ACT ACTPRO PRODUCT RANGE Operating And Installation Instruction

Type
Operating And Installation Instruction

ACT ACTPRO PRODUCT RANGE

The ACT ACTpro product range is a versatile and powerful access control system that offers a wide range of features and benefits. With its ability to support multiple entry and exit readers, the ACT ACTpro can be used to control access to a variety of different areas, such as offices, schools, and hospitals. The system also supports a variety of different reader technologies, including RFID 125KHz, MIFARE Classic, and DESFire EV1, making it compatible with a wide range of access control cards and fobs.

In addition to its access control capabilities, the ACT ACTpro also offers a number of other features, such as break glass monitoring, voltage monitoring, and reader current limiting. These features help to ensure the security and reliability of the system.

ACT ACTPRO PRODUCT RANGE

The ACT ACTpro product range is a versatile and powerful access control system that offers a wide range of features and benefits. With its ability to support multiple entry and exit readers, the ACT ACTpro can be used to control access to a variety of different areas, such as offices, schools, and hospitals. The system also supports a variety of different reader technologies, including RFID 125KHz, MIFARE Classic, and DESFire EV1, making it compatible with a wide range of access control cards and fobs.

In addition to its access control capabilities, the ACT ACTpro also offers a number of other features, such as break glass monitoring, voltage monitoring, and reader current limiting. These features help to ensure the security and reliability of the system.

ACTpro 120e Single Door Station
with 12V DC 2A power supply
Operating and
Installation Instructions
ACT Product Code: ACTpro 120e
pro
ACTpro 120e PSU Operating and Installation Manual
ACTpro 120e PSU Installation Guide
The ACTpro 120e is a single door station with an integrated 12V DC 2A power supply. It
expands any of the existing ACTpro controllers (ACTpro 4000, 4200, 1520e, 1500e) by
one door.
The 2A output current is used to power
the door station and supply the battery
recharge current. 500mA is reserved for
battery recharge and to power the door
station. Therefore 1.5A is available to power
readers and the lock.
See “Installation Instructions” on page 6.
Example: Power budget of a typical single door read in/out installation.
Total Current Available 2000mA
ACT Door Station and Battery Recharge 500mA
ACT Reader X 2 200mA
Typical Mag Lock 800mA
Total Consumption 1500mA
Spare Capacity 500mA
Electrical Speci cation
Input Voltage 230VAC +/- 10%
Frequency 47-53Hz
Input Fuse 625mA 250V anti-surge fuse
Output Voltage 13.65V (+/-5%)
Max Load 2A @ 25°C
Electronic Output Fuse Yes
Battery Current ~0.5A for a battery discharged to ~10V.
Battery Protections Deep Discharge/Over Charge/Reverse Polarity
Operating Temperature -10°C to +50°C
1
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
2
BREAK GLASS UNIT
(Double Pole)
POLE A POLE B
DOOR
NETWORKS
DOOR
CONTACT
NC
C
NO
NC
C
NO
OP3
OP2
0V
AUX I
DC
PB
A
B
0V
0V
+12V
MAINS
PRESENT
B/GL
TAMP
DOORS NETWORK
120e
WIRING DIAGRAM
W
G
B
R
BK
BN
Y
ACT READER WIRE
COLOUR CODING
NC
NO
C
NC
NO
C
12V 0V
0V PSU
IMPORTANT:
Place varistor across all lock terminals
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
AUX RELAY MAIN RELAY
Diagram shows normally energised Magnetic Lock
PUSH TO EXIT
RS485
Break Glass Monitoring
Normally Closed
RED
GREEN
DATA
+12V
OV
SENSE
CLOCK
Normally
Open
Normally
Closed
1 2 3 4 5 6 7 8
ON DIP
Please Note:
If the Mains Present, Door Contact or
Break Glass Inputs are not used, they
should be linked to 0V or disabled via
software.
The Blue Comms OK LED is on while
ACTpro 120e is communicating with
the controller.
Red Fault LED illuminates on:
1. Tamper
2. Break Glass
3. Comms Ofine
4. Mains Fault
5. Voltage Low
6. Current Limiting Fuse (500mA)
FACTORY DEFAULT
This unit should be reset to its
factory default condition before
installation.
To do this, power the unit up with
ALL 8 DIP switches in OFF position.
The unit will beep after 3 seconds.
The unit is now defaulted.
EXIT READERS
For Clock & Data readers, wire
exit readers in parallel but leave
the sense line unconnected.
For Wiegand readers, wire the
DATA 0 of the exit reader to SENSE
on the ACTpro 100e.
Max length 100m with 12V DC
Cable: 8 Core Screened
Belden 9504 or equivalent
From Previous
Door Station/Controller
To Next
Door Station
ACTpro 120e PSU Operating and Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
3
ACTpro 120e PSU Operating and Installation Manual
DIP Switch Addressing:
Door 1 is reserved for the ACTpro 1520e/1500e controller
Door 1 & 2 are reserved for all other ACTpro controllers
(ACTpro 4200, 4000, 3200, 3000, 2000)
01
OFF OFF OFF OFF OFF OFF OFF
ON
02
OFF OFF OFF OFF OFF OFF
ON
OFF
03
OFF OFF OFF OFF OFF OFF
ON ON
04
OFF OFF OFF OFF OFF
ON
OFF OFF
05
OFF OFF OFF OFF OFF
ON
OFF
ON
06
OFF OFF OFF OFF OFF
ON ON
OFF
07
OFF OFF OFF OFF OFF
ON ON ON
08
OFF OFF OFF OFF
ON
OFF OFF OFF
09
OFF OFF OFF OFF
ON
OFF OFF
ON
10
OFF OFF OFF OFF
ON
OFF
ON
OFF
11
OFF OFF OFF OFF
ON
OFF
ON ON
12
OFF OFF OFF OFF
ON ON
OFF OFF
13
OFF OFF OFF OFF
ON ON
OFF
ON
14
OFF OFF OFF OFF
ON ON ON
OFF
15
OFF OFF OFF OFF
ON ON ON ON
16
OFF OFF OFF
ON
OFF OFF OFF OFF
17
OFF OFF OFF
ON
OFF OFF OFF
ON
18
OFF OFF OFF
ON
OFF OFF
ON
OFF
19
OFF OFF OFF
ON
OFF OFF
ON ON
20
OFF OFF OFF
ON
OFF
ON
OFF OFF
21
OFF OFF OFF
ON
OFF
ON
OFF
ON
22
OFF OFF OFF
ON
OFF
ON ON
OFF
23
OFF OFF OFF
ON
OFF
ON ON ON
24
OFF OFF OFF
ON ON
OFF OFF OFF
25
OFF OFF OFF
ON ON
OFF OFF
ON
26
OFF OFF OFF
ON ON
OFF
ON
OFF
27
OFF OFF OFF
ON ON
OFF
ON ON
28
OFF OFF OFF
ON ON ON
OFF OFF
29
OFF OFF OFF
ON ON ON
OFF
ON
30
OFF OFF OFF
ON ON ON ON
OFF
31
OFF OFF OFF
ON ON ON ON ON
32
OFF OFF
ON
OFF OFF OFF OFF OFF
01
02 03 04 05 06 07 08
Required
Address
ON
OFF
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
4
Wiring of entry & exit readers.
For Wiegand Entry Readers wire D0 to DATA Pin on ACTpro Door Station and D1 to
CLOCK pin on ACTpro Door Station.
For Wiegand Exit readers wire the D0 of the exit reader to SENSE pin on ACTpro Door
Stationand D1 to CLOCK pin on ACTpro Door Station.
SENSE
CLOCK
DATA
+12V
OV
RED
GREEN
Entry Reader
Exit Reader
(Do not connect to SENSE)
ACTpro 1050e
Pin & Proximity Reader
ACTpro 1030e
Proximity Reader
Reader Recommended Controller Signal information
Terminal wiring colour input Pin
Block
SENSE White SENSE For Entry readers connect the reader SENSE cable or
terminal to the SENSE input pin.
For Exit readers, do not use this input.
CLOCK Green CLOCK This is the clock or strobe signal input on the ACTpro
120e. Connect the reader CLOCK cable or terminal
on the reader to CLOCK input pin.
DATA Blue DATA This is the Data input.
Connect the reader DATA cable or terminal on the reader
to DATA input pin.
+12V Red +12V Positive +12V DC Supply voltage for the reader.
0V Black 0V 0V Supply Voltage for the reader.
RED Brown RED Red LED control output from the ACTpro 120e.
Connect the reader brown cable to the terminal marked
RED on the door station.
GREEN Yellow GREEN Green LED control output from the ACTpro 120e.
Connect the reader green cable or terminal marked
GREEN on the ACTpro Door Station.
ACTpro 120e PSU Operating and Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
5
ACTpro 120e PSU Operating and Installation Manual
ACTpro 120e Door Station Status Indicators
Blue: Power
This indicates that the
ACTpro 120e has power.
Blue: Communications
Constant illumination indicates
that the door station is online.
Red: Fault
This illuminates to indicate a fault on the system.
Possible causes are:
1. Tamper open: Door station housing is not closed.
2. Break Glass: The fault LED will illuminate if the connected Emergency break
glass switch is activated.
3. Comms Ofine: Door station is ofine.
4. Mains Fault: ACTpro 100e Door Station will accept a mains present signal from a
PSU (pre-wired on ACTpro 120e). This is wired into MAINS PRESENT input on
the PCB. When the PSU has no mains supply the fault is active.
5. Low Supply Voltage: When voltage to the +12V terminal is less than +9V.
6. Fuse Blown: The +12V output on the READER terminals is current limited to provide
short circuit protection. The Fault LED will illuminate if too much current is drawn
from this connection.
!
!
!
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
6
ACTpro 120e PSU Operating and Installation Manual
LED indicators
Green - AC OK Indicates that the AC Mains is within speci cation.
Amber – ON BATTERY Indicates that the battery is supplying the output voltage.
Red - FUSE FAULT Indicates electronic output shutdown fuse is active and
that no power is being supplied to the load.
The maximum current that the PSU can
guarantee is 1.5A plus 0.5A for battery
charging. Beyond this the fuse will trip
and the LED will stay on until the load is
fully disconnected.
Once the load has been disconnected,
remove devices to reduce the current
demand below 1.5A.
It is important to calculate the power
budget adequately. Please refer to the
section on the following page titled
‘Power Budget’ for more information.
Installation Instructions
The ACTpro 120e Door Station is for indoor installation only and must be installed as
permanently connected equipment.
An external mains disconnect device must be  tted. Before installation ensure that the
mains supply to the ACTpro 120e Door Station is disconnected.
Mains power should be connected to ACTpro 120e Door Station by a licensed electrician
in accordance with local/national codes.
Mounting
Mount the ACTpro 120e Door Station directly on to the wall with the supplied screws.
The keyed mounting hole should be screwed  rst to the wall to aid the mounting.
The unit should be installed in a ventilated area that allows for accessibility after
installation.
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
7
L
Mains Power up
Attach a correctly rated mains cable and fasten using
the cable tie.
Use an approved external mains disconnect device.
Apply mains power. Check the ‘AC OK’ LED is on
and measure the +12V output.
Battery insertion
Disconnect the mains.
Ensure the battery has enough charge to supply the load.
Connect the red battery lead to the “+” battery terminal and the black lead to the “–”
terminal.
Apply the mains power and check the “AC OK” Green LED is illuminated.
Remove the mains power and check that “ON BATTERY” Amber LED is illuminated.
If the Amber led is illuminated the battery is now supplying the output.
Re-apply the mains power. The “AC OK” Led will illuminate and the “ON BATTERY” LED
will extinguish.
Power Budget
The PSU can supply up to 2A; 0.5A reserved for battery recharging and to power the door
station. 1.5A remains to power the locks and readers.
A complete access control system will require readers and a lock mechanism all of which
will require power.
The following table should be used for calculating the power budget.
ACTpro reader (1030/1040/1050/1060) 100mA
ACTPro MIFARE reader (1030/1040/1050) 100mA
Typical Mag Lock (consult your supplier) 800mA
N
ACTpro 120e PSU Operating and Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
ACTpro 120e PSU Operating and Installation Manual
ACTpro 120e Features and Specication:
Features:
Main relay and AUX relay
Supports all ACTpro readers (RFID 125KHz, MIFARE Classic, DESFire EV1)
Break glass monitoring
Voltage monitoring
Supports Clock and Data or Wiegand readers
Multiple entry & exit readers
Reader current limiting / short circuit protection
Request to exit
Door monitoring
Tamper and mains present monitoring
Status LED’s
Interlocking
Technical Details:
Relay contact rating Main relay 5A / 50 Vac, AUX relay 1A / 50 Vac
Indoor use only M
Compatible with all ACTpro Controllers ACTpro 4200, 4000, 3200, 3000, 2000,1500e, 1520e
PSU Output Voltage:
12V DC The power supply provides two 12V outputs. One pre-wired to power
the ACTpro Door station. Second is available to power locks.
The full load current shared between the two outputs, ACT recommend
that a maximum of 1.5A is used to power locks and readers. The
remaining 0.5A is used by the door station and battery charging.
Total current from both outputs must not exceed 2A.
Monitoring:
Mains present The PSU MAINS PRESENT output is pre-wired to the MAINS PRESENT
input of the ACTpro 120e door station.
Output Voltage The PSU output voltage level is reported to the ACT Enterprise software
and on the web browser.
Tamper The enclosure lid is tamper monitored.
Note: All faults including Mains Present and Tamper are reported on ACT
Enterprise and via the web browser on the ACTpro 1520e controller.
8
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
9
ACTpro 120e PSU Operating and Installation Manual
Push Button (PB)
Push button is connected between PB input and 0V. When
push button is pressed the main relay is activated for the
confi gured time.
Push button is also referred to as Exit Button, Egress Button,
Request To Exit.
Door Contact (DC)
Connect door contact between DC input and 0V.
Break Glass Monitoring only
The break glass monitoring features only
monitors the break glass status and does
not remove power from the lock. ACT
assumes a double pole break glass unit is
used, one pole to disrupt the power to the
lock the second pole for monitoring.
When the Break Glass is not activated the
B/GL input pin is held low at 0V. When the
Break Glass device is activated the B/GL
input pin will lose the 0V (goes high) and
report a Break Glass event. The lock should
be wired such that when the break glass is
activated power to the lock is removed.
OP3
OP2
0V
AUX I
DC
PB
PUSH TO EXIT
NC C NO
NC
C
NO
NC
C
NO
0V
+12V
MAINS PRESENT
BREAK GLASS
TAMP
EMERGENCY
DOOR RELEASE
MAGNETIC LOCK
Relay
NO C NC
BREAK GLASS
MONITORING
0V
12V
DOOR CONTACT
OP3
OP2
0V
DC
PB
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
Ordering Information:
10
ACT Product Code Product description
Controller
ACTpro 1520e controller with integrated 12V DC 2A power supply
ACTpro 1500e Single door IP controller expandable to 32 doors with ACTpro door stations
ACTpro 100e Single door station
ACTpro 120e ACTpro 100e door stations with integrated 12V DC 2A power supply
Readers
ACT RFID
ACTpro 1030e ACT RFID slimline, proximity reader, IP67
ACTpro 1040e ACT RFID Surface / Flush, proximity reader, IP67
ACTpro 1050e ACT RFID Surface/ Flush, PIN & proximity reader, IP67
ACTpro 1060e ACT PIN only reader, IP67
ACTpro 1030PM Panel mount multi-format proximity reader, IP67
ACTpro 1030e VR Vandal Resistant cover for the ACTpro 1030e
ACTpro MIFARE
ACTpro MIFARE 1030 ACT RFID slimline, proximity reader, IP67
ACTpro MIFARE 1040 ACT RFID Surface / Flush, proximity reader, IP67
ACTpro MIFARE 1050 ACT RFID Surface/ Flush, PIN & proximity reader, IP67
ACTpro MIFARE 1030PM Panel mount multi-format proximity reader, IP67
ACTpro 1030 VR Vandal Resistant cover for the ACTpro MIFARE 1030
ACTpro DESFire EV1
ACTpro DESFire EV1 1030 ACT RFID slimline, proximity reader, IP67
ACTpro DESFire EV1 1040 ACT RFID Surface / Flush, proximity reader, IP67
ACTpro DESFire EV1 1050 ACT RFID Surface/ Flush, PIN & proximity reader, IP67
ACTpro DESFire EV1 1030PM Panel mount multi-format proximity reader, IP67
Cards and Fobs
ACT RFID ISO-B ACT RFID Batch Cards
ACT RFID FOB-B ACT RFID Batch Fobs
ACTpro MIFARE Card ACT MIFARE 1K Cards
ACTpro MIFARE Fob ACT MIFARE 1K Fobs
ACTpro DESFire EV1 Card ACT DESFire EV1 Cards
Software
ACT Enterprise PC application software
Accessories
ACT USB Reader Multi format desktop card reader for ACT Enterprise software
ACTpro 120e PSU Operating and Installation Manual
Ireland Ofce
Unit C1, South City Business Centre,
Tallaght, Dublin 24, Ireland
United Kingdom Ofce
Unit 601, Birchwood 1, Dewhurst Road,
Birchwood, Warrington, WA3 7GB, UK
Ireland: +353 (0)1 466 2570
UK: +44 (0)161 236 9488
www.act.eu
Copyright © 2016 Access Control Technology Ltd. Part No. 18-00100 Issue 1.0
This manual refers to the ACTpro 120e
door station with an integrated 12V
DC 2A power supply. Access Control
Technology Ltd. reserve the right to
change the contents of this manual and
the system it applies to without prior
notice.
While every effort has been taken
by ACT to ensure the accuracy of
the information contained within
this document, ACT assumes no
responsibility for any errors or
omissions. No liability is assumed
for damages resulting from the use
of information contained within this
document.
Certications:
The ACTpro 120e Door Station complies
with the following European directives:
Information technology equipment -
Safety - EN60950-1
EMC Directive - 2004/108/EC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

ACT ACTPRO PRODUCT RANGE Operating And Installation Instruction

Type
Operating And Installation Instruction

ACT ACTPRO PRODUCT RANGE

The ACT ACTpro product range is a versatile and powerful access control system that offers a wide range of features and benefits. With its ability to support multiple entry and exit readers, the ACT ACTpro can be used to control access to a variety of different areas, such as offices, schools, and hospitals. The system also supports a variety of different reader technologies, including RFID 125KHz, MIFARE Classic, and DESFire EV1, making it compatible with a wide range of access control cards and fobs.

In addition to its access control capabilities, the ACT ACTpro also offers a number of other features, such as break glass monitoring, voltage monitoring, and reader current limiting. These features help to ensure the security and reliability of the system.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI