is responsible for adequately reinforcing walls and/or ceilings to support xture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or
ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0584 REV. D 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 3
EMERGENCY - INTEGRAL TEST SWITCH
DO NOT MATE CONNECTOR
UNTIL INSTALLATION
IS COMPLETE AND A.C.
POWER IS SUPPLIED
A B
BATTERY UNIT CONNECTOR INSIDE
DRIVER SERVICE
1
FOR EMERGENCY INTEGRAL
TEST SWITCH INSTALLATION
SEE FOCAL POINT
INSTRUCTION SHEET IS0586
C
FLUSH TRIM MUD-IN
2DO NOT REMOVE DUST
COVER UNTIL TAPE AND
MUD-IN COMPLETE
MUD CASTING WILL BE SLIGHTLY
RECESSED WHEN BAR HANGERS ARE
PROPERLY POSITIONED.
3ADJUST JACK SCREWS TO LEVEL
MUD CASTING TO CEILING
X4
7 3/4
1
9 5/8
4.5" 6"
CP HOUSING
1” MAX. CEILING THICKNESS
SEE BATTERY MANUFACTURER
INSTRUCTIONS
emergency maximum mounting height:
downlight trim: 23.00'
wall wash trim: 19.00'
/