Focal Point ID+ 4.5" x 4.5" Adjustable Accent FLCS44 / LCS44 Installation guide

Type
Installation guide
©2021 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
1 of 5
IS0783 REV. A
ID+ 4.5" x 4.5" Adjustable
Square Overlap — FLCS44 | LCS44
Luminaires must be installed by a qualified
electrician (check with local and national
codes for proper installation).
To prevent electrical shock, disconnect
electrical supply before installation or
servicing.
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
fixture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC. Any
reproduction in part or whole without the
written permission of Focal Point, LLC is
prohibited.
POWER OFF
POWER ON
LEVEL
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
BEFORE YOU BEGIN COMPONENT KEY
INSTRUCTION KEY
T-Housing
IC Rated Housing
Emergency - Remote Test Switch
Chicago Plenum Housing
Beamspread optic,
shipped installed
(replacement kits availalbe)
TRIM
OPTIONAL BAR HANGERS  SOLD SEPARATELY
Solite Lens Spot Optic,
no lens
-15˚ tilt
Spot Optic,
no lens
15˚-30˚ tilt
Spot Optic,
no lens
25˚-40˚ tilt
FOCAL POINT
FLCS4-BH-KIT
2 of 5
IS0783 REV. A ©2021 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
5 1/45 1/4
GRID  /" CONDUIT & CLIP BY OTHERS
GRID  BAR HANGERS SOLD SEPARATELY
DRYWALL  BAR HANGERS SOLD SEPARATELY
METAL STUDSWOOD STUDS
LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING.
ALL GRID LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE.
1 3
4
2b
3
2a
2
3x4
x4
x4
x2
2MULTIPLE LUMINAIRES ONLY
44a
4b
x4
3 of 5
IS0783 REV. A ©2021 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
EMERGENCY  REMOTE TEST SWITCH
ABOVE CEILING ACCESS REQUIRED
5.25"
5.25"
Ø
.75"
7.80" ±.25"
5.18"
10.43" ±.25"
B
F
A
D
C
E
511
6
7
TIGHTEN SCREW TO SECURE
BAR HANGER IN PLACE
RELEASE TEST SWITCH FROM
BRACKET PRIOR TO INSTALLATION
ADJUST TEST SWITCH UNTIL
CANOPY IS FLUSH WITH CEILING BATTERY UNIT CONNECTOR INSIDE
3/16" max
above ceiling
MAKE ELECTRICAL CONNECTION
SEE
BATTERY MANUFACTURER
INSTRUCTIONS
Emergency maximum
mounting height: 19'
4 of 5
IS0783 REV. A ©2021 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
ROTATE MAXIMUM ROTATION: 
TILT MAXIMUM TILT: 
OPTIC SERVICE
TRIM INSTALLATION
8A
9A
A
10a
8B
9B 9C
B
ADJUST ANGLE TO ZERO TILT
OPTIC ENGAGES WITH
TWIST & LOCK MECHANISM
REVERSE STEPS TO
INSTALL BEAMSPREAD OPTIC
ENSURE LED MODULE & TRIM
DO NOT INTERFERE
BEFORE INSTALLING
SP & SP: TRIM IS DIRECTIONAL,
ENSURE PROPER ORIENTATION
PUSH BACK ON HEATSINK
NOTCH TO TILT. PUSHING UP
MAY CAUSE BINDING.
PULL FORWARD ON HEATSINK NOTCH
TO REDUCE/ADJUST TILT.
PULLING DOWN MAY CAUSE BINDING.
5 of 5
IS0783 REV. A ©2021 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
DRIVER SERVICE
1
2 3
TILT & ROTATE LED MODULE
AWAY FROM DRIVER.
SEE INSTALLATION STEPS 8 & 9
FOR INSTRUCTIONS.
SPOT OPTIC TILT KIT SOLD SEPARATELY
A
DC
B
SP30 & SP40 SHIP WITH
SHROUDS INSTALLED.
SPOT OPTICS KITS ARE AVAILABLE
AS REPLACEMENTS OR IF TILT
ANGLE CHANGES FROM
WHAT WAS SPECIFIED.
Distribtuion: Spot (SP)
Optic Description Tilt Range
SL* Solite Lens 0˚– 40˚
SP00* Spot Optic, No Lens 0˚– 15˚
SP30 Spot Optic, No Lens 15˚– 30˚
SP40 Spot Optic, No Lens 25˚– 40˚
*Shroud not required
SP: 15˚– 30˚
SP: 25˚– 40˚
10b
THE  SETS OF
TRIM MOUNTING
LOCATIONS ARE OFFSET
TO ENSURE TIGHT
TRIMTOCEILING FITMENT.
ROTATE TRIM  AND RE
INSTALL FOR BETTER FIT.
OPTIONAL
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Focal Point ID+ 4.5" x 4.5" Adjustable Accent FLCS44 / LCS44 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI