ACT ACT1020 - WIRING FOR ENTRYEXIT User manual

Type
User manual
Card/Prox Reader
The +5V reader supply on ACT controllers is normally rated
at 100mA. Typically this is sufficient to power 2 ACT readers.
Note however that readers from other manufacturers may need
to be powered separately if their current requirements exceed
this or if they require 12V.
The standard wiring colours for
ACT1020 reader is shown above.
Readers should be a maximum of 30m
from the controller when powered
from +5V and a maximum of 100m
when powered from +12V.
U nit 8 Tallaght B usiness Centre, W hitestown, T allaght, Dublin 24, Ireland.
Telephone: 353 1 462 2585. T elefax: 353 1 462 2587. E -mail: s ales @ accesscontrol.ie W eb: www.accesscontrol.ie
Wiring for Entry/Exit
ACT1020
ACT1020
Reader (Exit)
Wire both readers in parallel but leave
the SENSE line on the Exit reader unconnected.
Controller
SENSE
CLOCK
DATA
+5V
0V
RED
GREEN
ACT1020
Reader (Entry)
For Wiegand readers .
Wire both readers in parallel but connect D0
line of the exit reader into the SENSE line on
the controller,leave the SENSE line on the
Exit reader unconnected.
White
Green
Blue
Red
Black
Brown
Yellow
Orange
SENSE
CLOCK/ Data1
DATA / Data 0
+5V
0V
RED
GREEN
(Buzzer Ctrl)
Wiring for Clock and Data / Wiegand Reader
Reader Specification
Voltage: 5-12V DC
Current: 15 mA standby, 25 mA maximum
Operating Temperature: -10 degres C to +55 degrees C
Media: HID Proximity cards and key fobs
Read Range: 10 cm with prox card 11
  • Page 1 1