MK KCMR701 is a programmable thermostat that provides accurate temperature control for various heating systems, including gas and oil boilers, thermal actuators, zone valves, and electric heating. It features a user-friendly interface with a backlit display for easy programming and monitoring. The thermostat offers customizable settings for time, temperature, and system parameters, allowing users to tailor it to their specific needs and preferences. With its energy-saving features, the MK KCMR701 helps optimize heating efficiency and reduce energy consumption.

MK KCMR701 is a programmable thermostat that provides accurate temperature control for various heating systems, including gas and oil boilers, thermal actuators, zone valves, and electric heating. It features a user-friendly interface with a backlit display for easy programming and monitoring. The thermostat offers customizable settings for time, temperature, and system parameters, allowing users to tailor it to their specific needs and preferences. With its energy-saving features, the MK KCMR701 helps optimize heating efficiency and reduce energy consumption.

®
MK Electric
Novar ED&S Ltd
The Arnold Centre, Paycocke Road, Basildon,
Essex SS14 3EA. U.K.
Tel: +44 (0) 1268 563000
Fax: 01268 563405
(UK Sales)
Fax: +44 (0) 1268 563360
(International)
web site: www.mkelectric.co.uk
Technical queries should be made to:
MK Electric, Technical Sales and Services Department
The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA
Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064
All marks in this document identified with a R or TM symbol
adjacent to the mark are Trade Marks of Novar ED&S Limited.



= M3.5
= N
o
6
42010938-006 R1
1.0-2.5mm²
6mm max.

OFFMANAUTO
1 2 3 4 5 6 7
KCMR700
KCMR700 KCMR700
KCMR700KCMR700
 


You have now installed the Programmable Thermostat. For gas boiler applications, the factory system settings
will not need to be changed (for other applications see below). You can now use the  to program
the unit and demonstrate how it works to the homeowner.


Gas Boiler (<30kW)
Oil Boiler
Thermal Actuator
Zone Valve
Electric Heating
(resistive load 3-5A)

Cycle /Hour
6
3
12
6
12
Minimum ON
time
1
4
1
1
1

Note: All parameters listed below belong to
category 2 – system parameters (see Installer
Parameter Table)
No changes required
Set 1:Ot parameter to 4
Set 2:Cr parameter to 3
Set 2:Cr parameter to 12
No changes required
Set 2:Cr parameter to 12

 Press the button.

Press and hold the button and the two
 or buttons together.

The unit will display the first parameter of installer
parameter group category 1 (
from Parameter No. 1
to 19
).

Press the or button to change the factory
setting. The display will flash indicating that a
change has been made.

Press the green button to confirm the change.
The display will stop flashing.

Press the button to go to the next parameter.

Press the  button to go to Installer
parameter group category 2 (from Parameter No. 1
to 5).
 To exit installer mode, press the ,  or
button.
AM-PM / 24hr
Display
Reset Time/ Temp
Program
Upper Temp Limit
Lower Temp Limit
Temperature Offset
Proportional Band
Width
Reset Parameters to
Factory Defaults
Minimum boiler ON
time
Cycle Rate
Pump Exercise
1:CL
2:rP
6:UL
7:LL
12:tO
13:Pb
19:FS
1:Ot
2:Cr
5:PE
Always remember to press the green button to confirm that you want to store the new Installer Set-Up
setting. To exit the Installer Set-Up Mode press the or button.

To enter the diagnostic mode press the button then press and hold the button for 5 sec. The unit will enter
the user settings mode. Next press and hold the and buttons together. The unit will hold the relay on
for 5 minutes and the following information will be available on the display: model ID, date code (WW/YY) and
checksum. To view this info press the or button.
Display
24
1
35
5
0
1.5
1
1
6
0

 

Description
24 hr clock display
format
Time / Temp profile set to
factory default
Changes to 0 when one
of the time/temp profiles
are changed
35°C Upper Temp. Limit
5°C Lower Temp. Limit
No temperature offset
Proportional band of 1.5
degree
All settings at factory
defaults.
Changes to 0 when one of
the parameter is changed
1 minute minimum ON
time
6 cycles per hour (cph)
Pump exercise disabled
Display
12
0
1
21-34
6-20
-3..3
1.6..3
0
1
2..5
3,9,12
1

Description
12 hr – AM/PM clock
display format
Time / Temperature are as
programmed
To restore the factory
profile set to 1
21°C to 34°C adjustment
in 1°C steps
6°C to 21°C adjustment in
1°C steps
-3°C to +3°C adjustment
in 0.1°C steps
1.6°C to 3.0°C adjustment
in 0.1°C steps
Settings are as modified
above
To restore the factory
profile set to 1
Selection of 2, 3, 4 or 5
minutes minimum ON time
Selection of 3, 9 or 12 cph
Pump exercise enabled
COPY
DAY
DAY
1..4
1 2 3 4 5 6 7
AUTO
MAN
OFF
1 2
COPY
DAY
DAY
1..4
MANAUTO
1 2 3 4 5 6 7
AUTO
MAN
OFF

  • Page 1 1
  • Page 2 2

MK KCMR701 Installation guide

Type
Installation guide
This manual is also suitable for

MK KCMR701 is a programmable thermostat that provides accurate temperature control for various heating systems, including gas and oil boilers, thermal actuators, zone valves, and electric heating. It features a user-friendly interface with a backlit display for easy programming and monitoring. The thermostat offers customizable settings for time, temperature, and system parameters, allowing users to tailor it to their specific needs and preferences. With its energy-saving features, the MK KCMR701 helps optimize heating efficiency and reduce energy consumption.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI