Focal Point Skydome Edge Acoustic AUSDEP Installation guide

Type
Installation guide
1 of 2
IS0734 REV. B
©2021 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
321
BEFORE YOU BEGIN
INSTRUCTION KEY
 PEOPLE RECOMMENDED FOR INSTALLATION
COMPONENT KEY
Flange Plate
Canopy
Finishing Plate
CANOPY ASSEMBLY
Fixtures must be installed by a qualified
professional (check with local and national
codes for proper installation).
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
fixture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC. Any
reproduction in part or whole without the
written permission of Focal Point, LLC is
prohibited.
Skydome® Edge Acoustic
AUSDEP-2 | 3 | 4
Install 1/4" Rods (By Others)
Secure Rods To Structure Above
Threaded Rods Must Extend
.80 Min/.85 Max Beyond Ceiling Plane
.80" min
.85" max
2.52"
AirCore Technology
9
64 11
5
7
2 of 2
IS0734 REV. B ©2021 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
Rotate Internal Sheild
To Properly Orient Cables Tighten Screws After Cables Are Oriented
11
11
8
10
Orient Cable Grippers
To Tilt Towards Center Of Luminaire
Set Suspension Cable
To Desired Length
2FT - 15" Minimum
3FT - 30" Minimum
4FT - 45" Minimum