Sunricher SR-2300TS-CCT-US-DT6 User manual

  • Hello! I've reviewed the user manual for the Touch Controller 09.230TCU6.04065. This manual details the features of a DALI dual color touch controller, including its touch-sensitive interface, control over four light zones, and the ability to save lighting scenes. I'm ready to answer your questions about this product and its operation.
  • What is the power supply requirement?
    How many light zones can be controlled?
    Can I save and recall light settings?
DALI Dual Color Touch Controller
Function introduction
Important: Read All Instructions Prior to Installation
Product Data
DO NOT install with power applied to device.
DO NOT expose the device to moisture.
Safety & Warnings
Back side
012
3
4
5
6
7
89
012
3
4
5
6
7
89
(x10)
(x1)
V- D1V+ D2
DC INPU T DALI OU TPU T
43.58 mm
65.58 mm
Back side
DC Power input DALI signal output
DALI Wall Panel
Controller
83.00 mm
19.4 mm
CCT color slider CCT brightness slider
ON/OFF button
4 light zones, click to select,
press and hold down to turn
ON/OFF
Click to switch between
CCT color slider and
brightness slider
Scene button, press and
hold down to save a
scene, click to recall
1*(0~9) for setting
units position
10*(0~9) for setting
tens position
Rotary switches for setting start
DALI address number (0-63),
the number equals to tens
position plus units position
Wiring diagram
123
4
GND
123
4
GND
V+ V+
WW WW
CW CW
WW WW
CW CW
Conne ct with Dual C olor LED Str ip
V+ V+
WW WW
CW CW
WW WW
CW CW
Conne ct with Dual C olor LED Str ip
DALI Master/
DALI Master software
via computer
AC Power
50/60Hz
L
N
G
V+
V-
OUTP UT
INPUT
12V/24V/36V
CV PSU
12-24VDC
PSU
AC 100-240V
012
3
4
5
6
7
89
012
3
4
5
6
7
89
(x10)
(x1)
V- D 1V+ D2
DC IN PUT DAL I OUTPU T
DALI Wal l Panel
Controlle r
Output Signal DALI signal
Power Supply 12-24VDC
Power consumption 200 mA
Operating temperature 0-40°C
Relative humidity 8% to 80%
Dimensions 75x120x29.1mm
09.230TCU6.04065
Touch sensitive.
• Glass interface(white & black).
• Comply to DALI standard protocol IEC 62386-102, IEC
62386-207 and in compliance with DALI products from
other international incorporation.
• 4 light zones are available for switch, dimming and CCT
control, each zone can control 2 DALI addresses.
• Enable to set start DALI address number (0-63) for the 4
zones by rotary switches on the back.
• Enable to save 2 scenes
Operation
Set start DALI address number for the zones by rotary switches on the back:
Set the number as X (0-63):
Zone number Z1 will control DALI addresses X and X+1,
Zone number Z2 will control DALI addresses X+2 and X+3,
Zone number Z3 will control DALI addresses X+4 and X+5,
Zone number Z4 will control DALI addresses X+6 and X+7,
Note: if X is set as 63, zone 1 will control DALI address 63 and 00, zone 2 will control address 01 and 02, zone 3
will control address 03 and 04, zone 4 will control address 05 and 06.