Function 5: Time Switch
Wall Transmitter Function
Press button I
Switch on with running time
(parameter)
Press button O Switch off
Parameters
1 2 min running time
2 1 min running time
3 5 min running time
4 10 min running time
5 20 min running time
6 30 min running time
7 60 min running time
8 120 min running time
Function 6: Fan Control
Wall Transmitter Function
Press button I Switch on delay (3 minutes)
Press button O Activate running time parameter
Parameters
1 6 min delay time
2 2 min delay time
3 10 min delay time
4 15 min delay time
5 20 min delay time
6 30 min delay time
Function 7 - Light Scenes
Wall Transmitter Function
Press button O briefly Switch on light scene A/C
Press button O long Store light scene A/C
Press button I briefly Switch on light scene B/D
Press button I long Store light scene B/D
Parameters
1 button O = light scene A, button I = light scene B
2 button O = light scene C, button I = light scene D
OPERATION WITH ECHO WINDOW CONTACT
Echo/Echo
Window Contact
Notes:
– The assignment and programming of a window contact is also
possible before the installation.
– Control of the receiver with window contacts and window handles
(beginning with Version 1.1).
Function 8 and 9: Switch On / Off
Window Contact Function 8 Function 9
Window contact opened Switch on Switch off
All window contacts closed Switch off Switch on
Parameters
1 Window contact function
2 Window handle function
TROUBLESHOOTING:
New system or existing system
• Check power supply (electrician only).
• Check connected electrical loads.
• Check the system’s surroundings for changes that could cause interference
(e.g. metal cabinets, furniture or walls which have been moved).
• If the transmitter/receiver operates at a reduced distance, the radio signal was
encountering interference or it was operating outside the transmission range.
• Use the receiver at a better location.
• Delete all transmitters and reprogram the receiver.
Receiver switches by itself
• This may be caused by operation of an external transmitter that was
coincidentally assigned to the receiver.
• Delete all transmitters and reprogram the receiver.
Radio signal range limitations
• Use of the receiver in the vicinity of metal objects or materials with metal
components. Maintain a distance of at least 10cm
• Moist materials.
• Devices which emit high-frequency signals (e.g. audio and video systems,
computers, electronic ballasts in light fixtures). Maintain a distance of at least
0.5m
OTHER INFORMATION:
Disposal:
At the end of their useful life the packaging and product should
be disposed of via a suitable recycling centre. Do not dispose
of with your normal household waste. Do not burn.
EU R&TTE Declaration:
Novar ED&S Ltd hereby declares that the K5437 Switch Receiver is in
compliance with the essential requirements and other relevant
provisions of the European Radio and Telecommunications
Terminal Equipment (R&TTE) directive, 1999/5/EC.
A copy of the Declaration of Conformity for this product may be found at:
www.electrical.honeywell.com
Guarantee:
MK Electric undertakes to replace or repair at its discretion goods should
they become defective within 10 years solely as a result of faulty
materials and workmanship. Understandably if the product has not been
installed, operated or maintained in accordance with the instructions,
has not been used appropriately or if any attempt has been made to
rectify, dismantle or alter the product in any way the guarantee will be
invalidated.
The guarantee states MK Electric’s entire liability. It does not extend to
cover consequential loss or damage or installation costs arising from the
defective product. This guarantee does not restrict, infringe or in any
way affect the normal statutory or other rights of the consumer.
For help and advice please contact the technical service helpline: 01268 563720
Email: mk.technical@honeywell.com
MK Electric Telephone: +44 (0)1268 563000
The Arnold Centre, Paycocke Rd, , Fax: +44 (0)1268 563404
Basildon Essex SS14 3EA UK Email: mk.orderenquiries@honeywell.com
MK Electric (Middle East) Telephone: (+971) 4 807 3200
Honeywell ME, FZE, P.O. Box 18530, Fax: (+971) 4 881 5733
Jebel All, Dubai U.A.E.
www.electrical.honeywell.com
Novar ED&S Ltd, (A Honeywell Company)
Arlington Business Park, Bracknell,
Berkshire, RG12 1EB, UK
Copyright Novar ED&S Ltd 2011. All rights reserved.
50064828-001_A