Q-TRAN QUAVO Linear Fixture

Q-tran Q-TRAN QUAVO Linear Fixture, QUAVO Linear Fixture User manual

  • Hello, I am your chat assistant. I have reviewed the installation instructions for the Q-Tran QUOVA STANDARD linear fixture. This document covers everything from cove and surface mounting methods to detailed hardware information and environmental requirements for installation. I am ready to answer your questions about the device or its installation process.
  • What type of power supply should be used with the QUOVA STANDARD fixture?
    What is the ideal temperature and humidity for installation?
    How often should mounting screws be installed for cove mounting?
COMPLIANT 5YEAR
WARRANTY
INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22 1
QUOVA-STANDARD
INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22 22© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22
METHODS OF INSTALLATION
THIN WIDE ROND TORQ
Quova-Standard
WALL
WALL
FLOOR
CEILING
3.20"
1.06"
1.88"
Compatible Fixtures
LALO ARKA VEVE
OPTI VERS
TELA
0.57"
1.00"
.64"
.88"
Cove Mounting Method
• OUOVA-STANDARD (page 4-6)
ATTENTION: Please read all instructions BEFORE installation
Product to be installed by a licensed electrician - Field modifications void warranty
Use only with Class 2 power supply unit — Compatible for use with Q-Tran power supplies
Knife edge cove mount
Input Voltage: 24VDC
Diagrams for representation only and not to scale.
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22 33© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22
COMPONENTS & HARDWARE
NOTES:
STAINLESS STEEL CLIP MAGNET CLIP
2 clips provided for 4’ or less; 4 clips provided for greater than 4’ One magnet clip per foot
MMA-01/MMA-02 comes in 12” pieces; use at least one clip per MMA accessory
MMA-01/MMA-02 can be cut into smaller pieces, if desired
STAINLESS STEEL CLIP
MAGNET CLIP
SST-01 CC-01
.20
"
.81"
1.25"
1.25”
.7”
.18”
MG-01 MG-02
1.25"
.20
"
.20
"
.81"
.21
"
.188"
Included
Stainless Steel
Phillip
#4-40 - X 3/16”
3.20"
1.06"
1.88"
MAGNET MOUNT ACCESSORY
sold individually
MMA-01
Included
• 2 #6x5/8”
Flat Head SS
12"
.75"
.23"
2.5"
.64"
MMA-02
Included
• 2 #6x5/8”
Flat Head SS
1.86”
12”
.64”
.58”
ACCESSORIES SOLD SEPARATELY
2
3
A
B
4
1
5
6
CORNER
Outside Inside
QUOVA-STANDARD
3.13”
A - Fixture Housing
B - Lighting Module
1 - Inside and Outside Corners.
2 - Fixture Mounting Channel.
3 - Mounting Screws, by Others.
4 - Fixture Housing Extrusion - Anodized Aluminum - surface
treated to accept paint. Provided in 8ft nominal lengths.
Field cut final piece in linear run to desired length.
5 - End Cap - Used to close the end of the fixture housing
extrusion. Not required when the fixture housing extrusion
ends in a corner or against a wall. Available in Left and
Right Configurations.
6 - Inline Bracket; Designed to align and hold sections of fixture
housing together.
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22 44© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22
COMPONENTS &
HARDWARE
SURFACE MOUNTING METHOD
SURFACE PREPARATION
Temperature and environmental concerns:
• Ideal application environment is 70-100ºF in 50% humidity
or less.
• Minimum application temperature: 50ºF
• This temperature and humidity should be maintained for
72 hours after application for maximum bond strength.
50% humidity
or less
70-100ºF 72 hrs
METHODS &
INSTALLATIONS MOUNTING
INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22 55© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22
a: Pre-drill 1/4” pilot holes every 16” to align with studs start
with corners and fill in with straight sections..
b: Align QUOVA to be level, and if necessary, to line up with
ceiling/soffit.
c: Mount QUOVA to wall with #6 screws (by others) every 16”
into studs.
a: If multiple lengths are being used, install the inline bracket.
b: Install inline bracket in mounted piece.
c: Follow Instructions of step 1 for second length.
d: Confirm both pieces are level and aligned, mount second
piece, slide inline bracket over and tighten set screws.
e: Repeat for additional lengths as needed.
Install the endcap on the appropriate side and tighten set
screw and repeat on the other side.
a: Determine wire feed location.
b: Drill 1/4” Hole through QUOVA and drywall.
COVE MOUNTING METHOD: QUOVA-STANDARD
LEFT
Front View
ISO View
Front View
ISO View
RIGHT
1
16"
21
3 4
2
a
b
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
Corner
16"
Corner
INSTALLATION INSTRUCTIONS
LINEAR FIXTURE - QUOVA - STANDARD
© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22 66© 2022 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-11-23-22
a: Apply joint compound to wall and underneath.
b: Allow to dry.
c: Sand and repeat as necessary.
d: Once completed, apply primer and paint.
Use drywall tape at joint of QUOVA to wall and underneath.
a: Install mounting clips in screw track.
a&b: Mount Lighting fixture inside of QUOVA. Run wire through
pre-drilled hole back to power supply or junction box.
QUOVA Standard Install Assembly.
COVE MOUNTING METHOD: QUOVA-STANDARD
Dry wall Tape
Bottom View
ISO-Top View
5
7 8
6
Joint Compound
COMPONENTS &
HARDWARE
METHODS &
INSTALLATIONS MOUNTING
With Mounting
Clip installed
With MMA
installed
With MMA
installed
With Mounting
Clip installed
a
b
b
/