MK VP122 Installation guide

Type
Installation guide
Description/List no.
Socket Spacer
VP129
Dado
Internal Corner
VP181
Skirting Internal
Corner
VP191
Dado
External Corner
VP182
Skirting External
Corner
VP192
Dado
End Cap
VP183
Skirting End Cap
VP193
Dado Joint Cover
VP184
Skirting Joint Cover
VP194
Dado Flat Angle
VP185
Skirting Flat Angle
Up VP195
Skirting Flat Angle
Down VP196
PRESTIGE 3D
Data Trunking System
Contents
Guarantee
Planning the Installation
Product Classification
Product Identification
Installation
Please leave this leaflet with the end user for future reference
48396PL Ed2
The Company undertakes to replace or repair at its discretion,
products should they become defective within 10 years in the case
of Cable Management products, solely as a result of faulty materials
or workmanship. Understandably, if the product has not been
installed or maintained in accordance with the Company’s instruction,
has not been used appropriately, or if any attempt has been made to
rectify, dismantle or alter the product in any way, the guarantee will
be invalidated.
This Guarantee states the Company’s entire liability. It does not
extend to cover consequential loss or damage or installation costs
arising from the defective product. This Guarantee does not restrict
or infringe the normal statutory or other rights of the consumer.
MK Electric
Novar ED & S Ltd., The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, UK
Telephone: +44 (0) 1268 563000
Facsimile: 01268 563405 (UK Sales) +44 (0) 1268 563360 (International Sales)
E-mail: technical@novar.com Website: www.mkelectric.co.uk
All marks in this document identifi ed with a ® or ™ symbol adjacent to the
mark are Trade Marks of Novar ED & S Ltd.
GUARANTEE
Establish Layout, Paying Particular Attention To:-
- Direction Changes
- Feed Positions
- Component Spacing
To ensure a safe installation, this product must be installed by a
competent person, in accordance with the current edition of the
IEE Wiring Regulations (BS 7671) and Building Regulations.
1, 2 and 3 Gang Frames conform to the requirements of BS 4662
where applicable. If you are in any doubt regarding the installation
or application of this product please contact: Technical queries should
be made to:
MK Electric Technical Sales and Services Department
The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, UK
Telephone +44 (0) 1268 563720 Fax: +44 (0) 1268 563064
CLEANING
The exterior should only be cleaned using a damp cloth.
DISPOSAL INSTRUCTIONS
The product and packaging should be disposed of via standard
civic amenity facilities.
PRODUCT IDENTIFICATION
Description/List no.
Dado
Flat Tee
VP187
Skirting Flat Tee
VP197
Adaptor
Mini-Trunking/
Conduit
VP188
Screening Divider
1.5m length
VP30
Screening Cable
200mm
VX31
Screening Cable
500mm
VX32
Cable Retainer
VP105
Security Fixing Kit
VTS1000
External Corner - Data Sweep
2
50 mm
Fix screws
top & bottom
Flat Tee
4
Fix screws
top & bottom
235 mm
202 mm
117 mm
Fix screws
top & bottom
OR
PLANNING THE INSTALLATION
PRODUCT CLASSIFICATION
Fix screws
top & bottom
1
Fixing Main Carrier
INSTALLATION
Internal Corner
3
4A
Flat Tee Cable Options
++
4B
KEY: Power
Data
Description/List no.
Main Carrier
VP180
Straight Cover
VP100
Curved Cover
VP110
Square Cover
VP115
1 Gang Back Box
45mm depth
VP121
2 Gang Back Box
45mm depth
VP122
3 Gang Back Box
45mm depth
VP123
50 mm
MAX
(typical)
50 mm
MAX
(typical)
500 mm
MAX
57mm
170mm
164mm
3mm
End cap fi xing
screw
10 mm
MIN
(skirting)
Adaptor Assembly
11
Cabling Back Boxes
Assembly of Covers
continued Complete Assembly (fi xing screws optional)
12 13
5
Flat Angle
218 mm
133 mm
Fix screws
top & bottom
Allow 3 mm for cover
133 mm
to centre
of main
carrier
Cabling
External Corner
Data Sweep
Hinged Lid Cable Tray
Cable Retainers
Screening Assembly (optional)
The covers can be
further secured,
by using the screw
xing kit
988 10
Assembly of Covers
Covers to be
cut back when
interfacing
with fi ttings
KEY: Power
Data
Screening Assembly (optional)
6B
Mounting Back Boxes
For conduit
20 mm and 25 mm
drill appropriate size
Cut out
markings
7
6A
Maintain
power cable
segregation
behind box
Cut screening
divider to length
and lay in upper
or bottom
compartment
as shown
Only remove
knockouts where
appropriate
Fit screening cable to
tag of screening divider
Remove appropriate
knockout as required
OR
Screening divider shown on
top compartment only for clarity
For cable capacity refer to Catalogue
or MK Technical Sales Service dept.
Steel
PVC
Must be
suitably
earthed
Knockout for Data
For YT2 and YT4
cut appropriate size
OR
90º +/-5º
90º +/-5º
96mm
170mm
min. column size
50mm
12mm
76mm
To release back box from
trunking - lift tab
Crossover
(185 mm for VP196)
(268 mm for VP196)
(185 mm for VP196)
  • Page 1 1